The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
The relation between the surface electromyogram and muscular force.
Open accessAbstract
1. Motor units in the first dorsal interosseus muscle of normal human subjects were recorded by needle electrodes, together with the surface electromyogram (e.m.g.). The wave form contributed by each motor unit to the surface e.m.g. was determined by signal averaging. 2. The peak‐to‐peak amplitude of the wave form contributed to the surface e.m.g. by a motor unit increased approximately as the square root of the threshold force at which the unit was recruited. The peak‐to‐peak duration of the wave form was independent of the threshold force. 3. Large and small motor units are uniformly distributed throughout this muscle, and the muscle fibres making up a motor unit may be widely dispersed. 4. The rectified surface e.m.g. was computed as a function of force, based on the sample of motor units recorded. The largest contribution of motor unit recruitment occurs at low force levels, while the contribution of increased firing rate becomes more important at higher force levels. 5. Possible bases for the common experimental observation that the mean rectified surface e.m.g. varies linearly with the force generated by a muscle are discussed. E.m.g. potentials and contractile responses may both sum non‐linearly at moderate to high force levels, but in such a way that the rectified surface e.m.g. is still approximately linearly related to the force produced by the muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathematical Analysis of Random Noise
Rice, S. O. (1944) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1944.tb00874.x · Cited by 5,480
The Theory of Stochastic Processes
Cox, D. R., Miller, H. D., Weiss, G., & Shuler, K. (1966) · Physics Today · doi:10.1063/1.3047872 · Cited by 3,324
The orderly recruitment of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010192 · Cited by 920
Self-citationAdrian, E. D., & Bronk, D. W. (1929) · The Journal of Physiology · doi:10.1113/jphysiol.1929.sp002557 · Cited by 787
The relation between force, velocity and integrated electrical activity in human muscles
Bigland, B., & Lippold, O. C. J. (1954) · The Journal of Physiology · doi:10.1113/jphysiol.1954.sp005044 · Cited by 766
The relation between integrated action potentials in a human muscle and its isometric tension
Lippold, O. C. J. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004763 · Cited by 653
Changes in firing rate of human motor units during linearly changing voluntary contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010193 · Cited by 553
Self-citationThe contractile properties of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010087 · Cited by 476
Self-citationMORPHOLOGIC STUDIES OF MOTOR UNITS IN NORMAL HUMAN MUSCLES
Feinstein, B., Lindegård, B., Nyman, E., & Wohlfart, G. (1955) · Cells Tissues Organs · doi:10.1159/000140989 · Cited by 433
Relation of human electromyogram to muscular tension
Inman, V. T., Ralston, H. J., De C.M. Saunders, J. B., Bertram Feinstein, M. B., & Wright, E. W. (1952) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(52)90008-4 · Cited by 431
Cited by
Changes in muscle contractile properties and neural control during human muscular fatigue
Bigland‐Ritchie, B., & Woods, J. J. (1984) · Muscle & Nerve · doi:10.1002/mus.880070902 · Cited by 1,050
The importance of muscular strength: Training considerations
Suchomel, T. J., Nimphius, S., Bellon, C. R., & Stone, M. H. (2018) · Sports Medicine · doi:10.1007/s40279-018-0862-z · Cited by 940
“The recruitment order may be maintained during slow, graded, isometric [43], and ballistic actions [44, 45].”
BackgroundCormie, P., McGuigan, M. R., & Newton, R. U. (2011) · Sports Medicine · doi:10.2165/11538500-000000000-00000 · Cited by 808
Developing Maximal Neuromuscular Power: Part 1 – Biological Basis of Maximal Power Production
Cormie, P., McGuigan, M. R., & Newton, R. U. (2011) · Sports Medicine · doi:10.2165/11537690-000000000-00000 · Cited by 774
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
Regulation of soleus muscle stiffness in premammillary cats: intrinsic and reflex components.
