Near‐Infrared Raman Spectroscopy for In Vitro Detection of Cervical Precancers
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
In this study, we investigate the potential of near‐infrared Raman spectroscopy to differentiate cervical precancers from normal tissues, inflammation and metaplasia and to differentially diagnose low‐grade and high‐grade precancers. Near infrared Raman spectra were measured from 36 biopsies from 18 patients in vitro. Detection algorithms were developed and evaluated relative to histopathologic examination. Algorithms based on empirically selected peak intensities, ratios of peak intensities and a combination of principal component analysis for data reduction and Fisher discriminant analysis for classification were investigated. Spectral peaks were tentatively identified from measured spectra of potential chromophores. Empirically selected normalized intensities can differentiate precancers from other tissues with an average sensitivity and specificity of 88 ± 4% and 92 ± 4%. Ratios of un‐normalized intensities can differentiate precancers from other tissues with a sensitivity and specificity of 82% and 88% and high‐grade from low‐grade lesions with a sensitivity and specificity of 100%. Using multivariate methods, intensities at eight frequencies can be used to differentiate precancers from all other tissues with a sensitivity and specificity of 82% and 92% in an unbiased test. Raman algorithms can potentially separate benign abnormalities such as inflammation and metaplasia from precancers. Comparison of tissue spectra to published and measured chromophore spectra indicate that the most likely primary contributors to the tissue spectra are collagen, nucleic acids, phospholipids and glucose 1‐phos‐phate. These results suggest that near‐infrared Raman spectroscopy can be used for cervical precancer diagnosis and may be able to accurately separate samples with inflammation and metaplasia from precancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SEER Cancer Statistics Review, 1975-2003
Ries, L. A. G., Harkins, D., Krapcho, M. F., Mariotto, A. B., Miller, B., Feuer, E. J., Clegg, L. X., Eisner, M. P., Horner, M., Howlader, N., et al. (2006) · Digital Archive @ GSU · Cited by 11,791
The Papanicolaou Test for Cervical Cancer Detection: A Triumph and a Tragedy
Koss, L. G. (1989) · JAMA · doi:10.1001/jama.1989.03420050087046 · Cited by 645
Multivariate Analysis: Methods and Applications
Chatterjee, S., Dillon, W., & Goldstein, M. (1985) · Journal of Business & Economic Statistics · doi:10.2307/1391734 · Cited by 526
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Self-citationFluorescence spectra from cancerous and normal human breast and lung tissues
Alfano, R., Tang, G., Pradhan, A., Lam, W., Choy, D., & Opher, E. (1987) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1987.1073234 · Cited by 347
Ramanujam, N., Mitchell, M. F., Mahadevan, A., Warren, S., Thomsen, S., Silva, E., & Richards-Kortum, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.21.10193 · Cited by 253
Self-citationOrganisation and results of the cervical cytology screening programme in British Columbia, 1955-85
Anderson, G. H., Boyes, D. A., Benedet, J. L., Le Riche, J. C., Matisic, J. P., Suen, K. C., Worth, A. J., Millner, A., & Bennett, O. M. (1988) · BMJ · doi:10.1136/bmj.296.6627.975 · Cited by 229
Ramanujam, N., Mitchell, M. F., Mahadevan‐Jansen, A., Thomson, S. L., Staerkel, G., Malpica, A., Wright, T., Atkinson, N., & Richards‐Kortum, R. (1996) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1996.tb03130.x · Cited by 227
Self-citationMultivariate Interpretation of Clinical Laboratory Data.
