Transplanting the Highly Sensitized Patient: The Emory Algorithm
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Renal transplant patients sensitized to HLA antigens comprise nearly one-third of the UNOS wait-list and receive 14% of deceased donor (DD) transplants, a rate half that of unsensitized patients. Between 1999 and 2003, we performed 492 adult renal transplants from DD; 120 patients (approximately 25%) had a panel reactive antibody (PRA) of >30%, with nearly half (n = 58) having a PRA of >80%. Our approach is based upon high-resolution solid-phase HLA antibody analysis to identify class I/II antibodies and a 'virtual crossmatch' to predict compatible donor/recipient combinations. Recipients are excluded from the United Network for Organ Sharing match run if donors possess unacceptable antigens. Thus, when sensitized patients appear on the match run, they have a high probability of a negative final crossmatch. Here, we describe our 5-year experience with this approach. Five-year graft survival ranged from 66% to 70% among unsensitized (n = 272), moderately sensitized (PRA < 30%, n = 100) and highly sensitized (>30% PRA; n = 120) patients, equal to the average national graft survival (65.7%). The application of this approach (the Emory Algorithm) provides a logical and systematic approach to improve the access of sensitized patients to DD organs and promote more equitable allocation to a highly disadvantaged group of patients awaiting renal transplantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Significance of the Positive Crossmatch Test in Kidney Transplantation
Patel, R., & Terasaki, P. I. (1969) · New England Journal of Medicine · doi:10.1056/nejm196904032801401 · Cited by 1,508 · cited 3×
“There are several explanations for not achieving 100% predictability such as: (1) solid-phase assays do not provide targets to every known HLA antigen/allele (now >1800); (2) nontraditional HLA antibodies such as those to HLA-DP and DQ-alpha polymorphisms (23,24) could be responsible for an unexpected positive crossma…”
BackgroundInfluentialMontgomery, R. A., Zachary, A. A., Racusen, L. C., Leffell, M. S., King, K. E., Burdick, J., Maley, W. R., & Ratner, L. E. (2000) · Transplantation · doi:10.1097/00007890-200009270-00006 · Cited by 584 · cited 1×
“The principal pharmacological approaches utilize intravenous immunoglobulin ± plasmapheresis as a preemptive tactic to eliminate/inactivate donor-reactive HLA antibodies (3,4).”
BackgroundStegall, M. D., Gloor, J., Winters, J. L., Moore, S. B., & DeGoey, S. (2006) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2005.01178.x · Cited by 428
Pei, R., Lee, J.-H., Shih, N.-J., Chen, M., & Terasaki, P. I. (2003) · Transplantation · doi:10.1097/00007890-200301150-00008 · Cited by 409 · cited 1×
“Importantly, these new technologies permit HLA antibody specificity determination that far exceeds cell-based assays (11,12).”
BackgroundGebel, H. M., Bray, R. A., & Nickerson, P. (2003) · American Journal of Transplantation · doi:10.1046/j.1600-6135.2003.00273.x · Cited by 362 · cited 2×
“Thus, in current practice and depending on the transplant center, a positive crossmatch due to HLA antibodies may be considered a contraindication to transplantation or, at the very least, a risk factor requiring therapeutic intervention preand/or post-transplantation (10).”
BackgroundMethodSelf-citationTrpkov, K., Campbell, P., Pazderka, F., Cockfield, S., Solez, K., & Halloran, P. F. (1996) · Transplantation · doi:10.1097/00007890-199606150-00007 · Cited by 290 · cited 1×
“Complete analysis of this patient’s serum revealed the following HLA antibody specificities: Class I: A1, 11, 23, 24, 25, 26, 29, 33, 34, 66: B8, 13, 38, 39, 44, 45, 49, 50, 51, 52, 53, 57, 58, 62, 63, 70: Class II: DRB1∗04, ∗07, ∗09; DRB4∗01 (DRw53), and DQB1∗02, ∗0301(7), ∗0302(8), ∗0303(9), ∗04, ∗06.”
Jordan, S. C., Vo, A. A., Bunnapradist, S., Toyoda, M., Peng, A., Puliyanda, D. P., Kamil, E. S., & Tyan, D. B. (2003) · Transplantation · doi:10.1097/01.tp.0000080685.31697.fc · Cited by 246
THE FLOW CYTOMETRIC CROSSMATCH
Bray, R. A., Lebeck, L. K., & Gebel, H. M. (1989) · Transplantation · doi:10.1097/00007890-198911000-00022 · Cited by 124 · cited 1×
“established techniques (15) using pretransplant sera from each recipient”
MethodSelf-citationHLA‐DRB101 subtyping by allele‐specific PCR amplification: A sensitive, specific and rapid technique
Olerup, O., & Zetterquist, H. (1991) · Tissue Antigens · doi:10.1111/j.1399-0039.1991.tb01872.x · Cited by 121 · cited 2×
“lyzed on a flow cytometer as described (14).”
BackgroundMethod
Cited by
Costanzo, M. R., Costanzo, M. R., Dipchand, A., Starling, R., Anderson, A., Chan, M., Desai, S., Fedson, S., Fisher, P., Gonzales-Stawinski, G., et al. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.05.034 · Cited by 1,653
Preexisting Donor-Specific HLA Antibodies Predict Outcome in Kidney Transplantation
Lefaucheur, C., Loupy, A., Hill, G. S., Andrade, J., Nochy, D., Antoine, C., Gautreau, C., Charron, D., Glotz, D., & Suberbielle-Boissel, C. (2010) · Journal of the American Society of Nephrology · doi:10.1681/asn.2009101065 · Cited by 789
Tait, B. D., Süsal, C., Gebel, H. M., Nickerson, P. W., Zachary, A. A., Claas, F. H. J., Reed, E. F., Bray, R. A., Campbell, P., Chapman, J. R., et al. (2013) · Transplantation · doi:10.1097/tp.0b013e31827a19cc · Cited by 787
Self-citationCiurea, S. O., de Lima, M., Cano, P., Korbling, M., Giralt, S., Shpall, E. J., Wang, X., Thall, P. F., Champlin, R. E., & Fernandez-Vina, M. (2009) · Transplantation · doi:10.1097/tp.0b013e3181b9d710 · Cited by 287
Amico, P., Hönger, G., Mayr, M., Steiger, J., Hopfer, H., & Schaub, S. (2009) · Transplantation · doi:10.1097/tp.0b013e3181a5e034 · Cited by 258
Reed, E. F., Rao, P., Zhang, Z., Gebel, H., Bray, R. A., Guleria, I., Lunz, J., Mohanakumar, T., Nickerson, P., Tambur, A. R., et al. (2013) · American Journal of Transplantation · doi:10.1111/ajt.12287 · Cited by 245
Self-citationReview article: Luminex technology for HLA antibody detection in organ transplantation
TAIT, B. D., HUDSON, F., CANTWELL, L., BREWIN, G., HOLDSWORTH, R., BENNETT, G., & JOSE, M. (2009) · Nephrology · doi:10.1111/j.1440-1797.2008.01074.x · Cited by 159
Metadata
- Authors
- Bray, R. A., Nolen, J. D. L., Larsen, C., Pearson, T., Newell, K. A., Kokko, K., Guasch, A., Tso, P., Mendel, J. B., & Gebel, H. M.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 6
- Issue
- 10
- Pages
- 2307-2315
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W1988814676
- Cited by
- 216
- References
- 11
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.