CoChat

Robust and Fragile Aspects of Cortical Blood Flow in Relation to the Underlying Angioarchitecture

Open access
Shih, Andy Y., Rühlmann, Charlotta, Blinder, Pablo, Devor, Anna, Drew, Patrick J., Friedman, Beth, Knutsen, Per M., Lyden, Patrick D., Matéo, Céline, Mellander, Lisa, Nishimura, Nozomi, Schaffer, Chris B., Tsai, Philbert S., Kleinfeld, David · 2015 · Microcirculation
Cited by 93

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

We review the organizational principles of the cortical vasculature and the underlying patterns of blood flow under normal conditions and in response to occlusion of single vessels. The cortex is sourced by a two‐dimensional network of pial arterioles that feeds a three‐dimensional network of subsurface microvessels in close proximity to neurons and glia. Blood flow within the surface and subsurface networks is largely insensitive to occlusion of a single vessel within either network. However, the penetrating arterioles that connect the pial network to the subsurface network are bottlenecks to flow; occlusion of even a single penetrating arteriole results in the death of a 500 μ m diameter cylinder of cortical tissue despite the potential for collateral flow through microvessels. This pattern of flow is consistent with that calculated from a full reconstruction of the angioarchitecture. Conceptually, collateral flow is insufficient to compensate for the occlusion of a penetrating arteriole because penetrating venules act as shunts of blood that flows through collaterals. Future directions that stem from the analysis of the angioarchitecture concern cellular‐level issues, in particular the regulation of blood flow within the subsurface microvascular network, and system‐level issues, in particular the role of penetrating arteriole occlusions in human cognitive impairment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/micc.12195

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 93

Metadata

Authors
Shih, A. Y., Rühlmann, C., Blinder, P., Devor, A., Drew, P. J., Friedman, B., Knutsen, P. M., Lyden, P. D., Matéo, C., Mellander, L., Nishimura, N., Schaffer, C. B., Tsai, P. S., & Kleinfeld, D.
Venue
Microcirculation
Publisher
Wiley
Published
2015-04
Volume
22
Issue
3
Pages
204-218
ISSN
  • 1073-9688 (ISSN-L)
  • 1549-8719
OpenAlex
W2099194780
Cited by
93
References
33
FWCI
4.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust and Fragile Aspects of Cortical Blood Flow in Relation to the Underlying Angioarchitecture. https://app.cochat.ai/papers/10.1111/micc.12195
The paper
Shih, A. Y., Rühlmann, C., Blinder, P., Devor, A., Drew, P. J., Friedman, B., Knutsen, P. M., Lyden, P. D., Matéo, C., Mellander, L., Nishimura, N., Schaffer, C. B., Tsai, P. S., & Kleinfeld, D. (2015). Robust and Fragile Aspects of Cortical Blood Flow in Relation to the Underlying Angioarchitecture. Microcirculation. https://doi.org/10.1111/micc.12195

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.