Continuous Glucose Monitoring and Type 1 Diabetes Mellitus Control in Child, Adolescent and Young Adult Population – Arguments for Its Use and Effects
Open accessAbstract
Sensors for continuous glucose monitoring (CGM) in intercellular fluid are used as a contemporary method to achieve better control in type 1 diabetes mellitus (DM), which is best shown through lower glycated hemoglobin (HbA1c) levels.The aim of this study was to assess how many of our patients used CGM (parents were solely financing all the cost of the device) and what was the effect of CGM on the control of DM. Data were retrospectively collected from medical records of patients actively treated at the Division of Endocrinology, Diabetology, Pulmonology and Allergology, Department of Pediatrics, Sestre milosrdnice University Hospital Center. The t-test was used for independent samples to compare the mean levels of HbA1c before and after the inclusion of CGM. CGM was used by 81 (32.1%) of our patients with type 1 DM, of which 43 met the inclusion criteria. The mean HbA1c level 6 months before the introduction of CGM was 8.2%±1.9 and after 12 months of CGM use it was 7.4%±1.2, which was a statistically significant improvement (p=0.026). Furthermore, our results demonstrated that the greatest improvement in HbA1c level was recorded in the groups of young adults (18-25 years) and youngest children (<12 years). We confirmed the efficacy of CGM in achieving better control of type 1 DM by significantly improving HbA1c levels in a population of highly motivated patients.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
CGM has been extensively utilized in patients with Type 1 Diabetes, and emerging evidence supports its potential benefits in managing T2D.
“While CGM has been extensively utilized in patients with Type 1 Diabetes [7–9], emerging evidence supports its potential benefits in managing T2D.”
From Sequential use of continuous glucose monitoring, with or without exercise trackers, significantly improves glycemic control in patients with type 2 diabetes (2025) · cites this paper as [8]
The Introduction describes CGM as a validated method for type 1 diabetes, supporting its established use. But it also says clinical use is “still quite modest” and reports use by 20%–30% of children with type 1 diabetes, so “extensively utilized” overstates this source. The T2D clause follows the citation and is not attributed to it. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254 · see citing works
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893 · see citing works
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494 · see citing works
The fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477 · see citing works
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399 · see citing works
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261 · see citing works
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176 · see citing works
Flagged first, then by citations
Research works printed but not linked: 27
- [1]Rodbard D. Continuous glucose monitoring: a review of successes, challenges and opportunities. Diabetes Technol Ther. 2016; 18 Suppl 2: S3– 13. 10.1089/dia.2015.0417 26784127 PMC4717493 · DOI
- [2]Dovč K Bratina N Battelino T. A new horizon for glucose monitoring. Horm Res Paediatr. 2015; 83: 149– 56. 10.1159/000368924 25660230 · DOI
- [3]Pickup JC Freeman SC Sutton J. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self-monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data. BMJ. 2011; 343: d3805. 10.1136/bmj.d3805 21737469 PMC3131116 · DOI · Paper page
- [4]Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Effectiveness of continuous glucose monitoring in a clinical care environment: evidence from the Juvenile Diabetes Research Foundation Continuous Glucose Monitoring (JDRF-CGM) trial. Diabetes Care. 2010; 33(1): 17– 22. 10.2337/dc09-1502 19837791 PMC2797966 · DOI · Paper page
- [5]Sherr JL Tauschmann M Battelino T de Bock M Forlenza G Roman R ISPAD Clinical Practice Consensus Guidelines 2018: Diabetes technologies. Pediatr Diabetes. 2018 October; 19 Suppl 27: 302– 25. 10.1111/pedi.12731 30039513 · DOI · Paper page
- [8]DiMeglio LA Acerini CL Codner E Craig ME Hofer SE Pillay K ISPAD Clinical Practice Consensus Guidelines 2018: Glycemic control targets and glucose monitoring for children, adolescents and young adults with diabetes. Pediatr Diabetes. 2018 October; 19 Suppl 27: 105– 14. 10.1111/pedi.12737 30058221 · DOI · Paper page
- [9]Laffel L. Improved accuracy of continuous glucose monitoring systems in pediatric patients with diabetes mellitus: results from two studies. Diabetes Technol Ther. 2016; 18 Suppl2: S223– 33. 10.1089/dia.2015.0380 26784126 PMC4717517 · DOI
- [11]Ish-Shalom M Wainstein J Raz I Mosenzon O. Improvement in glucose control in difficult-to-control patients with diabetes using a novel flash glucose monitoring device. J Diabetes Sci Technol. 2016; 10(6): 1412– 3. 10.1177/1932296816653412 27277660 PMC5094332 · DOI
- [12]Rachmiel M Landau Z Boaz M Mazor Aronovitch K Loewenthal N Ben-Ami M The use of continuous glucose monitoring systems in pediatric population with type 1 diabetes mellitus in real life setting: the AweSoMe study group experience. Acta Diabetol. 2015; 52: 323– 9. 10.1007/s00592-014-0643-6 25223531 · DOI
