The effects of load and force on tremor at the normal human elbow joint
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
1. Spontaneous flexion‐extension tremor of the elbow was recorded in normal human subjects while they exerted a flexing force against different loads. 2. Increases in the flexing force up to ½ or ¾ of the subject's maximum were accompanied by increases in the amplitude of the tremor. A further increase to very large forces was associated with a decrease in tremor. 3. When the subject flexed against a spring, the frequency of the tremor was related to the properties of the spring; with increasingly stiff springs the tremor frequency increased up to about 12 Hz. With the stiffest springs, however, the tremor became irregular and very small in amplitude. 4. Weights added to the limb at the wrist reduced the frequency of tremor. 5. By using appropriate combinations of spring and mass, the principal tremor frequency could be adjusted between 2 and 12 Hz, higher in some subjects. Within this range the frequency 2 was approximately proportional to the spring stiffness/mass, just as it is in a spring‐mass system, though the forearm provided some of this mass, and some of the spring‐like resistance was in the flexor muscles. 6. When by suitable loading the tremor frequency was brought between 8 and 12 Hz, and the subject forcibly flexed his elbow, the tremor became regular and large in amplitude. This was a form of limited instability in the stretch reflex which arose because a powerful reflex response to extension of the elbow acted back on the flexor muscles after a delay. 7. When the limb was so loaded that its natural frequency was outside this 8–12 Hz range, it behaved as a filter, and in response to any disturbing noise it oscillated mainly at frequencies close to the natural frequencies of either the mechanical system or the stretch reflex. 8. This filtering function of the limb with its stretch reflex probably plays an important part in the control of normal movement and tremor. 9. The large flexing forces that were here associated with vigorous tremor normally occur when a limb supports a large mass. Such a mass would give the mechanical system within the limb a low natural frequency; inconveniently large oscillations in the 8–12 Hz range would therefore seldom occur.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The low weight of these IMUs, around 40 g, makes them an optimal solution for our application, as tremor would change its characteristics if a larger mass were attached to the limbs [7].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [7]
In the citing paper
“It is based on the fact that most types of tremors change their characteristics (amplitude and frequency) when the apparent limb impedance is modified, for example, applying a force or adding a mass [6–8].”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [7]
In the citing paper
“However, it has been shown by several researchers that loading of the tremorous body part (externally or internally) can cause changes to the tremor properties, such as the amplitude and frequency (Joyce and Rack, 1974; Rack and Ross, 1986; Aisen et al., 1993; Héroux et al., 2009).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Joyce and Rack, 1974
Citations
Cites
Observations on the control of stepping and hopping movements in man
Jones, G. M., & Watt, D. G. D. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009684 · Cited by 577
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
NERVOUS GRADATION OF MUSCULAR CONTRACTION
HAMMOND, P. H., MERTON, P. A., & SUTTON, G. G. (1956) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a069553 · Cited by 224
Mechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
An analysis of the frequencies of finger tremor in healthy subjects
Halliday, A. M., & Redfearn, J. W. T. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005668 · Cited by 175
Joyce, G. C., Rack, P. M. H., & Ross, H. F. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010614 · Cited by 153
Self-citationMarshall, J., & Walsh, E. G. (1956) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.19.4.260 · Cited by 131
Relationship between forearm tremor and the biceps electromyogram
Fox, J. R., & Randall, J. E. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.29.1.103 · Cited by 95
The significance of grouping of motor unit activity
Taylor, A. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006930 · Cited by 88
The variation of hand tremor with force in healthy subjects
Sutton, G. G., & Sykes, K. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008276 · Cited by 70
Cited by
Items 101–166 of 166
Durbaba, R., Cassidy, A., Budini, F., & Macaluso, A. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00917.2011 · Cited by 17
“This induced tremor during anisometric contractions has been attributed to the stretch reflex pathway (21, 24, 43, 50, 55, 78, 79, 88).”
