Cited by 240Neuroscience and Neural EngineeringCardiac pacing and defibrillation studiesOrthopaedic implants and arthroplasty

The DOI matches its Crossref record; 30 of the 31 references it cites were found in a registry or an index.

Criteria for the Selection of Materials for Implanted Electrodes

Geddes, L. A., Roeder, R.·2003·Annals of Biomedical Engineering

Abstract

There are four criteria that must be considered when choosing material for an implanted electrode: (1) tissue response, (2) allergic response, (3) electrode-tissue impedance, and (4) radiographic visibility. This paper discusses these four criteria and identifies the materials that are the best candidates for such electrodes. For electrodes that make ohmic contact with tissues: gold, platinum, platinum-iridium, tungsten, and tantalum are good candidates. The preferred insulating materials are polyimide and glass. The characteristics of stimulator output circuits and the importance of the bidirectional waveform in relation to electrode decomposition are discussed. The paper concludes with an analysis, the design criteria, and the special properties and materials for capacitive recording and stimulating electrodes.

Overview

Integrity signals

Registry

Crossref · 10.1114/1.1581292

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Cited by

Sorted by citations

Items 201–240 of 240

Metadata

Authors
Geddes, L. A., & Roeder, R.
Affiliations
Purdue University West Lafayette (US)
Venue
Annals of Biomedical Engineering
Published
2003-07
Volume
31
Issue
7
Pages
879-890
ISSN
0090-6964 (ISSN-L)
OpenAlex
W1978696561
Cited by
240
References
31
Citations by year
2026: 5 · 2025: 5 · 2024: 12 · 2023: 8 · 2022: 13 · 2021: 18 · 2020: 19 · 2019: 21 · 2018: 20 · 2017: 15 · 2016: 19 · 2015: 11 · 2014: 18 · 2013: 7 · 2012: 8
FWCI
0.92
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
implanted electrodes, electrode materials, tissue reaction, allergic reactions, gold, platinum, tungsten, tantalum, polyimide, glass insulators
MeSH terms
Biocompatible Materials, Decision Support Techniques, Electrodes, Implanted, Electrophysiology, Equipment Design, Hypersensitivity, Materials Testing, Microelectrodes, Technology Assessment, Biomedical, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review