Capillary filtration‐absorption balance reconsidered in light of dynamic extravascular factors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The evidence for the functional importance of extravascular Starling pressures now seems overwhelming, and when these terms are taken into account it is difficult to uphold the traditional conception that upstream microvascular filtration is largely matched by a sustained downstream reabsorption. Transient absorption can occur, however, during spontaneous vasomotion cycles, during sympathetic‐induced vasoconstriction and during hypovolaemic hypotension. Sustained absorption is possible in specialized tissues where the interstitium is ‘flushed’ by an independent stream (intestinal mucosa, renal cortex, lymph nodes). Both theory and experiment show, however, that absorption cannot be maintained across most low‐pressure exchange segments due to the finite permeability of microvessels to plasma protein, which leads to a rise in pericapillary interstitial oncotic pressure with time around absorbing microvascular segments. Extravascular hydraulic resistance may be a further determinant of net fluid transfer rate in situations where capillary wall resistance is low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Some consequences of capillary permeability to macromolecules: Starling's hypothesis reconsidered
Renkin, E. M. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.250.5.h706 · Cited by 148 · cited 1×
“& HERMANSEN, L. (1984). Intramuscular fluid pressure during isometric contraction of human skeletal muscle.”
Background
Cited by
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Microvascular fluid exchange and the revised Starling principle
Levick, J. R., & Michel, C. C. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq062 · Cited by 1,183
“It is important to note that since the Starling pressures differ between tissues and species, a correct sum of forces necessitates measurement of all four forces in the same tissue.(19) The absence of a net absorptive”
BackgroundVascular Endothelial Cell Biology: An Update
Krüger-Genge, A., Blocki, A., Franke, R.-P., & Jung, F. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20184411 · Cited by 1,163
Michel, C. C., & Curry, F. E. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.3.703 · Cited by 811
Rasmussen, M. K., Mestre, H., & Nedergaard, M. (2022) · Physiological Reviews · doi:10.1152/physrev.00031.2020 · Cited by 597
The endothelial glycocalyx: a review of the vascular barrier
Alphonsus, C. S., & Rodseth, R. N. (2014) · Anaesthesia · doi:10.1111/anae.12661 · Cited by 460
Oncotic pressures opposing filtration across non‐fenestrated rat microvessels
Adamson, R. H., Lenz, J. F., Zhang, X., Adamson, G. N., Weinbaum, S., & Curry, F. E. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.058255 · Cited by 323
Endothelial glycocalyx and coronary vascular permeability: the fringe benefit
Becker, B. F., Chappell, D., & Jacob, M. (2010) · Basic Research in Cardiology · doi:10.1007/s00395-010-0118-z · Cited by 277
Capillary Fluid Exchange: Regulation, Functions, and Pathology
Scallan, J., Huxley, V. H., & Korthuis, R. J. (2010) · Colloquium Series on Integrated Systems Physiology: From Molecule to Function · doi:10.4199/c00006ed1v01y201002isp003 · Cited by 256
Body Fluid Dynamics: Back to the Future
Bhave, G., & Neilson, E. G. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2011080865 · Cited by 215
JACOB, M., BRUEGGER, D., REHM, M., STOECKELHUBER, M., WELSCH, U., CONZEN, P., & BECKER, B. (2007) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.11.021 · Cited by 180
“The latter property is in accordance with the newly realised fact that, in contrast to Starling's concept, there is no net reabsorption of fluid in the venular segments of the microcirculation [1,3].”
BackgroundResultA New View of Starling's Hypothesis at the Microstructural Level
Hu, X., & Weinbaum, S. (1999) · Microvascular Research · doi:10.1006/mvre.1999.2177 · Cited by 163
Scallan, J. P., & Huxley, V. H. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2009.179622 · Cited by 84
“…experimental studies have provided evidence that filtration occurs throughout the microvascular network of vessels, with reabsorption only occurring during special states (e.g. increased tissue hydrostatic pressure) or in encapsulated organs (Renkin, 1986; Michel & Phillips, 1987; Levick, 1991).”
BackgroundLocal Regulation of Microvascular Perfusion
Davis, M. J., Hill, M. A., & Kuo, L. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00006-1 · Cited by 78
Metadata
- Authors
- Levick
- Venue
- Experimental Physiology
- Publisher
- Wiley
- Published
- 1991-11
- Volume
- 76
- Issue
- 6
- Pages
- 825-857
- ISSN
- 0958-0670 (ISSN-L)
- 1469-445X
- OpenAlex
- W2079338335
- Cited by
- 190
- References
- 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.