Sampson, A. R., Albert, A., & Harris, E. K. (1988) · Journal of the American Statistical Association · doi:10.2307/2288902 · Cited by 136
Rapid Near-Infrared Raman Spectroscopy of Human Tissue with a Spectrograph and CCD Detector
Baraga, J. J., Feld, M. S., & Rava, R. P. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125555 · Cited by 130
Cited by
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Self-citationProspects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Raman spectroscopy for identification of epithelial cancers
Stone, N., Kendall, C., Smith, J., Crow, P., & Barr, H. (2004) · Faraday Discussions · doi:10.1039/b304992b · Cited by 768
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Near‐infrared Raman spectroscopy for the classification of epithelial pre‐cancers and cancers
Stone, N., Kendall, C., Shepherd, N., Crow, P., & Barr, H. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.882 · Cited by 472
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Self-citationMetabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Self-citationVibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Raman Spectroscopy Detects Biochemical Changes Due to Proliferation in Mammalian Cell Cultures
Short, K. W., Carpenter, S., Freyer, J. P., & Mourant, J. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.103.038604 · Cited by 286
Medical applications of Raman spectroscopy: From proof of principle to clinical implementation
Choo‐Smith, L. ‐., Edwards, H. G. M., Endtz, H. P., Kros, J. M., Heule, F., Barr, H., Robinson, J. S., Bruining, H. A., & Puppels, G. J. (2002) · Biopolymers · doi:10.1002/bip.10064 · Cited by 280
Kendall, C., Stone, N., Shepherd, N., Geboes, K., Warren, B., Bennett, R., & Barr, H. (2003) · The Journal of Pathology · doi:10.1002/path.1376 · Cited by 245
Vibrational spectroscopy for cervical cancer pathology, from biochemical analysis to diagnostic tool
Lyng, F. M., Faoláin, E. Ó., Conroy, J., Meade, A. D., Knief, P., Duffy, B., Hunter, M. B., Byrne, J. M., Kelehan, P., & Byrne, H. J. (2007) · Experimental and Molecular Pathology · doi:10.1016/j.yexmp.2007.01.001 · Cited by 230
“…have shown that Fourier Transform Infra Red (FTIR) spectroscopy (Wood et al 2003, Mordechai et al 2004, Romeo et al 2004) or Raman spectroscopy (Mahadevan-Jansen et al 1998, Utzinger et al 2001, Ó Faoláin et al 2005) can be used for detecting spectral changes in malignant and pre-malignant…”
Ó Faoláin, E., Hunter, M. B., Byrne, J. M., Kelehan, P., McNamara, M., Byrne, H. J., & Lyng, F. M. (2005) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2005.02.013 · Cited by 227
Abramczyk, H., Surmacki, J., Kopeć, M., Olejnik, A. K., Lubecka-Pietruszewska, K., & Fabianowska-Majewska, K. (2015) · The Analyst · doi:10.1039/c4an01875c · Cited by 220
In Vivo Detection of Dysplastic Tissue by Raman Spectroscopy
Bakker Schut, T. C., Witjes, M. J. H., Sterenborg, H. J. C. M., Speelman, O. C., Roodenburg, J. L. N., Marple, E. T., Bruining, H. A., & Puppels, G. J. (2000) · Analytical Chemistry · doi:10.1021/ac000780u · Cited by 194
The use of Raman spectroscopy to identify and grade prostatic adenocarcinoma in vitro
Crow, P., Stone, N., Kendall, C. A., Uff, J. S., Farmer, J. A. M., Barr, H., & Wright, M. P. J. (2003) · British Journal of Cancer · doi:10.1038/sj.bjc.6601059 · Cited by 189
“…& 2003 Cancer Research UK Keywords: prostate cancer; benign prostatic hypertrophy; Raman spectroscopy; Gleason score Raman spectroscopy is an optical technique that utilises molecular-specific, inelastic scattering of light photons to interrogate biological tissues (Mahadevan-Jansen et al, 1998).”
BackgroundAdvances in the clinical application of Raman spectroscopy for cancer diagnostics
Kallaway, C., Almond, L. M., Barr, H., Wood, J., Hutchings, J., Kendall, C., & Stone, N. (2013) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2013.01.008 · Cited by 186
Erzina, M., Trelin, A., Guselnikova, O., Dvorankova, B., Strnadova, K., Perminova, A., Ulbrich, P., Mares, D., Jerabek, V., Elashnikov, R., et al. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.127660 · Cited by 116
Metadata
- Authors
- Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujamf, N., Malpica, A., Thomsen, S., Utzinger, U., & Richards‐Kortumt, R.
- Venue
- Photochemistry and Photobiology
- Publisher
- Wiley
- Published
- 1998-07
- Volume
- 68
- Issue
- 1
- Pages
- 123-132
- ISSN
- 0031-8655 (ISSN-L)
- 1751-1097
- OpenAlex
- W2092060883
- Cited by
- 282
- References
- 14
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.