A fluorescence energy transfer‐based mechanical stress sensor for specific proteins in situ
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
To measure mechanical stress in real time, we designed a fluorescence resonance energy transfer (FRET) cassette, denoted stFRET, which could be inserted into structural protein hosts. The probe was composed of a green fluorescence protein pair, Cerulean and Venus, linked with a stable α‐helix. We measured the FRET efficiency of the free cassette protein as a function of the length of the linker, the angles of the fluorophores, temperature and urea denaturation, and protease treatment. The linking helix was stable to 80 °C, unfolded in 8 m urea, and rapidly digested by proteases, but in all cases the fluorophores were unaffected. We modified the α‐helix linker by adding and subtracting residues to vary the angles and distance between the donor and acceptor, and assuming that the cassette was a rigid body, we calculated its geometry. We tested the strain sensitivity of stFRET by linking both ends to a rubber sheet subjected to equibiaxial stretch. FRET decreased proportionally to the substrate strain. The naked cassette expressed well in human embryonic kidney‐293 cells and, surprisingly, was concentrated in the nucleus. However, when the cassette was located into host proteins such α‐actinin, nonerythrocyte spectrin and filamin A, the labeled hosts expressed well and distributed normally in cell lines such as 3T3, where they were stressed at the leading edge of migrating cells and relaxed at the trailing edge. When collagen‐19 was labeled near its middle with stFRET, it expressed well in Caenorhabditis elegans , distributing similarly to hosts labeled with a terminal green fluorescent protein, and the worms behaved normally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Stretching DNA with optical tweezers
Wang, M. D., Yin, H., Landick, R., Gelles, J., & Block, S. M. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78780-0 · Cited by 1,481
An improved cyan fluorescent protein variant useful for FRET
Rizzo, M. A., Springer, G. H., Granada, B., & Piston, D. W. (2004) · Nature Biotechnology · doi:10.1038/nbt945 · Cited by 1,077
Magnetic Tweezers: Micromanipulation and Force Measurement at the Molecular Level
Gosse, C., & Croquette, V. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75672-5 · Cited by 954
Quantitative Fluorescence Resonance Energy Transfer Measurements Using Fluorescence Microscopy
Gordon, G. W., Berry, G., Liang, X. H., Levine, B., & Herman, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77976-7 · Cited by 854
Physical plasticity of the nucleus in stem cell differentiation
Pajerowski, J. D., Dahl, K. N., Zhong, F. L., Sammak, P. J., & Discher, D. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702576104 · Cited by 833
Mechanical unfolding intermediates in titin modules
Marszalek, P. E., Lu, H., Li, H., Carrion-Vazquez, M., Oberhauser, A. F., Schulten, K., & Fernandez, J. M. (1999) · Nature · doi:10.1038/47083 · Cited by 798
Sequence-dependent mechanics of single DNA molecules.
Gaub, H. E., Rief, M., & Clausen‐Schaumann, H. (1999) · Nature Structural Biology · doi:10.1038/7582 · Cited by 792
Dale, R. E., Eisinger, J., & Blumberg, W. E. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85243-1 · Cited by 755
Molecular basis of mechanosensory transduction
Gillespie, P. G., & Walker, R. G. (2001) · Nature · doi:10.1038/35093011 · Cited by 706
Cited by
Measuring mechanical tension across vinculin reveals regulation of focal adhesion dynamics
Grashoff, C., Hoffman, B. D., Brenner, M. D., Zhou, R., Parsons, M., Yang, M. T., McLean, M. A., Sligar, S. G., Chen, C. S., Ha, T., et al. (2010) · Nature · doi:10.1038/nature09198 · Cited by 1,541
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Mechanically-Induced Chemical Changes in Polymeric Materials
Caruso, M. M., Davis, D. A., Shen, Q., Odom, S. A., Sottos, N. R., White, S. R., & Moore, J. S. (2009) · Chemical Reviews · doi:10.1021/cr9001353 · Cited by 1,372
Appreciating force and shape—the rise of mechanotransduction in cell biology
Iskratsch, T., Wolfenson, H., & Sheetz, M. P. (2014) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3903 · Cited by 798
Quantifying forces in cell biology
Roca-Cusachs, P., Conte, V., & Trepat, X. (2017) · Nature Cell Biology · doi:10.1038/ncb3564 · Cited by 498
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
Genetically Encodable Fluorescent Biosensors for Tracking Signaling Dynamics in Living Cells
Newman, R. H., Fosbrink, M. D., & Zhang, J. (2011) · Chemical Reviews · doi:10.1021/cr100002u · Cited by 353
Integrins in mechanotransduction
Ross, T. D., Coon, B. G., Yun, S., Baeyens, N., Tanaka, K., Ouyang, M., & Schwartz, M. A. (2013) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2013.05.006 · Cited by 341
Molecular Tension Sensors Report Forces Generated by Single Integrin Molecules in Living Cells
Morimatsu, M., Mekhdjian, A. H., Adhikari, A. S., & Dunn, A. R. (2013) · Nano Letters · doi:10.1021/nl4005145 · Cited by 238
Measuring forces and stresses in situ in living tissues
Sugimura, K., Lenne, P.-F., & Graner, F. (2016) · Development · doi:10.1242/dev.119776 · Cited by 222
“A spring of known stiffness, such as a defined polypeptide sequence, is genetically inserted between donor and acceptor (Meng et al., 2008; Grashoff et al., 2010).”
BackgroundAdvances in Quantum Mechanochemistry: Electronic Structure Methods and Force Analysis
Stauch, T., & Dreuw, A. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00458 · Cited by 214
Cardiac Mechano-Gated Ion Channels and Arrhythmias
Peyronnet, R., Nerbonne, J. M., & Kohl, P. (2016) · Circulation Research · doi:10.1161/circresaha.115.305043 · Cited by 206
“changes in strain, and they can be used in vivo to characterize cytoskeletal tension in real time.(221,277,278) A conceptually”
Mittelheisser, V., Gensbittel, V., Bonati, L., Li, W., Tang, L., & Goetz, J. G. (2024) · Nature Nanotechnology · doi:10.1038/s41565-023-01535-8 · Cited by 109
A paradigm shift: Bioengineering meets mechanobiology towards overcoming remyelination failure
Carvalho, E. D., Morais, M. R. G., Ferreira, H. P., Silva, M. M. C., Guimarães, S. C., & Pêgo, A. P. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121427 · Cited by 16
Metadata
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.