The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Dynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study
Abstract
The validation of two noninvasive methods for measuring the dynamic three-dimensional kinematics of the human scapula with a magnetic tracking device is presented. One method consists of simply fixing a sensor directly to the acromion and the other consists of mounting a sensor to an adjustable plastic jig that fits over the scapular spine and acromion. The concurrent validity of both methods was assessed separately by comparison with data collected simultaneously from an invasive approach in which pins were drilled directly into the scapula. The differences between bone and skin based measurements represents an estimation of skin motion artifact. The average motion pattern of each surface method was similar to that measured by the invasive technique, especially below 120 degrees of elevation. These results indicate that with careful consideration, both methods may offer reasonably accurate representations of scapular motion that may be used to study shoulder pathologies and help develop computational models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludewig, P. M., & Cook, T. M. (2000) · Physical Therapy · doi:10.1093/ptj/80.3.276 · Cited by 1,655
Normal and abnormal motion of the shoulder
Poppen, N., & Walker, P. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658020-00006 · Cited by 885
Position and orientation in space of bones during movement: experimental artefacts
Cappozzo, A., Catani, F., Leardini, A., Benedetti, M., & Della Croce, U. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00046-1 · Cited by 756
Lukasiewicz, A. C., McClure, P., Michener, L., Pratt, N., Sennett, B., Ludewig, P., Lukasiewicz, A. C., McClure, P., Michener, L., Pratt, N., et al. (1999) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1999.29.10.574 · Cited by 675
Self-citationA Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics
Andriacchi, T. P., Alexander, E. J., Toney, M. K., Dyrby, C., & Sum, J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834888 · Cited by 495
Effect of skin movement on the analysis of skeletal knee joint motion during running
Reinschmidt, C., van den Bogert, A. J., Nigg, B. M., Lundberg, A., & Murphy, N. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00001-8 · Cited by 475
Ludewig, P. M., Cook, T. M., & Nawoczenski, D. A. (1996) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1996.24.2.57 · Cited by 424
P. WARNER, J. J., MICHELI, L. J., ARSLANIAN, L. E., KENNEDY, J., & KENNEDY, R. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199212000-00024 · Cited by 352
Freedman, L., & Munro, R. R. (1966) · PubMed · Cited by 297
Tibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers
Reinschmidt, C., van den Bogert, A. J., Lundberg, A., Nigg, B. M., Murphy, N., Stacoff, A., & Stano, A. (1997) · Gait & Posture · doi:10.1016/s0966-6362(97)01110-7 · Cited by 257
Cited by
The Association of Scapular Kinematics and Glenohumeral Joint Pathologies
Ludewig, P. M., & Reynolds, J. F. (2009) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2009.2808 · Cited by 944
Anatomical and biomechanical mechanisms of subacromial impingement syndrome
Michener, L. A., McClure, P. W., & Karduna, A. R. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(03)00047-0 · Cited by 727
Self-citationDirect 3-dimensional measurement of scapular kinematics during dynamic movements in vivo
McClure, P. W., Michener, L. A., Sennett, B. J., & Karduna, A. R. (2001) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2001.112954 · Cited by 721
Self-citationMotion of the Shoulder Complex During Multiplanar Humeral Elevation
Ludewig, P. M., Phadke, V., Braman, J. P., Hassett, D. R., Cieminski, C. J., & LaPrade, R. F. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01483 · Cited by 654
ARMin III – Arm Therapy Exoskeleton with an Ergonomic Shoulder Actuation
Nef, T., Guidali, M., & Riener, R. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902840179 · Cited by 522
McClure, P. W., Michener, L. A., & Karduna, A. R. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1075 · Cited by 495
Self-citationA Clinical Method for Identifying Scapular Dyskinesis, Part 1: Reliability
McClure, P., Tate, A. R., Kareha, S., Irwin, D., & Zlupko, E. (2009) · Journal of Athletic Training · doi:10.4085/1062-6050-44.2.160 · Cited by 493
Self-citationBorstad, J. D., & Ludewig, P. M. (2005) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2005.35.4.227 · Cited by 489
Evaluation of Clinical Assessment Methods for Scapular Dyskinesis
Uhl, T. L., Kibler, W. B., Gecewich, B., & Tripp, B. L. (2009) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2009.06.007 · Cited by 392
Hsu, Y.-H., Chen, W.-Y., Lin, H.-C., Wang, W. T. J., & Shih, Y.-F. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.11.003 · Cited by 388
Complete 3D kinematics of upper extremity functional tasks
van Andel, C. J., Wolterbeek, N., Doorenbosch, C. A. M., Veeger, D. (. E. J. )., & Harlaar, J. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.03.002 · Cited by 351
McClure, P. W., Bialker, J., Neff, N., Williams, G., & Karduna, A. (2004) · Physical Therapy · doi:10.1093/ptj/84.9.832 · Cited by 341
Self-citationAmbulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311
Head and shoulder posture affect scapular mechanics and muscle activity in overhead tasks
Thigpen, C. A., Padua, D. A., Michener, L. A., Guskiewicz, K., Giuliani, C., Keener, J. D., & Stergiou, N. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.12.003 · Cited by 305
Self-citationBey, M. J., Zauel, R., Brock, S. K., & Tashman, S. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2206199 · Cited by 300
Effects of Upper Trunk Rotation on Shoulder Joint Torque among Baseball Pitchers of Various Levels
Aguinaldo, A. L., Buttermore, J., & Chambers, H. (2007) · Journal of Applied Biomechanics · doi:10.1123/jab.23.1.42 · Cited by 296
Borsa, P. A., Laudner, K. G., & Sauers, E. L. (2008) · Sports Medicine · doi:10.2165/00007256-200838010-00003 · Cited by 268
Tibiofemoral joint contact forces and knee kinematics during squatting
Smith, S. M., Cockburn, R. A., Hemmerich, A., Li, R. M., & Wyss, U. P. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.05.004 · Cited by 72
Helgadottir, H., Kristjansson, E., Mottram, S., Karduna, A., & Jonsson, H. (2011) · Journal of Applied Biomechanics · doi:10.1123/jab.27.3.181 · Cited by 63
Self-citationReliability and precision of 3D wireless measurement of scapular kinematics
van den Noort, J. C., Wiertsema, S. H., Hekman, K. M. C., Schönhuth, C. P., Dekker, J., & Harlaar, J. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1186-2 · Cited by 60
Biomechanical measures in participants with shoulder pain: Intra-rater reliability
Michener, L. A., Elmore, K. A., Darter, B. J., & Timmons, M. K. (2016) · Manual Therapy · doi:10.1016/j.math.2015.10.011 · Cited by 18
Self-citation
Metadata
- Authors
- Karduna, A. R., McClure, P. W., Michener, L. A., & Sennett, B.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2000-12-01
- Volume
- 123
- Issue
- 2
- Pages
- 184-190
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1984745520
- Cited by
- 622
- References
- 24
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.