Quantitative Computed Tomography-Based Finite Element Models of the Human Lumbar Vertebral Body: Effect of Element Size on Stiffness, Damage, and Fracture Strength Predictions
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This study investigated the numerical convergence characteristics of specimen-specific “voxel-based” finite element models of 14 excised human cadaveric lumbar vertebral bodies (age: 37–87; M=6, F=8) that were generated automatically from clinical-type CT scans. With eventual clinical applications in mind, the ability of the model stiffness to predict the experimentally measured compressive fracture strength of the vertebral bodies was also assessed. The stiffness of “low”-resolution models (3×3×3 mm element size) was on average only 4% greater p=0.03 than for “high”-resolution models (1×1×1.5 mm) despite interspecimen variations that varied over four-fold. Damage predictions using low- vs high-resolution models were significantly different p=0.01 at loads corresponding to an overall strain of 0.5%. Both the high r2=0.94 and low r2=0.92 resolution model stiffness values were highly correlated with the experimentally measured ultimate strength values. Because vertebral stiffness variations in the population are much greater than those that arise from differences in voxel size, these results indicate that imaging resolution is not critical in cross-sectional studies of this parameter. However, longitudinal studies that seek to track more subtle changes in stiffness over time should account for the small but highly significant effects of voxel size. These results also demonstrate that an automated voxel-based finite element modeling technique may provide an excellent noninvasive assessment of vertebral strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationMosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Mechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155
Self-citationBiomechanical consequences of an isolated overload on the human vertebral body
Kopperdahl, D. L., Pearlman, J. L., & Keaveny, T. M. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180502 · Cited by 120
Self-citation
Cited by
FEBio: Finite Elements for Biomechanics
Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005694 · Cited by 1,105
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Self-citationUral, A., & Vashishth, D. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2768377 · Cited by 62
Elastic Anisotropy of Trabecular Bone in the Elderly Human Vertebra
Unnikrishnan, G. U., Gallagher, J. A., Hussein, A. I., Barest, G. D., & Morgan, E. F. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4031415 · Cited by 13
Metadata
- Authors
- Crawford, R. P., Rosenberg, W. S., & Keaveny, T. M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2003-08-01
- Volume
- 125
- Issue
- 4
- Pages
- 434-438
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2133962671
- Cited by
- 121
- References
- 5
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Computed Tomography-Based Finite Element Models of the Human Lumbar Vertebral Body: Effect of Element Size on Stiffness, Damage, and Fracture Strength Predictions. https://app.cochat.ai/papers/10.1115/1.1589772
- The paper
- Crawford, R. P., Rosenberg, W. S., & Keaveny, T. M. (2003). Quantitative Computed Tomography-Based Finite Element Models of the Human Lumbar Vertebral Body: Effect of Element Size on Stiffness, Damage, and Fracture Strength Predictions. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1589772
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.