Home blood pressure control status in 2017‐2018 for hypertension specialist centers in Asia: Results of the Asia BP@Home study
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A self‐measured home blood pressure (BP)‐guided strategy is an effective practical approach to hypertension management. The Asia BP@Home study is the first designed to investigate current home BP control status in different Asian countries/regions using standardized home BP measurements taken with the same validated home BP monitoring device with data memory. We enrolled 1443 medicated hypertensive patients from 15 Asian specialist centers in 11 countries/regions between April 2017 and March 2018. BP was relatively well controlled in 68.2% of patients using a morning home systolic BP (SBP) cutoff of <135 mm Hg, and in 55.1% of patients using a clinic SBP cutoff of <140 mm Hg. When cutoff values were changed to the 2017 AHA/ACC threshold (SBP <130 mm Hg), 53.6% of patients were well controlled for morning home SBP. Using clinic 140 mm Hg and morning home 135 mm Hg SBP thresholds, the proportion of patients with well‐controlled hypertension (46%) was higher than for uncontrolled sustained (22%), white‐coat (23%), and masked uncontrolled (9%) hypertension, with significant country/regional differences. Home BP variability in Asian countries was high, and varied by country/region. In conclusion, the Asia BP@Home study demonstrated that home BP is relatively well controlled at hypertension specialist centers in Asia. However, almost half of patients remain uncontrolled for morning BP according to new guidelines, with significant country/regional differences. Strict home BP control should be beneficial in Asian populations. The findings of this study are important to facilitate development of health policies focused on reducing cardiovascular complications in Asia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality
Banegas, J. R., Ruilope, L. M., de la Sierra, A., Vinyoles, E., Gorostidi, M., de la Cruz, J. J., Ruiz-Hurtado, G., Segura, J., Rodríguez-Artalejo, F., & Williams, B. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1712231 · Cited by 490
RetractedWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationThe Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2014)
(2014) · Hypertension Research · doi:10.1038/hr.2014.20 · Cited by 1,049
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Niiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.149336 · Cited by 390
Johansson, J. K., Niiranen, T. J., Puukka, P. J., & Jula, A. M. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.178657 · Cited by 240
on behalf of Hypertension Objective Treatment Based on Measurement by Electrical Devices of Blood Pressure (HOMED-BP) investigators, Asayama, K., Ohkubo, T., Metoki, H., Obara, T., Inoue, R., Kikuya, M., Thijs, L., Staessen, J. A., & Imai, Y. (2012) · Hypertension Research · doi:10.1038/hr.2012.125 · Cited by 186
Coleman, A., Freeman, P., Steel, S., & Shennan, A. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000189788.05736.5f · Cited by 179
Cited by
Kuwabara, M., Harada, K., Hishiki, Y., & Kario, K. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13499 · Cited by 140
Self-citationEmergence of Home Blood Pressure-Guided Management of Hypertension Based on Global Evidence
Kario, K., Shimbo, D., Hoshide, S., Wang, J.-G., Asayama, K., Ohkubo, T., Imai, Y., McManus, R. J., Kollias, A., Niiranen, T. J., et al. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12630 · Cited by 82
Self-citationLatest hypertension research to inform clinical practice in Asia
Kario, K., Mogi, M., & Hoshide, S. (2022) · Hypertension Research · doi:10.1038/s41440-022-00874-8 · Cited by 32
Self-citation
Metadata
- Authors
- Kario, K., Tomitani, N., Buranakitjaroen, P., Chia, Y., Park, S., Chen, C., Divinagracia, R., Shin, J., Siddique, S., Sison, J., Ann Soenarta, A., Sogunuru, G. P., Tay, J. C., Turana, Y., Zhang, Y., Nailes, J., Wanthong, S., Hoshide, S., Matsushita, N., Kanegae, H., Wang, J., & HOPE Asia Network
- Venue
- The Journal of Clinical Hypertension
- Publisher
- Wiley
- Published
- 2018-11-16
- Volume
- 20
- Issue
- 12
- Pages
- 1686-1695
- ISSN
- 1524-6175 (ISSN-L)
- 1751-7176
- OpenAlex
- W2901476808
- Cited by
- 65
- References
- 18
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.