Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record.

Regional fibre stress‐fibre strain area as an estimate of regional blood flow and oxygen demand in the canine heart.

Open access
Delhaas, T, Arts, T, Prinzen, F W, Reneman, R S · 1994 · The Journal of Physiology

Abstract

1. In the present study the relation between regional left ventricular contractile work, regional myocardial blood flow and oxygen uptake was assessed during asynchronous electrical activation. 2. In analogy to the use of the pressure‐volume area for the estimation of global oxygen demand, the fibre stress‐fibre strain area, as assessed regionally, was used to estimate regional oxygen demand. The more often used relation between the pressure‐sarcomere length area and regional oxygen demand was also assessed. 3. Experiments were performed in six anaesthetized dogs with open chests. Regional differences in mechanical work were generated by asynchronous electrical activation of the myocardial wall. The ventricles were paced from the right atrium, the left ventricular free wall, the left ventricular apex or the right ventricular outflow tract. Regional fibre strain was measured at the epicardial anterior left ventricular free wall with a two‐dimensional video technique. 4. Regional fibre stress was estimated from left ventricular pressure, the ratio of left ventricular cavity volume to wall volume, and regional deformation. Total mechanical power (TMP) was calculated from the fibre stress‐fibre strain area (SSA) and the duration of the cardiac cycle (tcycle) using the equation: TMP = SSA/tcycle. Regional myocardial blood flow was measured with radioactive microspheres. Regional oxygen uptake was estimated from regional myocardial blood flow values and arteriovenous differences in oxygen content. 5. During asynchronous electrical activation, total mechanical power, pressure‐sarcomere length area, myocardial blood flow and oxygen uptake were significantly lower in early than in late activated regions (P < 0.05). 6. Within the experiments, the correlation between the pressure‐sarcomere length area and regional oxygen uptake was not significantly lower than the one between total mechanical power (TMP) and regional oxygen uptake (VO2,reg). However, variability of this relation between the experiments was less for total mechanical power. Pooling all experimental data revealed: VO2,reg = k1 TMP+k2, with k1 = 4.94 +/‐ 0.31 mol J‐1 k2 = 24.2 +/‐ 1.9 mmol m‐3 s‐1 (means +/‐ standard error of the estimate). 7. This relation is in quantitative agreement with previously reported relations between the pressure‐volume area and global oxygen demand. The results indicate that asynchronous electrical activation causes a redistribution of mechanical work and oxygen demand and that regional total mechanical power is a better and more general estimate of regional oxygen demand than the regional pressure‐sarcomere length area.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1994.sp020209

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Delhaas, T., Arts, T., Prinzen, F. W., & Reneman, R. S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1994-06-15
Volume
477
Issue
3
Pages
481-496
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2110338499
Cited by
181
References
0
FWCI
2.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.