The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
International clinical harmonization of glycated hemoglobin in Japan: From Japan Diabetes Society to National Glycohemoglobin Standardization Program values
Open accessAbstract
In 1999, the Japan Diabetes Society (JDS) launched the previous version of the diagnostic criteria of diabetes mellitus, in which JDS took initiative in adopting glycated hemoglobin (HbA1c) as an adjunct to the diagnosis of diabetes. In contrast, in 2009 the International Expert Committee composed of the members of the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) manifested the recommendation regarding the use of HbA1c in diagnosing diabetes mellitus as an alternative to glucose measurements based on the updated evidence showing that HbA1c has several advantages as a marker of chronic hyperglycemia2–4. The JDS extensively evaluated the usefulness and feasibility of more extended use of HbA1c in the diagnosis of diabetes based on Japanese epidemiological data, and then the ‘Report of the Committee on the Classification and Diagnostic Criteria of Diabetes Mellitus’ was published in the Journal of Diabetes Investigation5 and Diabetology International6. The new diagnostic criterion in Japan came into effect on 1 July 2010. According to the new version of the criteria, HbA1c (JDS) ≥6.1% is now considered to indicate a diabetic type, but the previous diagnosis criteria of high plasma glucose (PG) levels to diagnose diabetes mellitus also need to be confirmed. Those are as follows: (i) FPG ≥126 mg/dL (7.0 mmol/L); (ii) 2-h PG ≥200 mg/dL (11.1 mmol/L) during an oral glucose tolerance test; or (iii) casual PG ≥200 mg/dL (11.1 mmol/L). If both PG criteria and HbA1c in patients have met the diabetic type, those patients are immediately diagnosed to have diabetes mellitus5,6. In the report, the HbA1c measurements in Japan are well calibrated with Japanese-Clinical-Laboratory-Use Certified Reference Material (JCCRM). The certified values are determined by a high-resolution type ion-exchange high performance liquid chromatography (HPLC) (KO 500 method) and certified using the designated comparison method (DCM) of the Japan Society of Clinical Chemistry (JSCC) and the JDS. After incorporating a proportional bias correction to the value anchored to the peptide mapping method of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), the DCM actually measures β-N-mono-deoxyfructosyl hemoglobin and has an intercept approximately equal to zero against the peptide mapping method of IFCC in measuring fresh raw human blood samples. Furthermore, standardization of HbA1c in Japan was initiated in 1993, and the serial reference materials from JDS Lot 1 to JDS Lot 4 are well certified using the DCM until now. In the new diagnosis criteria5,6, the new cut-point of HbA1c (JDS) for diagnosis of diabetes mellitus is 6.1%, which is equivalent to the internationally-used HbA1c (National Glycohemoglobin Standardization Program [NGSP]) 6.5%, as HbA1c (NGSP)(%) is reported to be equivalent to 1.019 × HbA1c (JDS)% + 0.3%, which is reasonably estimated by the equation of HbA1c (JDS)% + 0.4%, as the difference between the two equations is within error of HbA1c measurements (2∼3%). However, on 1 October 2011, the Reference Material Institute for Clinical Chemistry Standards (ReCCS, Kanagawa, Japan) was certified as an Asian Secondary Reference Laboratory (ASRL) using the KO 500 method and the reference materials JCCRM411-2 (JDS Lot 4) after successful completion of NGSP network laboratory certification. Therefore, the HbA1c unit is now traceable to the Diabetes Control and Complications Trial (DCCT) reference method. The comparison was carried out with the Central Primary Reference Laboratory (CPRL) in the University of Missouri School of Medicine. The conversion equation from HbA1c (JDS) to HbA1c (NGSP) units is officially certified as follows: NGSP (%) = 1.02 × JDS (%) + 0.25%; conversely, JDS (%) = 0.980 × NGSP (%) – 0.245%. Based on this equation, in the range of JDS values ≤4.9%, NGSP (%) = JDS (%) + 0.3%; in the range of JDS 5.0∼9.9%, NGSP (%) = JDS (%) + 0.4%; and in the range of JDS 10∼14.9%, NGSP (%) = JDS (%) + 0.5%. These results show that the previous equation of NGSP (%) = JDS (%) + 0.4% is also confirmed in the present equation, considering a 2∼3% error of HbA1c measurements. The council meeting of the JDS finally decided to use HbA1c (NGSP) values in clinical practice from 1 April 2012, although HbA1c (JDS) values will be included until people become familiar with the new expression. Finally, it is also important to emphasize that the new HbA1c (NGSP) values can be directly measured and printed out from 1 April 2012. However, both new diagnostic reference values and target values of glycemic control have been adjusted to those equivalent values of HbA1c (JDS), as shown in the Table 1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toprak, O., Kurt, H., Sarı, Y., Şarkış, C., Us, H., & Kırık, A. (2017) · Kidney and Blood Pressure Research · doi:10.1159/000468530 · Cited by 29,627
