CoChat

Assessing Arrhythmia Burden After Catheter Ablation of Atrial Fibrillation Using an Implantable Loop Recorder: The ABACUS Study

KAPA, SURAJ, EPSTEIN, ANDREW E., CALLANS, DAVID J., GARCIA, FERMIN C., LIN, DAVID, BALA, RUPA, RILEY, MICHAEL P., HUTCHINSON, MATHEW D., GERSTENFELD, EDWARD P., TZOU, WENDY, MARCHLINSKI, FRANCIS E., FRANKEL, DAVID S., COOPER, JOSHUA M., SUPPLE, GREGORY, DEO, RAJAT, VERDINO, RALPH J., PATEL, VICKAS V., DIXIT, SANJAY · 2013 · Journal of Cardiovascular Electrophysiology
Cited by 107

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Assessing Arrhythmia Burden After Ablation: Introduction: Arrhythmia monitoring in patients undergoing atrial fibrillation (AF) ablation is challenging. Transtelephonic monitors (TTMs) are cumbersome to use and provide limited temporal assessment. Implantable loop recorders (ILRs) may overcome these limitations. We sought to evaluate the utility of ILRs versus conventional monitoring (CM) in patients undergoing AF ablation. Methods and Results: Forty‐four patients undergoing AF ablation received ILRs and CM (30‐day TTM at discharge and months 5 and 11 postablation). Over the initial 6 months, clinical decisions were made based on CM. Subjects were then randomized for the remaining 6 months to arrhythmia assessment and management by ILR versus CM. The primary endpoint was arrhythmia recurrence. The secondary endpoint was actionable clinical events (change of antiarrhythmic drugs [AADs], anticoagulation, non‐AF arrhythmia events, etc.) due to either monitoring strategy. Over the study period, 6 patients withdrew. In the first 6 months, AF recurred in 18 patients (7 noted by CM, 18 by ILR; P = 0.002). Five patients in the CM (28%) and 5 in the ILR arm (25%; P = NS) had AF recurrence during the latter 6 months. AF was falsely diagnosed frequently by ILR (730 of 1,421 episodes; 51%). In more patients in the ILR compared with the CM arm, rate control agents (60% vs 39%, P = 0.02) and AADs (71% vs 44%, P = 0.04) were discontinued. Conclusion: In AF ablation patients, ILR can detect more arrhythmias than CM. However, false detection remains a challenge. With adequate oversight, ILRs may be useful in monitoring these patients after ablation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jce.12141

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 107

Metadata

Authors
KAPA, S., EPSTEIN, A. E., CALLANS, D. J., GARCIA, F. C., LIN, D., BALA, R., RILEY, M. P., HUTCHINSON, M. D., GERSTENFELD, E. P., TZOU, W., MARCHLINSKI, F. E., FRANKEL, D. S., COOPER, J. M., SUPPLE, G., DEO, R., VERDINO, R. J., PATEL, V. V., & DIXIT, S.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2013-04-11
Volume
24
Issue
8
Pages
875-881
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W1485439346
Cited by
107
References
7
FWCI
8.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.