Hoffer, J. A., & Andreassen, S. (1981) · Journal of Neurophysiology · doi:10.1152/jn.1981.45.2.267 · Cited by 616
Jones, D. A., Bigland-Ritchie, B., & Edwards, R. H. T. (1979) · Experimental Neurology · doi:10.1016/0014-4886(79)90279-6 · Cited by 588
The origin and use of positional frames of reference in motor control
Feldman, A. G., & Levin, M. F. (1995) · Behavioral and Brain Sciences · doi:10.1017/s0140525x0004070x · Cited by 585
Yao, W., Fuglevand, R. J., & Enoka, R. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.441 · Cited by 473
Myoelectric signal versus force relationship in different human muscles
Lawrence, J. H., & De Luca, C. J. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.6.1653 · Cited by 453
Surface Electromyographic Analysis of Exercises for the Trapezius and Serratus Anterior Muscles
Ekstrom, R. A., Donatelli, R. A., & Soderberg, G. L. (2003) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2003.33.5.247 · Cited by 411
Methodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
Bigland-Ritchie, B., Jones, D. A., & Woods, J. J. (1979) · Experimental Neurology · doi:10.1016/0014-4886(79)90280-2 · Cited by 349
Doherty, T. J., & Brown, W. F. (1993) · Muscle & Nerve · doi:10.1002/mus.880160404 · Cited by 316
Integrated electromyogram and oxygen uptake during positive and negative work.
Bigland-Ritchie, B., & Woods, J. J. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011515 · Cited by 313
Fuglevand, A. J., Winter, D. A., Patla, A. E., & Stashuk, D. (1992) · Biological Cybernetics · doi:10.1007/bf00201021 · Cited by 311
Santello, M., Bianchi, M., Gabiccini, M., Ricciardi, E., Salvietti, G., Prattichizzo, D., Ernst, M., Moscatelli, A., Jörntell, H., Kappers, A. M. L., et al. (2016) · Physics of Life Reviews · doi:10.1016/j.plrev.2016.02.001 · Cited by 307
The Influence of Growth and Maturation on Stretch-Shortening Cycle Function in Youth
Radnor, J. M., Oliver, J. L., Waugh, C. M., Myer, G. D., Moore, I. S., & Lloyd, R. S. (2018) · Sports Medicine · doi:10.1007/s40279-017-0785-0 · Cited by 306
Optimal feedback control and the long-latency stretch response
Pruszynski, J. A., & Scott, S. H. (2012) · Experimental Brain Research · doi:10.1007/s00221-012-3041-8 · Cited by 295
Garnett, R., & Stephens, J. A. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013290 · Cited by 279
Lyons, K., Perry, J., Gronley, J. K., Barnes, L., & Antonelli, D. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1597 · Cited by 273
Andersen, L. L., Magnusson, S. P., Nielsen, M., Haleem, J., Poulsen, K., & Aagaard, P. (2006) · Physical Therapy · doi:10.1093/ptj/86.5.683 · Cited by 269
Fitting of Mathematical Functions to Biomechanical Data
Jackson, K. M. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326551 · Cited by 259
Teager–Kaiser Energy Operation of Surface EMG Improves Muscle Activity Onset Detection
Li, X., Zhou, P., & Aruin, A. S. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9320-z · Cited by 258
Ballistic contractions in fast or slow human muscles; discharge patterns of single motor units
Desmedt, J. E., & Godaux, E. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012566 · Cited by 178
Klein-Flügge, M. C., Kennerley, S. W., Saraiva, A. C., Penny, W. D., & Bestmann, S. (2015) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1004116 · Cited by 163
“For example the rate coding of muscle units changes little at low force levels, but increases more with increasing effort levels [66,67].”
BackgroundStable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160
Self-citationOnishi, H., Yagi, R., Akasaka, K., Momose, K., Ihashi, K., & Handa, Y. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00020-6 · Cited by 105
Enhanced H-reflex with resistance training is related to increased rate of force development
Holtermann, A., Roeleveld, K., Engstrøm, M., & Sand, T. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0503-y · Cited by 102
“Since the sEMG – torque relationship is quite linear during isometric contractions (Milner-Brown and Stein 1975), to obtain similar motor activity during the submaximal voluntary contractions with percutaneous stimula-”
Rapid Force Production in Children and Adults: Mechanical and Neural Contributions
WAUGH, C. M., KORFF, T., FATH, F., & BLAZEVICH, A. J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827a67ba · Cited by 97
Transducer‐based evaluation of tremor
Haubenberger, D., Abbruzzese, G., Bain, P. G., Bajaj, N., Benito‐León, J., Bhatia, K. P., Deuschl, G., Forjaz, M. J., Hallett, M., Louis, E. D., et al. (2016) · Movement Disorders · doi:10.1002/mds.26671 · Cited by 87
Hatze, H. (1977) · Biological Cybernetics · doi:10.1007/bf00357706 · Cited by 20
Metadata
- Authors
- Milner‐Brown, H. S., & Stein, R. B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1975-04
- Volume
- 246
- Issue
- 3
- Pages
- 549-569
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2045902658
- Cited by
- 644
- References
- 21
- FWCI
- 12.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.