The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Water‐Resistant Conformal Hybrid Electrodes for Aquatic Endurable Electrocardiographic Monitoring
Abstract
Underwater vital signs monitoring of respiratory rate, blood pressure, and the heart's status is essential for healthcare and sports management. Real‐time electrocardiography (ECG) monitoring underwater can be one solution for this. However, the current electrodes used for ECGs are not suitable for aquatic applications since they may lose their adhesiveness to skin, stable conductivity, or/and structural stability when immersed into water. Here, the design and fabrication of water‐resistant electrodes to repurpose stretchable electrodes for applications in an aquatic environment are reported. The electrodes are composed of stretchable metal–polymer composite film as the substrate and dopamine‐containing polymer as a coating. The polymer is designed to possess underwater adhesiveness from the dopamine motif, water stability from the main scaffold, and ionic conductivity from the carboxyl groups for signal transmission. Stable underwater conductivity and firm adhesion to skin allow the electrodes to collect reliable ECG signals under various conditions in water. It is shown that wearable devices incorporated with the water‐resistant electrodes can acquire real‐time ECG signals during swimming, which can be used for revealing the heart condition. These water‐resistant electrodes realize underwater detection of ECG signals and can be used for health monitoring and sports management during aquatic activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
A reversible wet/dry adhesive inspired by mussels and geckos
Lee, H., Lee, B. P., & Messersmith, P. B. (2007) · Nature · doi:10.1038/nature05968 · Cited by 2,043
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Self-citationAdaptive synergy between catechol and lysine promotes wet adhesion by surface salt displacement
Maier, G. P., Rapp, M. V., Waite, J. H., Israelachvili, J. N., & Butler, A. (2015) · Science · doi:10.1126/science.aab0556 · Cited by 722
Cui, C., Fan, C., Wu, Y., Xiao, M., Wu, T., Zhang, D., Chen, X., Liu, B., Xu, Z., Qu, B., et al. (2019) · Advanced Materials · doi:10.1002/adma.201905761 · Cited by 542
Self-citationBiomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Self-citationMultifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Bioinspired Underwater Adhesives
Fan, H., & Gong, J. P. (2021) · Advanced Materials · doi:10.1002/adma.202102983 · Cited by 466
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Metadata
- Authors
- Ji, S., Wan, C., Wang, T., Li, Q., Chen, G., Wang, J., Liu, Z., Yang, H., Liu, X., & Chen, X.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2020-05-25
- Volume
- 32
- Issue
- 26
- Pages
- e2001496-e2001496
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3028305674
- Cited by
- 235
- References
- 13
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Water‐Resistant Conformal Hybrid Electrodes for Aquatic Endurable Electrocardiographic Monitoring. https://app.cochat.ai/papers/10.1002/adma.202001496
- The paper
- Ji, S., Wan, C., Wang, T., Li, Q., Chen, G., Wang, J., Liu, Z., Yang, H., Liu, X., & Chen, X. (2020). Water‐Resistant Conformal Hybrid Electrodes for Aquatic Endurable Electrocardiographic Monitoring. Advanced Materials. https://doi.org/10.1002/adma.202001496
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.