The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Sensitivity of macaque retinal ganglion cells to chromatic and luminance flicker.
Open accessAbstract
1. We have studied the sensitivity of macaque retinal ganglion cells to sinusoidal flicker. Contrast thresholds were compared for stimuli which alternated only in luminance ('luminance flicker') or chromaticity ('chromatic flicker'), or which modulated only the middle‐ or long‐wavelength‐sensitive cones ('silent substitution'). 2. For luminance flicker, the lowest thresholds were those of phasic, non‐opponent ganglion cells. Sensitivity was maximal near 10 Hz. 3. Tonic, cone‐opponent ganglion cells were relatively insensitive to luminance flicker, especially at low temporal frequencies, but were sensitive to chromatic flicker, thresholds changing little from 1 to 20 Hz. Those with antagonistic input from middle‐ and long‐wavelength‐sensitive (M‐ and L‐) cones had a low threshold to chromatic flicker between red and green lights. Those with input from short‐wavelength‐sensitive (S‐) cones had a low threshold to chromatic flicker between blue and green. Expressed in terms of cone contrast, the S‐cone inputs to blue on‐centre cells had higher thresholds than M‐ and L‐cone inputs to other cell types. 4. Phasic, non‐opponent cells responded to high‐contrast red‐green chromatic flicker at twice the flicker frequency. This frequency‐doubled response is due to a non‐linearity of summation of M‐ and L‐cone mechanisms. It was only apparent at cone contrasts which were above threshold for most tonic cells. 5. M‐ or L‐cones were stimulated selectively using silent substitution. Thresholds of M‐ and L‐cone inputs to both red and green on‐centre cells were similar. This implies that these cells' sensitivity to chromatic flicker is derived in equal measure from centre and surround. Thresholds of the isolated cone inputs could be used to predict sensitivity to chromatic flicker. The high threshold of these cells to achromatic contrast is thus, at least in part, due to mutual cancellation by opponent inputs rather than intrinsically low sensitivity. 6. Thresholds of M‐ and L‐cone inputs to phasic cells were similar at 10 Hz, and were comparable to those of tonic cells, suggesting that at 1400 td cone inputs to both cell groups are of similar strength. 7. The modulation transfer function of phasic cells to luminance flicker was similar to the detection sensitivity curve of human observers who viewed the same stimulus. For chromatic flicker, at low temporal frequencies thresholds of tonic cells (red or green on‐centre cells in the case of red‐green flicker or blue on‐centre cells in the case of blue‐green flicker) approached that of human observers. We propose the different cell types are the substrate of different channels which have been postulated on the basis of psychophysical experiments. 8. At frequencies of chromatic flicker above 2 Hz, human sensitivity falls off steeply whereas tonic cell sensitivity remained the same or increased. This implies that high‐frequency signals in the chromatic, tonic cell pathway are not available to the central pathway respons
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chromatic mechanisms in lateral geniculate nucleus of macaque.
Derrington, A. M., Krauskopf, J., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015499 · Cited by 1,608
Spatial and chromatic interactions in the lateral geniculate body of the rhesus monkey.
Wiesel, T. N., & Hubel, D. H. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.6.1115 · Cited by 1,275
Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque.
Derrington, A. M., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015498 · Cited by 1,058
The contrast sensitivity of human colour vision to red‐green and blue‐yellow chromatic gratings.
Mullen, K. T. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015591 · Cited by 964
Retinal ganglion cells that project to the dorsal lateral geniculate nucleus in the macaque monkey
Perry, V. H., Oehler, R., & Cowey, A. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90006-x · Cited by 717
Functional properties of ganglion cells of the rhesus monkey retina.
De Monasterio, F. M., & Gouras, P. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011086 · Cited by 616
X and Y cells in the lateral geniculate nucleus of macaque monkeys.
Kaplan, E., & Shapley, R. M. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014333 · Cited by 601
Cat and monkey retinal ganglion cells and their visual functional roles
Shapley, R., & Hugh Perry, V. (1986) · Trends in Neurosciences · doi:10.1016/0166-2236(86)90064-0 · Cited by 588
Dreher, B., Fukada, Y., & Rodieck, R. W. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011429 · Cited by 548
Perceived velocity of moving chromatic gratings
Cavanagh, P., Tyler, C. W., & Favreau, O. E. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000893 · Cited by 391
Does colour provide an input to human motion perception?