BackgroundInfluentialHwang, I., Chen, Y.-C., & Wu, P.-S. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-0981-1 · Cited by 18
“However, load superimposition does not always produce tremor potentiation (Joyce and Rack 1974).”
BackgroundAssessing muscular fatigue with a portable tremor measurement system suitable for field use
Galinsky, T. L., Rosa, R. R., & Wheeler, D. D. (1990) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03204434 · Cited by 16
Tuning the power spectrum of physiological finger tremor frequency with flickering light
Isokawa-Akesson, M., & Komisaruk, B. R. (1985) · Journal of Neuroscience Research · doi:10.1002/jnr.490140309 · Cited by 15
Human servo responses to load disturbances in fatigued muscle
Darling, W. G., & Hayes, K. C. (1983) · Brain Research · doi:10.1016/0006-8993(83)90887-9 · Cited by 18
Effects of strength training-induced fatigue on tremor spectrum in elbow flexion
Viitasalo, J. T., & Gajewski, J. (1994) · Human Movement Science · doi:10.1016/0167-9457(94)90032-9 · Cited by 14
Tremor Suppression With Mechanical Vibration Stimulation
Liu, W., Kai, T., & Kiguchi, K. (2020) · IEEE Access · doi:10.1109/access.2020.3045023 · Cited by 13
A numeric study of the noise-induced tremor in a mathematical model of the stretch reflex
Santillán, M., Hernández-Pérez, R., & Delgado‐Lezama, R. (2003) · Journal of Theoretical Biology · doi:10.1016/s0022-5193(03)00016-x · Cited by 13
Pickett, C. W., Nosaka, K., Zois, J., & Blazevich, A. J. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003235 · Cited by 11
“This tremor may be generated by muscle and tendon length changes during maximal voluntary contractions initiating Ia afferent activation as part of a negative feedback loop (24,26,27).”
BackgroundStudies on Muscle Spindle Primary Endings with Sinusoidal Stretching
Goodwin, G. M., Hulliger, M., & Matthews, P. B. C. (1976) · Progress in brain research · doi:10.1016/s0079-6123(08)60725-6 · Cited by 11
Periodontal mechanoreceptors and bruxism at low bite forces
Yılmaz, G., Laine, C. M., Tınastepe, N., Özyurt, M. G., & Türker, K. S. (2018) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2018.11.011 · Cited by 10
Segmental reflex, muscle mechanical and central mechanisms underlying human physiological tremor
Allum, J. H. J. (1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2_8 · Cited by 14
Nagasaki, H., & Nakamura, R. (1985) · Perceptual and Motor Skills · doi:10.2466/pms.1985.61.3.847 · Cited by 9
Mandibular tremor during isometric contractions
Sowman, P. F., & Türker, K. S. (2006) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2006.09.006 · Cited by 9
Budini, F., Močnik, R., Tilp, M., & Crognale, D. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-05039-6 · Cited by 8
“The possibility of an entrainment between physiological tremor and voice-induced vibration is, however, unlikely because, first, specific mechanical oscillation frequencies are required for that to happen (Halliday and Redfearn 1956; Lippold 1970; Joyce and Rack 1974), and second, while tremor frequency is very simila…”
BackgroundInfluentialAlbertsen, I. M., Temprado, J.-J., Berton, É., & Heuer, H. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.03.005 · Cited by 7
“…De Luca, 1993; Collins et al., 1995), these findings indicate decreased steady-state muscle activity in the presence of haptic cues and, thus, reduced noise-like fluctuations in the motor output (Joyce and Rack, 1974; see Jeka and Lackner, 1995 for a consistent interpretation using EMG analysis).”
BackgroundThree-dimensional assessment of postural tremor during goal-directed aiming
Kelleran, K. J., Morrison, S., & Russell, D. M. (2016) · Experimental Brain Research · doi:10.1007/s00221-016-4738-x · Cited by 8
“For example, the resonant frequency properties of the finger, hand and forearm segments have been reported at 20–25, 8–12 and 2–4 Hz, respectively (Joyce and Rack 1974; Elble and Randall 1978; Homberg et al. 1987; Elble and Koller 1990; Hwang et al. 2009).”
