Fluctuations in blood flow to acral skin in humans: connection with heart rate and blood pressure variability.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Spontaneous fluctuations in blood flow in arteries supplying acral skin were investigated with Doppler ultrasound in human subjects. Finger blood pressure, heart rate (HR) and cardiac output were measured simultaneously and noninvasively. 2. Synchronous fluctuations in flow were found in arteries supplying the hands and feet. The fluctuations were larger and more rapid than the flow variations which have been demonstrated with other methods. The magnitude of the total flow fluctuations in the hands and feet was estimated to be 5‐10% of cardiac output in resting subjects. This range of flow fluctuations is made possible by spontaneous opening and closing of skin arteriovenous anastomoses (AVAs). 3. The fluctuations in skin blood flow were accompanied by inverse fluctuations in mean blood pressure (MAP). The power spectra of skin vascular conductance and MAP both contained maximum intensity at low frequencies, below 0.15 Hz, with high coherence. 4. The central circulatory events connected with the skin blood flow fluctuations were calculated from the experimental data with the use of transfer function analysis. There was a rise in HR, cardiac output and MAP starting 1‐4 s before a cutaneous vasoconstriction. This indicates that the HR and MAP responses are not only passive effects of changes in peripheral resistance, but are the result of a simultaneous activation of the peripheral vascular and cardiac efferent branches of the autonomic nervous system. The HR and MAP responses are then modified, probably by baroreceptor activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Cited by
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
Cutaneous Vasodilator and Vasoconstrictor Mechanisms in Temperature Regulation
Johnson, J. M., Minson, C. T., & Kellogg, D. L. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130015 · Cited by 414
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
Nilsson, L., Goscinski, T., Kalman, S., Lindberg, L. ‐., & Johansson, A. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01375.x · Cited by 88
Metadata
- Authors
- Lossius, K., Eriksen, M., & Walløe, L.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 460
- Issue
- 1
- Pages
- 641-655
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1992010926
- Cited by
- 133
- References
- 1
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.