RAMACHANDRAN, V. S., & GREGORY, R. L. (1978) · Nature · doi:10.1038/275055a0 · Cited by 304
Lee, B. B., Martin, P. R., & Valberg, A. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017292 · Cited by 291
Self-citationSize, scatter and coverage of ganglion cell receptive field centres in the cat retina.
Peichl, L., & Wässle, H. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012803 · Cited by 286
Properties of concentrically organized X and Y ganglion cells of macaque retina
de Monasterio, F. M. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.6.1394 · Cited by 281
Swanson, W. H., Ueno, T., Smith, V. C., & Pokorny, J. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001992 · Cited by 268
Spatiotemporal variation of chromatic and achromatic contrast thresholds
Kelly, D. H. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.000742 · Cited by 260
Psychophysical studies of monkey vision—I. Macaque luminosity and color vision tests
De Valois, R. L., Morgan, H. C., Polson, M. C., Mead, W. R., & Hull, E. M. (1974) · Vision Research · doi:10.1016/0042-6989(74)90116-3 · Cited by 248
Organization and post‐natal development of the monkey's lateral geniculate nucleus.
Blakemore, C., & Vital-Durand, F. (1986) · The Journal of Physiology · doi:10.1113/jphysiol.1986.sp016297 · Cited by 234
The responses of cells in macaque lateral geniculate nucleus to sinusoidal gratings.
Hicks, T. P., Lee, B. B., & Vidyasagar, T. R. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014619 · Cited by 230
Self-citationEnhancement of Luminance Flicker by Color-Opponent Mechanisms
Gouras, P., & Zrenner, E. (1979) · Science · doi:10.1126/science.109925 · Cited by 204
Two-band model of heterochromatic flicker
Kelly, D. H., & van Norren, D. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001081 · Cited by 190
Visual resolution of macaque retinal ganglion cells.
Crook, J. M., Lange-Malecki, B., Lee, B. B., & Valberg, A. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp016959 · Cited by 145
Self-citationJulesz, B., & Schumer, R. A. (1981) · Annual Review of Psychology · doi:10.1146/annurev.ps.32.020181.003043 · Cited by 144
Characteristics of the blue sensitive cone mechanism in primate retinal ganglion cells
Zrenner, E., & Gouras, P. (1981) · Vision Research · doi:10.1016/0042-6989(81)90042-0 · Cited by 109
Creutzfeldt, O. D., Lee, B. B., & Elepfandt, A. (1979) · Experimental Brain Research · doi:10.1007/bf00236770 · Cited by 95
Self-citationLee, B. B., Valberg, A., Tigwell, D. A., & Tryti, J. (1987) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1987.0021 · Cited by 89
Self-citationTransfer characteristics of excitation and inhibition in cat retinal ganglion cells.
Maffei, L., Cervetto, L., & Fiorentini, A. (1970) · Journal of Neurophysiology · doi:10.1152/jn.1970.33.2.276 · Cited by 68
Amplitude and phase of responses of macaque retinal ganglion cells to flickering stimuli.
Lee, B. B., Martin, P. R., & Valberg, A. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017686 · Cited by 65
Self-citationCleland, B. G., & Enroth‐Cugell, C. (1966) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1966.tb03438.x · Cited by 41
Grüsser, O. ‐. (1971) · Vision Research · doi:10.1016/0042-6989(71)90034-4 · Cited by 32
Cited by
How parallel are the primate visual pathways?
Merigan, W. H., & Maunsell, J. H. R. (1993) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.16.030193.002101 · Cited by 1,597
Receptor noise as a determinant of colour thresholds
Vorobyev, M., & Osorio, D. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0302 · Cited by 1,266
Physiological and anatomical evidence for a magnocellular defect in developmental dyslexia.
Livingstone, M. S., Rosen, G. D., Drislane, F. W., & Galaburda, A. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.18.7943 · Cited by 1,018
Luminance and chromatic modulation sensitivity of macaque ganglion cells and human observers
Lee, B. B., Pokorny, J., Martin, P. R., Valbergt, A., & Smith, V. C. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.002223 · Cited by 504
Self-citationParallel Pathways for Spectral Coding in Primate Retina
Dacey, D. M. (2000) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.23.1.743 · Cited by 440
Metadata
- Authors
- Lee, B. B., Martin, P. R., & Valberg, A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1989-07
- Volume
- 414
- Issue
- 1
- Pages
- 223-243
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2054266716
- Cited by
- 310
- References
- 30
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.