The IOP‐IOL: A probe into the eye
The DOI matches its Crossref record.
Abstract
The intraocular lens (IOL) implant can be looked upon as a probe into the space of the eye. Adapting that view, it is logical to furnish the IOL‐probe with biomedical sensors that would explore its environment. A sensor is presented for continuous monitoring of intraocular pressure (IOP), incorporated in the haptics of an IOL. The sensor consists of a capacitative spiral circuit, needing no energy, correlating its resonance frequency to the actual IOP. This resonance frequency is remotely and non‐invasively detected by an external device located in a spectacle frame.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0015 · Cited by 244
Mansouri, K., & Shaarawy, T. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.192922 · Cited by 232
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Laukhin, V., Sánchez, I., Moya, A., Laukhina, E., Martin, R., Ussa, F., Rovira, C., Guimera, A., Villa, R., Aguiló, J., et al. (2011) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.05.021 · Cited by 57
Metadata
- Authors
- Svedbergh, B., Bäcklund, Y., Hök, B., & Rosengren, L.
- Venue
- Acta Ophthalmologica
- Publisher
- Wiley
- Published
- 1992-04
- Volume
- 70
- Issue
- 2
- Pages
- 266-268
- ISSN
- 0001-639X (ISSN-L)
- 1755-375X
- 1755-3768
- OpenAlex
- W2026934904
- Cited by
- 38
- References
- 0
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The IOP‐IOL: A probe into the eye. https://app.cochat.ai/papers/10.1111/j.1755-3768.1992.tb04135.x
- The paper
- Svedbergh, B., Bäcklund, Y., Hök, B., & Rosengren, L. (1992). The IOP‐IOL: A probe into the eye. Acta Ophthalmologica. https://doi.org/10.1111/j.1755-3768.1992.tb04135.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.