BackgroundMurnaghan, C. D., Carpenter, M. G., Chua, R., & Inglis, J. T. (2016) · Journal of Neurophysiology · doi:10.1152/jn.01150.2015 · Cited by 11
“…the small, involuntary displacements of the limb that occur during attempts to maintain a static position against a load (Chew et al. 2008; Joyce and Rack 1974) and observed larger low frequency components that become more dominant following changes in the mechanical properties of the…”
BackgroundInfluentialPathak, A. (2010) · Deep Blue (University of Michigan) · Cited by 10
In-Situ Force Augmentation Improves Surface Contact and Force Control
Lee, R., Klatzky, R. L., & Stetten, G. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2696949 · Cited by 6
“Effects of tremor under light load and while holding a tool are not well studied, although higher loads at different joints produce complex relationships with tremor [30], [31], [32].”
The effects of cold on a partially denervated muscle.
Rack, P. M. H., & Fox, J. E. (1987) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.50.4.460 · Cited by 6
Self-citationDynamic properties of human goal-directed arm movements
Bock, O. L. (1990) · Behavioural Brain Research · doi:10.1016/0166-4328(90)90030-i · Cited by 7
Johnson, S. W., Lynn, P. A., Reed, G. A. L., & Miller, J. S. G. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442715 · Cited by 7
Essential tremor: treatment with beta-adrenoceptor blocking drugs
Wilson, J. F., Marshall, R. W., & Richens, A. (1984) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06757-2_17 · Cited by 8
Effect of a Wrist Harmonic Liquid Tremor Absorber‐Damping on the Upper Extremity Essential Tremor
Tarlacı, S., & Doğan, F. (2025) · Movement Disorders · doi:10.1002/mds.30102 · Cited by 5
Mandibular postural tremor during relaxation and during volitional innervation of the jaw muscles
de Vries, J. H., Schoo, W. H., Macken, G. G. M., & van Steenberghe, D. (1984) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00584834 · Cited by 6
“Stretch reflex activity was found to contribute to tremor at the human elbow (Joyce and Rack 1974) and the thumb (Brown et al.”
BackgroundMonitoring Accumulative Fatigue of Finger by Autoregressive Modeling of Physiological Tremor.
Miao, T., & Sakamoto, K. (1995) · Applied Human Science Journal of Physiological Anthropology · doi:10.2114/ahs.14.29 · Cited by 5
Allum, J. H. J., & Hulliger, M. (1982) · Neuroscience Letters · doi:10.1016/0304-3940(82)90076-3 · Cited by 4
A capacitance-gauge force transducer for isolated muscle fibres [proceedings].
Cecchi, G., Colomo, F., & Lombardi (1979) · PubMed Central · Cited by 4
A method for studying the cyclic changes in nasal resistance in the anaesthetized pig [proceedings].
Eccles, R. M. (1978) · PubMed Central · Cited by 3
A computer program for linear nonparametric and parametric identification of biological data
Werness, S. A. S., & Anderson, D. J. (1984) · Computer Programs in Biomedicine · doi:10.1016/0010-468x(84)90025-4 · Cited by 3
An intrinsic mechanism for the oscillatory contraction of muscle
Akamatsu, N., Hannaford, B., & STARK, L. W. (1988) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1988.94956 · Cited by 2
Modulation of Human Spinal Reflexes
Gottlieb, G. L., & Agarwal, G. C. (1984) · Elsevier eBooks · doi:10.1016/b978-0-12-079040-1.50006-5 · Cited by 2
Principios biomecánicos para la supresión del temblor por medios ortésicos.
LOIS, J. M. B. (2009) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/4702 · Cited by 2
“La resonancia mecánica, por sí misma no produciría temblor o en todo caso produciría una oscilación subamortiguada [43, 71], para que exista temblor se necesita de algún ruido o fuente de excitación que la mantenga.”
