CoChat

Overnight automated type 1 diabetes control under MD-logic closed-loop system: a randomized crossover trial: MD-logic AP overnight glucose control

Nimri, Revital, Danne, Thomas, Kordonouri, Olga, Atlas, Eran, Bratina, Natasa, Biester, Torban, Avbelj, Magdalena, Miller, Shahar, Muller, Ido, Phillip, Moshe, Battelino, Tadej · 2013 · Pediatric Diabetes
Cited by 62

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Tight glucose control is needed to prevent long-term diabetes complications; this is hindered by the risk of hypoglycemia, especially at night. OBJECTIVE: To assess the safety and efficacy of the closed-loop MD-Logic Artificial Pancreas (MDLAP), controlling nocturnal glucose levels in patients with type 1 diabetes mellitus (T1DM). RESEARCH DESIGN AND METHODS: This was a randomized, multicenter, multinational, crossover trial conducted in Slovenia, Germany, and Israel. Twelve patients with T1DM (age 23.8 ± 15.6 yr; duration of diabetes 13.5 ± 11.9 yr; A1c 8.1 ± 0.8%, mean ± SD) were randomly assigned to participate in two sequential overnight sessions: one using continuous subcutaneous insulin infusion (CSII) and the other, closed-loop insulin delivery by MDLAP. The primary outcome was the number of hypoglycemic events below 63 mg/dL. Endpoints analyses were based on sensor glucose readings. RESULTS: Three events of nocturnal hypoglycemia occurred during CSII and none during the closed-loop control (p = 0.18). The percentage of time spent in the near normal range of 63-140 mg/dL was significantly higher in the overnight closed-loop sessions [76% (54-85)] than during CSII therapy [29% (11-44)] [p = 0.02, median (interquartile range)]. The mean overnight glucose level was reduced by 36 mg/dL with closed-loop insulin delivery (p = 0.02) with a significantly less glucose variability when compared with the CSII nights (p < 0.001). CONCLUSION: The results of this study demonstrate the ability of the MDLAP to safely improve overnight glucose control without increased risk of hypoglycemia in patients with T1DM at three different national, geographic, and clinical centers (ClinicalTrials.gov number, NCT 01238406).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/pedi.12025

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Nimri, R., Danne, T., Kordonouri, O., Atlas, E., Bratina, N., Biester, T., Avbelj, M., Miller, S., Muller, I., Phillip, M., & Battelino, T.
Venue
Pediatric Diabetes
Published
2013-02
Volume
14
Issue
3
Pages
n/a-n/a
ISSN
1399-543X (ISSN-L)
OpenAlex
W2151133026
Cited by
62
References
11
FWCI
9.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.