Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 196

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Prospective validation of a deep learning electrocardiogram algorithm for the detection of left ventricular systolic dysfunction

Attia, Zachi I., Kapa, Suraj, Yao, Xiaoxi, Lopez‐Jimenez, Francisco, Mohan, Tarun L., Pellikka, Patricia A., Carter, Rickey E., Shah, Nilay D., Friedman, Paul A., Noseworthy, Peter A. · 2019 · Journal of Cardiovascular Electrophysiology

Abstract

Objectives: We sought to validate a deep learning algorithm designed to predict an ejection fraction (EF) less than or equal to 35% based on the 12‐lead electrocardiogram (ECG) in a large prospective cohort. Background: Patients undergoing routine ECG may have undetected left ventricular (LV) dysfunction that warrants further echocardiographic assessment. However, identification of these patients can be challenging. Methods: We applied the algorithm to all ECGs interpreted by the Mayo Clinic ECG laboratory in September 2018. The performance of the algorithm was tested among patients with recent echocardiographic assessments of LV function. We also applied the algorithm in patients with no recent echocardiographic assessments of LV function to determine the rate of new “positive screens.” Results: Among 16 056 adult patients who underwent routine ECG, 8600 (age 67.1 ± 15.2 years, 45.6% male), had a transthoracic echocardiogram (TTE) and 3874 patients had a TTE and ECG less than 1 month apart. Among these patients, the algorithm was able to detect an EF less than or equal to 35% with 86.8% specificity, 82.5% sensitivity, and 86.5% accuracy, (area under the curve, 0.918). Among 474 “false‐positives screens,” 189 (39.8%) had an EF of 36% to 50%. Among patients with no prior TTE, the algorithm identified 3.5% of the patients with suspected EF less than or equal to 35%. Exploratory analysis suggests false positives could be reduced by assessing NT‐pro‐BNP after the initial “positive screen.” Conclusions: A deep learning algorithm detected depressed LV function with good accuracy in routine practice. Further studies are needed to validate the algorithm in patients with no prior echocardiogram and to assess the impact on echocardiography utilization, cost, and clinical outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jce.13889

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Attia, Z. I., Kapa, S., Yao, X., Lopez‐Jimenez, F., Mohan, T. L., Pellikka, P. A., Carter, R. E., Shah, N. D., Friedman, P. A., & Noseworthy, P. A.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2019-03-10
Volume
30
Issue
5
Pages
668-674
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2919098904
Cited by
196
References
5
FWCI
11.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.