CoChat

Non-adjunctive flash glucose monitoring system use during summer-camp in children with type 1 diabetes: The free-summer study

Piona, Claudia, Dovc, Klemen, Mutlu, Gül Y., Grad, Klara, Gregorc, Petra, Battelino, Tadej, Bratina, Nataša · 2018 · Pediatric Diabetes
Cited by 34

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

BACKGROUND: A factory-calibrated sensor for intermittently scanned continuous glucose monitoring (isCGM) is accurate and safe in children with type 1 diabetes (T1D). Data on isCGM effectiveness as a replacement for self-monitoring of blood glucose (SMBG) in this population is scarce. OBJECTIVE: The aim of this study was to evaluate the non-adjunctive use of isCGM in children with T1D during 2 weeks in a challenging summer-camp setting. METHODS: In this two-arm, parallel, randomized, outpatient clinical trial we enrolled 46 children (25 females, mean ± SD: age 11.1 ± 2.6 years, glycated hemoglobin (HbA1c) 7.4% ± 0.7%): 26 in the isCGM group were blinded for the SMBG and insulin dosing was isCGM-based, whereas 20 in the control group were blinded for isCGM and performed SMBG-based insulin dosing. The primary outcome of intention-to-treat analysis was between-group difference in the proportion of time within range 3.9 to 10 mmol/L (TIR). RESULTS: There was no significant difference in TIR (3.9-10 mmol/L) between the two groups. In participants with suboptimal metabolic control (HbA1c > 7%) we observed a significant reduction in time spent above 10 mmol/L (P < 0.05) and an improvement in TIR (P = 0.05) in the isCGM group. No severe hypoglycemic events or serious adverse events occurred. Overall mean absolute relative difference (MARD) between isCGM and SMBG was 18.3%, with median absolute relative difference (ARD) of 8%. Consensus error grid analysis demonstrated 82.2% and 95.2% of results in zone A, and zone A + B, respectively. CONCLUSION: The non-adjunctive use of isCGM was as safe and effective as SMBG, and reduced time spent in hyperglycemia in a sub-population of children with T1D with suboptimal glycemic control. TRIAL REGISTRATION: NCT03182842.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/pedi.12729

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

Metadata

Authors
Piona, C., Dovc, K., Mutlu, G. Y., Grad, K., Gregorc, P., Battelino, T., & Bratina, N.
Venue
Pediatric Diabetes
Publisher
Wiley
Published
2018-08-16
Volume
19
Issue
7
Pages
1285-1293
ISSN
1399-543X (ISSN-L)
OpenAlex
W2883104766
Cited by
34
References
19
FWCI
3.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.