Assessing Arrhythmia Burden After Catheter Ablation of Atrial Fibrillation Using an Implantable Loop Recorder: The ABACUS Study
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Assessing Arrhythmia Burden After Ablation: Introduction: Arrhythmia monitoring in patients undergoing atrial fibrillation (AF) ablation is challenging. Transtelephonic monitors (TTMs) are cumbersome to use and provide limited temporal assessment. Implantable loop recorders (ILRs) may overcome these limitations. We sought to evaluate the utility of ILRs versus conventional monitoring (CM) in patients undergoing AF ablation. Methods and Results: Forty‐four patients undergoing AF ablation received ILRs and CM (30‐day TTM at discharge and months 5 and 11 postablation). Over the initial 6 months, clinical decisions were made based on CM. Subjects were then randomized for the remaining 6 months to arrhythmia assessment and management by ILR versus CM. The primary endpoint was arrhythmia recurrence. The secondary endpoint was actionable clinical events (change of antiarrhythmic drugs [AADs], anticoagulation, non‐AF arrhythmia events, etc.) due to either monitoring strategy. Over the study period, 6 patients withdrew. In the first 6 months, AF recurred in 18 patients (7 noted by CM, 18 by ILR; P = 0.002). Five patients in the CM (28%) and 5 in the ILR arm (25%; P = NS) had AF recurrence during the latter 6 months. AF was falsely diagnosed frequently by ILR (730 of 1,421 episodes; 51%). In more patients in the ILR compared with the CM arm, rate control agents (60% vs 39%, P = 0.02) and AADs (71% vs 44%, P = 0.04) were discontinued. Conclusion: In AF ablation patients, ILR can detect more arrhythmias than CM. However, false detection remains a challenge. With adequate oversight, ILRs may be useful in monitoring these patients after ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 2×
“Secondary study endpoints comprised “actionable events” that were defined as recordings made by ILR and not CM that resulted in change of clinical care and these included (1) initiation and/or withdrawal of antiarrhythmic drugs or atrioventricular nodal (AVN) blocking agents, (2) cardioversion, (3) discontinuation or…”
MethodResultCalkins, H., Reynolds, M. R., Spector, P., Sondhi, M., Xu, Y., Martin, A., Williams, C. J., & Sledge, I. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.824789 · Cited by 847 · cited 2×
“Secondary study endpoints comprised “actionable events” that were defined as recordings made by ILR and not CM that resulted in change of clinical care and these included (1) initiation and/or withdrawal of antiarrhythmic drugs or atrioventricular nodal (AVN) blocking agents, (2) cardioversion, (3) discontinuation or…”
MethodResultHindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Charitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
Cost implications of testing strategy in patients with syncope
Krahn, A. D., Klein, G. J., Yee, R., Hoch, J. S., & Skanes, A. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00659-4 · Cited by 170
Effectiveness of remote monitoring in the management of syncope and palpitations
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., & Brignole, M. (2011) · Europace · doi:10.1093/europace/euq503 · Cited by 57
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citation2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Self-citationSanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., Di Bacco, M., Maus, B., & Dekker, L. R. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.03.005 · Cited by 162
Veltmann, C., Bosch, R., Boer, J., Endres, M., Frankenstein, L., Gröschel, K., Hansen, C., & Straube, F. (2023) · Die Kardiologie · doi:10.1007/s12181-023-00634-z · Cited by 3
Jilek, C., & Lewalter, T. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00705-8 · Cited by 1
Metadata
- Authors
- KAPA, S., EPSTEIN, A. E., CALLANS, D. J., GARCIA, F. C., LIN, D., BALA, R., RILEY, M. P., HUTCHINSON, M. D., GERSTENFELD, E. P., TZOU, W., MARCHLINSKI, F. E., FRANKEL, D. S., COOPER, J. M., SUPPLE, G., DEO, R., VERDINO, R. J., PATEL, V. V., & DIXIT, S.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2013-04-11
- Volume
- 24
- Issue
- 8
- Pages
- 875-881
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1485439346
- Cited by
- 107
- References
- 7
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.