Diagnosis and Classification of Diabetes Mellitus
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s062 · Cited by 13,988
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s062 · Cited by 5,491
International Expert Committee report on the role of the A1c assay in the diagnosis of diabetes
The International Expert Committee (2009) · Diabetes Care · doi:10.2337/dc09-9033 · Cited by 3,185
Report of the Committee on the Classification and Diagnostic Criteria of Diabetes Mellitus
The Committee of the Japan Diabetes Society on the Diagnostic Criteria of Diabetes Mellitus, Seino, Y., Nanjo, K., Tajima, N., Kadowaki, T., Kashiwagi, A., Araki, E., Ito, C., Inagaki, N., Iwamoto, Y., et al. (2010) · Journal of Diabetes Investigation · doi:10.1111/j.2040-1124.2010.00074.x · Cited by 1,772
Self-citationCowie, C. C., Rust, K. F., Byrd-Holt, D. D., Gregg, E. W., Ford, E. S., Geiss, L. S., Bainbridge, K. E., & Fradkin, J. E. (2010) · Diabetes Care · doi:10.2337/dc09-1524 · Cited by 689
Seino, Y., Nanjo, K., Tajima, N., Kadowaki, T., Kashiwagi, A., Araki, E., Ito, C., Inagaki, N., Iwamoto, Y., Kasuga, M., et al. (2010) · Diabetology International · doi:10.1007/s13340-010-0006-7 · Cited by 614
Self-citationUse of glycated haemoglobin (HbA1c) in the diagnosis of diabetes mellitus
(2011) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.03.012 · Cited by 455
The Committee of the Japan Diabetes Society on the Diagnostic Criteria of Diabetes Mellitus
Seino, Y. (2010) · Medical Entomology and Zoology · Cited by 319
Cited by
Diabetes mellitus and risk of dementia: A meta‐analysis of prospective observational studies
Gudala, K., Bansal, D., Schifano, F., & Bhansali, A. (2013) · Journal of Diabetes Investigation · doi:10.1111/jdi.12087 · Cited by 727
Adachi, M., Yamaoka, K., Watanabe, M., Nishikawa, M., Kobayashi, I., Hida, E., & Tango, T. (2013) · BMC Public Health · doi:10.1186/1471-2458-13-467 · Cited by 57
Kadota, A., Miura, K., Okamura, T., Fujiyoshi, A., Ohkubo, T., Kadowaki, T., Takashima, N., Hisamatsu, T., Nakamura, Y., Kasagi, F., et al. (2013) · Journal of Atherosclerosis and Thrombosis · doi:10.5551/jat.17244 · Cited by 51
Self-citationSakaguchi, K., Hirota, Y., Hashimoto, N., Ogawa, W., Hamaguchi, T., Matsuo, T., Miyagawa, J.-I., Namba, M., Sato, T., Okada, S., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700313 · Cited by 50
Self-citationHeianza, Y., Arase, Y., Saito, K., Tsuji, H., Fujihara, K., Hsieh, S. D., Kodama, S., Shimano, H., Yamada, N., Hara, S., et al. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.112.043364 · Cited by 46
Metadata
- Authors
- Kashiwagi, A., Kasuga, M., Araki, E., Oka, Y., Hanafusa, T., Ito, H., Tominaga, M., Oikawa, S., Noda, M., Kawamura, T., Sanke, T., Namba, M., Hashiramoto, M., Sasahara, T., Nishio, Y., Kuwa, K., Ueki, K., Takei, I., Umemoto, M., Murakami, M., Yamakado, M., Yatomi, Y., Ohashi, H., & Committee on the Standardization of Diabetes Mellitus‐Related Laboratory Testing of Japan Diabetes Society
- Venue
- Journal of Diabetes Investigation
- Publisher
- Wiley
- Published
- 2012-02
- Volume
- 3
- Issue
- 1
- Pages
- 39-40
- ISSN
- 2040-1116 (ISSN-L)
- 2040-1124
- OpenAlex
- W2150568560
- Cited by
- 901
- References
- 9
- FWCI
- 100.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: International clinical harmonization of glycated hemoglobin in Japan: From Japan Diabetes Society to National Glycohemoglobin Standardization Program values. https://app.cochat.ai/papers/10.1111/j.2040-1124.2012.00207.x
- The paper
- Kashiwagi, A., Kasuga, M., Araki, E., Oka, Y., Hanafusa, T., Ito, H., Tominaga, M., Oikawa, S., Noda, M., Kawamura, T., Sanke, T., Namba, M., Hashiramoto, M., Sasahara, T., Nishio, Y., Kuwa, K., Ueki, K., Takei, I., Umemoto, M., . . . Committee on the Standardization of Diabetes Mellitus‐Related Laboratory Testing of Japan Diabetes Society. (2012). International clinical harmonization of glycated hemoglobin in Japan: From Japan Diabetes Society to National Glycohemoglobin Standardization Program values. Journal of Diabetes Investigation. https://doi.org/10.1111/j.2040-1124.2012.00207.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.