The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dynamic indentation on human skin in vivo: ageing effects
Abstract
Background/purpose: Knowledge of the mechanical properties of the human skin is very important for cosmetic and clinical research. Objective and quantitative measurements are essential to compare studies performed by different experimenters in different centres. The aim of this paper is to present a method to measure the viscoelastic properties of human skin in vivo using dynamic indentation. Methods: A complete device to assess the stiffness and damping of skin has been developed. The frequency and strain amplitude range from 10 to 60 Hz and from 1 to 10 μm. Tests on pure elastic inert materials have been performed to validate the device. An in vivo study including dynamic indentation, suction test, hydration measurement and topographic analysis has been performed on 46 subjects aged from 18 to 70 years, divided into three groups. Results: Results on inert materials show the validity of the device developed. The mechanical behaviour of the skin can be described by a Kelvin–Voight model under dynamic indentation. A comparison with a suction test, hydration and topographic measurements shows that the stiffness and the damping measured by dynamic indentation correspond mainly to the natural tense state of the skin on the body due to the dermis. A weak correlation has been found between dynamic indentation and suction parameters. The complex modulus measured by dynamic indentation at 10 Hz frequency stress ranges from 7.2 ± 2.1 kPa for the oldest group to 10.7 ± 2.6 kPa for the youngest group. Conclusion: The device presented gives convincing results. The measurement of stiffness and damping complements the viscoelastic phenomenological parameters of the suction test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delalleau, A., Josse, G., Lagarde, J.-M., Zahouani, H., & Bergheau, J.-M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.001 · Cited by 230
Self-citation
Cited by
Derler, S., & Gerhardt, L.-C. (2012) · Tribology Letters · doi:10.1007/s11249-011-9854-y · Cited by 425
Mechanical properties of human skin in vivo: a comparative evaluation in 300 men and women
Luebberding, S., Krueger, N., & Kerscher, M. (2014) · Skin Research and Technology · doi:10.1111/srt.12094 · Cited by 198
In vitro indentation to determine the mechanical properties of epidermis
Geerligs, M., van Breemen, L., Peters, G., Ackermans, P., Baaijens, F., & Oomens, C. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.015 · Cited by 195
Metadata
- Authors
- Boyer, G., Laquièze, L., Le Bot, A., Laquièze, S., & Zahouani, H.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2009-01-15
- Volume
- 15
- Issue
- 1
- Pages
- 55-67
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2033468829
- Cited by
- 195
- References
- 1
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic indentation on human skin in vivo: ageing effects. https://app.cochat.ai/papers/10.1111/j.1600-0846.2008.00324.x
- The paper
- Boyer, G., Laquièze, L., Le Bot, A., Laquièze, S., & Zahouani, H. (2009). Dynamic indentation on human skin in vivo: ageing effects. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.2008.00324.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.