Toward a better noninvasive assessment of preejection period: A novel automatic algorithm for B‐point detection and correction on thoracic impedance cardiogram
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Impedance cardiography is the most common clinically validated, noninvasive method for determining the timing of the opening of the aortic valve, an important event used for measuring preejection period, which reflects sympathetic beta‐adrenergic influences on the heart. Automatic detection of the exact time of the opening of the aortic valve (B point on the impedance cardiogram) has proven to be challenging as its appearance varies between and within individuals and may manifest as a reversal, inflection, or rapid slope change of the thoracic impedance derivative's (dZ/dt) rapid rise. Here, a novel automatic algorithm is proposed for the detection of the B point by finding the main rapid rise of the dZ/dt signal, which is due to blood ejection. Several conditions based on zero crossings, minima, and maxima of the dZ/dt signal and its derivatives are considered to reject any unwanted noise and artifacts and select the true B‐point location. The detected B‐point locations are then corrected by modeling the B‐point time data using forward and reverse autoregressive models. The proposed algorithm is validated against expert‐detected B points and is compared with different conventional methods; it significantly outperforms them by at least 54% in mean error, 30% in mean absolute error, and 27% in standard deviation of error. This algorithm can be adopted in ambulatory studies requiring beat‐to‐beat evaluation of cardiac hemodynamic parameters over extended time periods where expert scoring is not feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A critical review of the systolic time intervals.
Lewis, R. P., Rittogers, S. E., Froester, W. F., & Boudoulas, H. (1977) · Circulation · doi:10.1161/01.cir.56.2.146 · Cited by 624
Autonomic activity during human sleep as a function of time and sleep stage
Trinder, J., Kleiman, J., Carrington, M., Smith, S., Breen, S., Tan, N., & Kim, Y. (2001) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2001.00263.x · Cited by 507
Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the Heart
Newlin, D. B., & Levenson, R. W. (1979) · Psychophysiology · doi:10.1111/j.1469-8986.1979.tb01519.x · Cited by 275 · cited 1×
“…in mind that there are other issues with the interpretation of PEP, regardless of accuracy of measurement, such as the influence of the afterload on PEP independent of beta-adrenergic control (Newlin & Levenson, 1979), which needs to be corrected (Trinder, et al., 2001) in psychophysiology studies.”
Background
Cited by
Dynamic coupling between the central and autonomic nervous systems during sleep: a review
de Zambotti, M., Trinder, J., Silvani, A., Colrain, I. M., & Baker, F. C. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.03.027 · Cited by 194
Self-citationBahrami, M., & Forouzanfar, M. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3151947 · Cited by 173
Self-citationContext-aware experience sampling reveals the scale of variation in affective experience
Hoemann, K., Khan, Z., Feldman, M. J., Nielson, C., Devlin, M., Dy, J., Barrett, L. F., Wormwood, J. B., & Quigley, K. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69180-y · Cited by 124
Hoemann, K., Khan, Z., Kamona, N., Dy, J., Barrett, L. F., & Quigley, K. S. (2021) · Psychophysiology · doi:10.1111/psyp.13818 · Cited by 40
“Physiological signals were processed as follows, using an in- house pipeline coded in Python (Forouzanfar et al., 2018; Nabian et al., 2018; see also Hoemann et al., 2020).”
Method
Metadata
- Authors
- Forouzanfar, M., Baker, F. C., de Zambotti, M., McCall, C., Giovangrandi, L., & Kovacs, G. T. A.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2018-03-07
- Volume
- 55
- Issue
- 8
- Pages
- e13072-e13072
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2791160102
- Cited by
- 45
- References
- 3
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward a better noninvasive assessment of preejection period: A novel automatic algorithm for B‐point detection and correction on thoracic impedance cardiogram. https://app.cochat.ai/papers/10.1111/psyp.13072
- The paper
- Forouzanfar, M., Baker, F. C., de Zambotti, M., McCall, C., Giovangrandi, L., & Kovacs, G. T. A. (2018). Toward a better noninvasive assessment of preejection period: A novel automatic algorithm for B‐point detection and correction on thoracic impedance cardiogram. Psychophysiology. https://doi.org/10.1111/psyp.13072
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.