The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Capillary filtration‐absorption balance reconsidered in light of dynamic extravascular factors
Abstract
The evidence for the functional importance of extravascular Starling pressures now seems overwhelming, and when these terms are taken into account it is difficult to uphold the traditional conception that upstream microvascular filtration is largely matched by a sustained downstream reabsorption. Transient absorption can occur, however, during spontaneous vasomotion cycles, during sympathetic‐induced vasoconstriction and during hypovolaemic hypotension. Sustained absorption is possible in specialized tissues where the interstitium is ‘flushed’ by an independent stream (intestinal mucosa, renal cortex, lymph nodes). Both theory and experiment show, however, that absorption cannot be maintained across most low‐pressure exchange segments due to the finite permeability of microvessels to plasma protein, which leads to a rise in pericapillary interstitial oncotic pressure with time around absorbing microvascular segments. Extravascular hydraulic resistance may be a further determinant of net fluid transfer rate in situations where capillary wall resistance is low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some consequences of capillary permeability to macromolecules: Starling's hypothesis reconsidered
Renkin, E. M. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.250.5.h706 · Cited by 148 · cited 1×
“& HERMANSEN, L. (1984). Intramuscular fluid pressure during isometric contraction of human skeletal muscle.”
Background
Cited by
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
Vascular Endothelial Cell Biology: An Update
Krüger-Genge, A., Blocki, A., Franke, R.-P., & Jung, F. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20184411 · Cited by 1,163
The endothelial glycocalyx: a review of the vascular barrier
Alphonsus, C. S., & Rodseth, R. N. (2014) · Anaesthesia · doi:10.1111/anae.12661 · Cited by 460
Body Fluid Dynamics: Back to the Future
Bhave, G., & Neilson, E. G. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2011080865 · Cited by 215
Scallan, J. P., & Huxley, V. H. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2009.179622 · Cited by 84
Metadata
- Authors
- Levick
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 1991-11
- Volume
- 76
- Issue
- 6
- Pages
- 825-857
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W2079338335
- Cited by
- 190
- References
- 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary filtration‐absorption balance reconsidered in light of dynamic extravascular factors. https://app.cochat.ai/papers/10.1113/expphysiol.1991.sp003549
- The paper
- Levick. (1991). Capillary filtration‐absorption balance reconsidered in light of dynamic extravascular factors. Experimental Physiology. https://doi.org/10.1113/expphysiol.1991.sp003549
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.