BackgroundWindhorst, U., & Koehler, W. (1982) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00582938 · Cited by 2
Budini, F., Močnik, R., Tilp, M., & Crognale, D. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e33459 · Cited by 2
“…be suggested that the sound produced by the responses induced a rhythmical oscillation that could have entrained with the natural oscillation of the investigated limb, in a similar way mechanical oscillations can entrain with servo feedback loops, resulting in an increase of tremor [15 – 20].”
BackgroundGABAergic neuronal dysfunction underlies tremor in spinocerebellar ataxia 3
Banerjee, A., Chatterjee, M., Tan, K. J., Tay, S. H., Duan, K., Andiappan, A. K., Howland, S. W., Aso, Y., & Aw, S. (2025) · Disease Models & Mechanisms · doi:10.1242/dmm.052329 · Cited by 1
“Yet others have posited a biophysical underpinning based on natural mechanical resonant frequencies of the extremities (Joyce and Rack, 1974).”
ELECTROMYOGRAPHY AND DISORDERS OF THE CENTRAL NERVOUS SYSTEM
Brown, W. F. (1984) · Elsevier eBooks · doi:10.1016/b978-0-409-95042-7.50017-7 · Cited by 1
Knee angle as a determinant of lower leg tremor
Viitasalo, J. T., & Gajewski, J. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90023-x · Cited by 1
Load-induced changes in older individual's hand-finger tremor are ameliorated with targeting
Kavanagh, J. J., Cross, T. J., Newell, K. M., & Morrison, S. (2014) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2014.01.023 · Cited by 1
“Some of the more common task demands that have been employed to assess tremor properties include altering the inertial properties of a segment with loading [3,4], performing the task with more than one segment [5,6] and/or manipulating the availability of visual feedback during the tremor task [7,8].”
MethodThe effect of arginine vasopressin (AVP) on the distribution of fluid in the rat [proceedings].
Floyer, M. A., & Dv, M. (1976) · PubMed · Cited by 3
Phomsoupha, M., Jeuvrey, J., & Laffaye, G. (2020) · Human Sport Medicine · doi:10.14529/hsm200212 · Cited by 1
A microprocessor-based ultrasonic limb movement monitoring system
Brown, A. W. S. (1981) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(81)90131-x · Cited by 1
Characteristics of Upper Limb Tremor in Healthy Adult Women in Different Age Groups
Yamaji, T., & Sakamoto, K. (2006) · Rigakuryoho Kagaku · doi:10.1589/rika.21.49 · Cited by 1
Exploring the nature of postural sway
Murnaghan, C. D. (2013) · cIRcle (University of British Columbia) · doi:10.14288/1.0073647 · Cited by 1
“…1969), the firing pattern of motor units (Allum, Dietz, & Freund, 1978), the tendency for a mechanical system to oscillate at a natural frequency (Joyce & Rack, 1974), the timing of stretch reflexes (A. M. Halliday & Redfearn, 1958; Joyce & Rack, 1974), as well as a central oscillator contained…”
BackgroundThe effects of the motion mode on surface electromyograms during dynamic contractions.
OHASHI, J., & Iwanaga, K. (1985) · The Annals of physiological anthropology · doi:10.2114/ahs1983.4.17 · Cited by 1
Albano, J. D. M., Kd, B., & Rf, H. (1978) · PubMed Central · Cited by 1
Wray, D. (1978) · PubMed Central · Cited by 1
A critique of the papers by Houk, Crago and Rymer; Hoffer and Andreassen; Allum; and Dietz
Rack, P. M. H. (1981) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06022-1_37 · Cited by 2
Self-citationThe quantification of the online control of goal-directed movement using frequency domain analysis
de Grosbois, J. P., & Paul, J. (2017) · TSpace (University of Toronto) · Cited by 1
Oguztöreli, M. N., & Stein, R. B. (1977) · Elsevier eBooks · doi:10.1016/b978-0-12-434150-0.50026-6 · Cited by 2
A Dynamical Approach to Normal and Parkinsonian Tremor
Beuter, A. C., & de Geoffroy, A. (1995) · Springer series in synergetics · doi:10.1007/978-3-642-79290-8_12
Daneault, J. (2009) · Archipel (Université du Québec à Montréal)
Design of a haptic environment to study the effect of loading on resting and action tremors
Sajith, K., & Chaudhuri, S. (2013) · International Conference on Ubiquitous Robots and Ambient Intelligence · doi:10.1109/urai.2013.6677312
“Authors in [7] analyzed the results of adding force and inertia on physiological tremor, that in [8] analyzed the variation in pathological tremor properties due to inertial and force loading.”