- [13]DeSalvo DJ Miller K Hermann J Maahs D Hofer S Clements M Continuous glucose monitoring (CGM) and glycemic control among youth with type 1 diabetes (T1D): international comparison from the T1D exchange (T1DX) and the DPV initiative. Pediatr Diabetes. 2018; 19(7): 1271– 5. 10.1111/pedi.12711 29923262 PMC6175652 · DOI · Paper page
- [14]Koschinsky T Heinemann L. Sensors for glucose monitoring: technical and clinical aspects. Diabetes Metab Res Rev. 2001; 17: 113– 23. 10.1002/dmrr.188 11307176 · DOI
- [17]Hofer SE Raile K Frohlich-Reiterer E Kapellen T Dost A Rosenbauer J Tracking of metabolic control from childhood to young adulthood in type 1 diabetes. J Pediatr. 2014; 165(5): 956– 61.e1. 10.1016/j.jpeds.2014.07.001 25151197 · DOI
- [18]Writing Team for the DCCT/EDIC Research Group. Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic nephropathy: the Epidemiology of Diabetes Interventions and Complications (EDIC) study. JAMA. 2003; 290(16): 2159– 67. 10.1001/jama.290.16.2159 14570951 PMC2622725 · DOI
- [19]Mohsin F Craig ME Cusumano J Chan AKF Hing S Wing Yee Lee J Discordant trends in microvascular complications in adolescents with type 1 diabetes from 1990 to 2002. Diabetes Care. 2005; 28(8): 1974– 80. 10.2337/diacare.28.8.1974 16043741 · DOI
- [21]Carlsen S Skrivarhaug T Thue G Cooper JG Gøransson L Løvaas K Glycemic control and complications in patients with type 1 diabetes – a registry-based longitudinal study of adolescents and young adults. Pediatr Diabetes. 2017; 18(3): 188– 95. 10.1111/pedi.12372 26875589 · DOI
- [22]Deiss D Bolinder J Riveline JP Battelino T Bosi E Tubiana-Rufi N Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care. 2006; 29(12): 2730– 2. 10.2337/dc06-1134 17130215 · DOI · Paper page
- [24]Weinzimer S Xing D Tansey M Fiallo-Scharer R Mauras N Wysocki T Diabetes Research in Children Network study group. Prolonged use of continuous glucose monitors in children with type 1 diabetes on continuous subcutaneous insulin infusion or intensive multiple-daily injection therapy. Pediatr Diabetes. 2009; 10(2): 91– 6. 10.1111/j.1399-5448.2008.00476.x 19175899 · DOI
- [25]Piona C Dovc K Multu GY Grad K Gregorc P Batelino T Non-adjunctive flash glucose monitoring system use during summer-camp in children with type 1 diabetes – the free summer study. Pediatr Diabetes. 2018; 19(7): 10.1111/pedi.12729 30022571 · DOI
- [26]Yates K Dear K Milton AH Ambler G. Continuous glucose monitoring-guided insulin adjustment in children and adolescents on near-physiological insulin regimens. Diabetes Care. 2006; 29(7): 1512– 7. 10.2337/dc05-2315 16801571 · DOI
- [27]Haviland N Walsh J Roberts R Bailey TS. Update on clinical utility of continuous glucose monitoring in type 1 diabetes. Curr Diab Rep. 2016; 16(11): 115. 10.1007/s11892-016-0808-5 27718171 · DOI
- [29]Tsalikian E Fox L Weinzimer S Buckingam B White NH Beck R Feasibility of prolonged continuous glucose monitoring in toddlers with type 1 diabetes. Pediatr Diabetes. 2012; 13(4): 301– 7. 10.1111/j.1399-5448.2011.00837.x 22151826 PMC3665108 · DOI · Paper page
- [30]Chen C Zhao X-L Li Z-H Zhu Z-G Qian S-H Flewitt AJ. Current and emerging technology for continuous glucose monitoring. Sensors (Basel). 2017; 17: 182. 10.3390/s17010182 28106820 PMC5298755 · DOI
- [32]Battelino T Phillip M Bratina N Nimri R Oskarsson P Bolinder J. Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care. 2011; 34(4): 795– 800. 10.2337/dc10-1989 21335621 PMC3064030 · DOI
- [33]Iscoe KE Campbell JE Jamnik V Perkins AB Riddel MC. Efficacy of continuous real-time blood glucose monitoring during and after prolonged high-intensity cycling exercise: spinning with a continuous glucose monitoring system. Diabetes Technol Ther. 2006 December; 8 Suppl 6: 627– 35. 10.1089/dia.2006.8.627 17109594 · DOI
- [34]Riddell M Perkins BA. Exercise and glucose metabolism in persons with diabetes mellitus: perspectives on the role for continuous glucose monitoring. J Diabetes Sci Technol. 2009; 3 Suppl 4: 914– 23. 10.1177/193229680900300439 20144341 PMC2769951 · DOI
- [35]Tylee TS Trence DL. Glycemic variability: looking beyond the A1c. Diabetes Spectr. 2012; 25(3): 149– 53. 10.2337/diaspect.25.3.149 · DOI
- [36]Lachin JM Bebu I Bergenstal RM Pop-Busui R Service J Zinman B DCCT/EDIC Research Group. Association of glycemic variability in type 1 diabetes with progression of microvascular outcomes in the diabetes control and complications trial. Diabetes Care. 2017; 40(6): 777– 83. 10.2337/dc16-2426 28404658 PMC5439414 · DOI
Cited by
Sorted by citations
Lahiri, A., Lim, S. T., Kyu, H., Dan, Y. Y., & Khoo, C. M. (2025) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-025-02035-6 · Cited by 1 · see citing works
- Authors
- Rubelj, K.
- Affiliations
- University Hospital Centre Zagreb (HR)
- Corresponding author
- Rubelj, Karla
- Venue
- Acta Clinica Croatica
- Published
- 2021
- Volume
- 60
- Issue
- 4
- Pages
- 609-616
- ISSN
- 0353-9466 (ISSN-L)
- PMC
- PMC9196217
- OpenAlex
- W4285547261
- Cited by
- 13
- References
- 8
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 3 · 2023: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Acta Clinica Croatica (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- continuous glucose monitoring, type 1 diabetes, glycemic control, HbA1c, children, adolescents, young adults, pediatric diabetes
- MeSH terms
- Adolescent, Blood Glucose, Child, Diabetes Mellitus, Type 1, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Retrospective Studies, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review