Non-adjunctive flash glucose monitoring system use during summer-camp in children with type 1 diabetes: The free-summer study
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A factory-calibrated sensor for intermittently scanned continuous glucose monitoring (isCGM) is accurate and safe in children with type 1 diabetes (T1D). Data on isCGM effectiveness as a replacement for self-monitoring of blood glucose (SMBG) in this population is scarce. OBJECTIVE: The aim of this study was to evaluate the non-adjunctive use of isCGM in children with T1D during 2 weeks in a challenging summer-camp setting. METHODS: In this two-arm, parallel, randomized, outpatient clinical trial we enrolled 46 children (25 females, mean ± SD: age 11.1 ± 2.6 years, glycated hemoglobin (HbA1c) 7.4% ± 0.7%): 26 in the isCGM group were blinded for the SMBG and insulin dosing was isCGM-based, whereas 20 in the control group were blinded for isCGM and performed SMBG-based insulin dosing. The primary outcome of intention-to-treat analysis was between-group difference in the proportion of time within range 3.9 to 10 mmol/L (TIR). RESULTS: There was no significant difference in TIR (3.9-10 mmol/L) between the two groups. In participants with suboptimal metabolic control (HbA1c > 7%) we observed a significant reduction in time spent above 10 mmol/L (P < 0.05) and an improvement in TIR (P = 0.05) in the isCGM group. No severe hypoglycemic events or serious adverse events occurred. Overall mean absolute relative difference (MARD) between isCGM and SMBG was 18.3%, with median absolute relative difference (ARD) of 8%. Consensus error grid analysis demonstrated 82.2% and 95.2% of results in zone A, and zone A + B, respectively. CONCLUSION: The non-adjunctive use of isCGM was as safe and effective as SMBG, and reduced time spent in hyperglycemia in a sub-population of children with T1D with suboptimal glycemic control. TRIAL REGISTRATION: NCT03182842.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationContinuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · cited 2×
“Comparable improvements in glycemic profile were demonstrated in a large randomized controlled trial comparing the use of rtCGM in pediatric patients with T1D and with HbA1c above 7% treated with insulin pump therapy.18 Results from previous trials and a post hoc analysis of frequent rtCGM users involved in the Juveni…”
ResultMiller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Glycemic Control and Excess Mortality in Type 1 Diabetes
Lind, M., Svensson, A.-M., Kosiborod, M., Gudbjörnsdottir, S., Pivodic, A., Wedel, H., Dahlqvist, S., Clements, M., & Rosengren, A. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1408214 · Cited by 964
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685 · cited 1×
“2% of results in zones A + B is slightly lower compared to data reported previously in larger population of pediatric(26,28,29) and adults patients.(45) The percentage of results with no effect on clinical action according CEG analysis was comparable to that early reported in children (82.”
ResultContinuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M. J., Pillay, K., de Beaufort, C., Craig, M. E., Hanas, R., Acerini, C. L., & Maahs, D. M. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12190 · Cited by 316
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Intensive glucose control versus conventional glucose control for type 1 diabetes mellitus
Fullerton, B., Jeitler, K., Seitz, M., Horvath, K., Berghold, A., & Siebenhofer, A. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009122.pub2 · Cited by 299
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Outcome measures for artificial pancreas clinical trials: a consensus report
Maahs, D. M., Buckingham, B. A., Castle, J. R., Cinar, A., Damiano, E. R., Dassau, E., DeVries, J. H., Doyle, F. J., Griffen, S. C., Haidar, A., et al. (2016) · Diabetes Care · doi:10.2337/dc15-2716 · Cited by 211 · cited 1×
“The impossibility of masked the intervention is recognized as common limitation in glucose technology studies.(49) Furthermore, other limitations were due to the inclusion and the exclusion criteria: all the participants were treated with continuous subcutaneous insulin infusion (CSII) and patients with significant hy…”
BackgroundMauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204
Ólafsdóttir, A. F., Attvall, S., Sandgren, U., Dahlqvist, S., Pivodic, A., Skrtic, S., Theodorsson, E., & Lind, M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0392 · Cited by 173
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Freckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
Cowart, K., Updike, W., & Bullers, K. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0345 · Cited by 36
Rubelj, K. (2021) · Acta Clinica Croatica · doi:10.20471/acc.2021.60.04.07 · Cited by 13
Metadata
- Authors
- Piona, C., Dovc, K., Mutlu, G. Y., Grad, K., Gregorc, P., Battelino, T., & Bratina, N.
- Venue
- Pediatric Diabetes
- Publisher
- Wiley
- Published
- 2018-08-16
- Volume
- 19
- Issue
- 7
- Pages
- 1285-1293
- ISSN
- 1399-543X (ISSN-L)
- OpenAlex
- W2883104766
- Cited by
- 34
- References
- 19
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.