BackgroundKnee angle as a determinant of lower leg tremor
Viitasalo, J. T., & Gajewski, J. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90601-a
Effects of muscle torque and stiffness of spring load on human lower leg tremor
Gajewski, J., & Viitasalo, J. T. (1993) · Human Movement Science · doi:10.1016/0167-9457(93)90018-k
Sakamoto, K., Kurokawa, T., Yamaji, T., Mito, K., & Takanokura, M. (2008) · The Japanese Journal of Ergonomics · doi:10.5100/jje.44.151
Automatic switching unit for iontophoresis panels [proceeding].
Cj, C. (1977) · PubMed Central
Johnson, S. W., Lynn, P. A., Miller, S., & Reed, G. A. L. (1981) · Palgrave Macmillan UK eBooks · doi:10.1007/978-1-349-06022-1_40 · Cited by 2
Lau, K., Fok, K. L., Lee, J., & Masani, K. (2026) · PLoS ONE · doi:10.1371/journal.pone.0338581
“Their methodological differences, along with the limitations of the current sample (i.e., healthy young males), warrant further research to evaluate their comparability across different populations and contexts [39,40,41,42,43,44,45,46,47].”
The role of neurorehabilitation in the suppression of pathological tremor
Lora-Millán, J. S., & Rocón, E. (2025) · Elsevier eBooks · doi:10.1016/b978-0-12-819877-3.00011-1 · Cited by 1
Stein, R. B., & Lee, R. G. (1981) · Comprehensive physiology · doi:10.1002/j.2040-4603.1981.tb00847.x · Cited by 21
“Joyce and Rack (66) were able to produce substantial Frequencies near this upper limit are found in rather rhythmic oscillations at frequencies from 2 to more skilled movements such as handwriting, and it has than 20 Hz.”
InfluentialAlbertsen, I. M. (2012) · theses.fr (ABES) · doi:10.70675/0560d353za7afz4ef8z86a3z073ce7afda2d
Déterminants biomécanique, physiologique et modélisation physique de la performance en badminton
Phomsoupha, M. (2016) · theses.fr (ABES) · doi:10.70675/9b80f06cz3badz4ae7zac8dzeeec0812181d
Characteristics of accelerometric activity of the head in healthy subjects at rest and in postures
Kovács, A., Hejczei, L., Váraljai, C., Abrantes, M., Györfi, O., & Kamondi, A. (2026) · Clinical Neurophysiology · doi:10.1016/j.clinph.2026.2112429 · Cited by 1
Harris, D. J., & Parmentier, J. (1985) · Springer eBooks · doi:10.1007/978-3-642-70618-9_7
Metadata
- Authors
- Joyce, G. C., & Rack, P. M. H.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1974-07
- Volume
- 240
- Issue
- 2
- Pages
- 375-396
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1331021
- OpenAlex
- W1989458918
- Cited by
- 167
- References
- 15
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2022: 2 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 2 · 2016: 6 · 2015: 1 · 2014: 6 · 2013: 4 · 2012: 1
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- tremor frequency, tremor amplitude, mass-spring system, natural frequencies, stretch reflex, flexor muscles, tremor filtering, motor control
- MeSH terms
- Adolescent, Adult, Biomechanical Phenomena, Child, Elbow, Physical Exertion, Female, Forearm, Humans, Male, Middle Aged, Muscles, Reflex, Wrist
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.