Flow cytometric analysis of extracellular vesicle subsets in plasma: impact of swarm by particles of non‐interest
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Essentials Extracellular vesicles (EVs) in biological fluids are promising biomarkers for disease. Fluorescence-based flow cytometric analysis is suitable to detect low abundant EV subsets. Particles of non-interest can induce false-positive light scatter and fluorescent signals. Interference of particles of non-interest can be monitored by analyzing serial dilutions. SUMMARY: Background Extracellular vesicles (EVs) in plasma are increasingly being recognized as potential biomarkers. EV analysis for diagnostic purposes should be robust and should allow analysis of EV subsets with a wide range of abundance and in a large number of patient samples. Flow cytometry offers possibilities to meet these criteria, as it allows multiparameter analysis of individual EVs. However, analysis of plasma EVs is challenging, because of their size and heterogeneity, and the presence of other submicrometer-sized particles in plasma that could interfere with EV analysis. Objectives To explore whether fluorescence-based flow cytometric analysis of EV subsets is suitable when the EVs of interest are present in low abundance in a background of non-labeled or differently labeled EVs and particles. Methods Fluorescently labeled EVs of interest were spiked at different ratios in full plasma, purified plasma components, or (non-)fluorescent polystyrene beads, and subsequently analyzed by flow cytometry with fluorescence threshold triggering. Results We found that light scatter detection of low-abundance or rare EV subsets during fluorescence threshold triggering was severely affected by particles of non-interest, owing to coincidence and swarming. Importantly, we show that interfering particles labeled with different fluorophores induced false-positive fluorescent signals on the particles of interest. These unwanted effects could only be discerned and controlled by performing serial dilutions and analyzing light scatter and fluorescence parameters. Conclusions We demonstrate how particles of non-interest in plasma can impact on the light scatter and fluorescence detection of low-abundance EVs of interest during fluorescence-based flow cytometric analysis, and provide a means to prevent erroneous data interpretation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biological properties of extracellular vesicles and their physiological functions
Yáñez‐Mó, M., Siljander, P. R. ‐., Andreu, Z., Bedina Zavec, A., Borràs, F. E., Buzas, E. I., Buzas, K., Casal, E., Cappello, F., Carvalho, J., et al. (2015) · Journal of Extracellular Vesicles · doi:10.3402/jev.v4.27066 · Cited by 5,926
Self-citationExtracellular vesicles: biology and emerging therapeutic opportunities
EL Andaloussi, S., Mäger, I., Breakefield, X. O., & Wood, M. J. A. (2013) · Nature Reviews Drug Discovery · doi:10.1038/nrd3978 · Cited by 3,571
Communication by Extracellular Vesicles: Where We Are and Where We Need to Go
Tkach, M., & Théry, C. (2016) · Cell · doi:10.1016/j.cell.2016.01.043 · Cited by 3,444
Cited by
Théry, C., Witwer, K. W., Aikawa, E., Alcaraz, M. J., Anderson, J. D., Andriantsitohaina, R., Antoniou, A., Arab, T., Archer, F., Atkin‐Smith, G. K., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1535750 · Cited by 11,099
“The method of volume determination in flow cytometry should be reported and potential swarming/coincidence artefacts controlled for [179]; a more detailed guideline article on specifics of flow cytometry analysis of EVs is in preparation by members of ISEV, ISCT and ISAC.”
Self-citationExosome Processing and Characterization Approaches for Research and Technology Development
Lai, J. J., Chau, Z. L., Chen, S., Hill, J. J., Korpany, K. V., Liang, N., Lin, L., Lin, Y., Liu, J. K., Liu, Y., et al. (2022) · Advanced Science · doi:10.1002/advs.202103222 · Cited by 623
Welsh, J. A., Van Der Pol, E., Arkesteijn, G. J. A., Bremer, M., Brisson, A., Coumans, F., Dignat‐George, F., Duggan, E., Ghiran, I., Giebel, B., et al. (2020) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2020.1713526 · Cited by 481
Self-citationExtracellular vesicle isolation methods: rising impact of size-exclusion chromatography
Monguió-Tortajada, M., Gálvez-Montón, C., Bayes-Genis, A., Roura, S., & Borràs, F. E. (2019) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-019-03071-y · Cited by 438
Extracellular Vesicle Quantification and Characterization: Common Methods and Emerging Approaches
Hartjes, T. A., Mytnyk, S., Jenster, G. W., van Steijn, V., & van Royen, M. E. (2019) · Bioengineering · doi:10.3390/bioengineering6010007 · Cited by 342
Russell, A. E., Sneider, A., Witwer, K. W., Bergese, P., Bhattacharyya, S. N., Cocks, A., Cocucci, E., Erdbrügger, U., Falcon‐Perez, J. M., Freeman, D. W., et al. (2019) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2019.1684862 · Cited by 255
Self-citationElucidating Methods for Isolation and Quantification of Exosomes: A Review
Kurian, T. K., Banik, S., Gopal, D., Chakrabarti, S., & Mazumder, N. (2021) · Molecular Biotechnology · doi:10.1007/s12033-021-00300-3 · Cited by 201
Davidson, S. M., Boulanger, C. M., Aikawa, E., Badimon, L., Barile, L., Binder, C. J., Brisson, A., Buzas, E., Emanueli, C., Jansen, F., et al. (2023) · Cardiovascular Research · doi:10.1093/cvr/cvac031 · Cited by 173
Self-citationLozano‐Andrés, E., Enciso‐Martinez, A., Gijsbers, A., Ridolfi, A., Van Niel, G., Libregts, S. F. W. M., Pinheiro, C., van Herwijnen, M. J. C., Hendrix, A., Brucale, M., et al. (2023) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12376 · Cited by 56
“Interestingly, the LDL sample, and to a lesser extent the VLDL sample, showed a characteristic tail with increasing fluorescence, rw-FSC and SSC signals (Figure 1b, bottom and middle left panels), which can be generated by ‘swarming’ [37, 38] or by the presence of multi-particle LPP complexes.”
BackgroundSelf-citation
Metadata
- Authors
- Libregts, S. F. W. M., Arkesteijn, G. J. A., Németh, A., Nolte‐’t Hoen, E. N. M., & Wauben, M. H. M.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 16
- Issue
- 7
- Pages
- 1423-1436
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W2807926135
- Cited by
- 93
- References
- 3
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.