The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies
Abstract
A better understanding of the three-dimensional mechanics of the pelvis, at the patient-specific level, may lead to improved treatment modalities. Although finite element (FE) models of the pelvis have been developed, validation by direct comparison with subject-specific strains has not been performed, and previous models used simplifying assumptions regarding geometry and material properties. The objectives of this study were to develop and validate a realistic FE model of the pelvis using subject-specific estimates of bone geometry, location-dependent cortical thickness and trabecular bone elastic modulus, and to assess the sensitivity of FE strain predictions to assumptions regarding cortical bone thickness as well as bone and cartilage material properties. A FE model of a cadaveric pelvis was created using subject-specific computed tomography image data. Acetabular loading was applied to the same pelvis using a prosthetic femoral stem in a fashion that could be easily duplicated in the computational model. Cortical bone strains were monitored with rosette strain gauges in ten locations on the left hemipelvis. FE strain predictions were compared directly with experimental results for validation. Overall, baseline FE predictions were strongly correlated with experimental results (r2=0.824), with a best-fit line that was not statistically different than the line y=x(experimental strains=FEpredicted strains). Changes to cortical bone thickness and elastic modulus had the largest effect on cortical bone strains. The FE model was less sensitive to changes in all other parameters. The methods developed and validated in this study will be useful for creating and analyzing patient-specific FE models to better understand the biomechanics of the pelvis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Theory of Large Elastic Deformation
Mooney, M. (1940) · Journal of Applied Physics · doi:10.1063/1.1712836 · Cited by 3,580
Hip contact forces and gait patterns from routine activities
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00040-9 · Cited by 2,215
The Etiology of Osteoarthritis of the Hip: An Integrated Mechanical Concept
Ganz, R., Leunig, M., Leunig-Ganz, K., & Harris, W. H. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-007-0060-z · Cited by 1,620
Schroeder, W. J., Zarge, J. A., & Lorensen, W. E. (1992) · Proceedings of the 19th annual conference on Computer graphics and interactive techniques · doi:10.1145/133994.134010 · Cited by 1,464
Hip joint loading during walking and running, measured in two patients
Bergmann, G., Graichen, F., & Rohlmann, A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90058-m · Cited by 1,276
Generalization of selective integration procedures to anisotropic and nonlinear media
Hughes, T. J. R. (1980) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620150914 · Cited by 923
Schroeder, W. J., Zarge, J. A., & Lorensen, W. E. (1992) · ACM SIGGRAPH Computer Graphics · doi:10.1145/142920.134010 · Cited by 692
Etiology of Osteoarthritis of the Hip
HARRIS, W. H. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198612000-00004 · Cited by 677
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
The mechanical properties of bone.
Evans, F. G. (1969) · PubMed · Cited by 587
The Aetiology of Primary Osteoarthritis of the Hip
Murray, R. O. (1965) · The British Journal of Radiology · doi:10.1259/0007-1285-38-455-810 · Cited by 587
Parfitt, A. M. (1984) · Calcified Tissue International · doi:10.1007/bf02406145 · Cited by 441
Mechanical and textural properties of pelvic trabecular bone
Dalstra, M., Huiskes, R., Odgaard, A., & van Erning, L. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90014-6 · Cited by 358
Patterns of osteoarthritis of the hip
Solomon, L. (1976) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.58b2.932079 · Cited by 333
Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone
Dalstra, M., Huiskes, R., & van Erning, L. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794181 · Cited by 303
Estimation of mechanical properties of cortical bone by computed tomography
Snyder, S. M., & Schneider, E. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090315 · Cited by 291
Contact pressures in the human hip joint
Afoke, N., Byers, P., & Hutton, W. (1987) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.69b4.3611154 · Cited by 268
Prevrhal, S., Engelke, K., & Kalender, W. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/017 · Cited by 226
High-resolution MRI detects cartilage swelling at the early stages of experimental osteoarthritis
Calvo, E., Palacios, I., Delgado, E., Ruiz-Cabello, J., Hernández, P., Sánchez-Pernaute, O., Egido, J., & Herrero-Beaumont, G. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2001.0413 · Cited by 158
Stress distributions in the acetabular region—I. Before and after total joint replacement
Vasu, R., Carter, D. R. P., & Harris, W. H. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90247-0 · Cited by 127
Mathematical estimation of stress distribution in normal and dysplastic human hips
Mavčič, B., Pompe, B., Antolič, V., Daniel, M., Iglič, A., & Kralj‐Iglič, V. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00014-1 · Cited by 118
CONTACT PRESSURES IN THE LOADED HUMAN CADAVER HIP
Day, W. H., Swanson, S. A. V., & Freeman, M. A. R. (1975) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.57b3.302 · Cited by 112
Influence of phantom diameter, kVp and scan mode upon computed tomography dose index
Nickoloff, E. L., Dutta, A. K., & Lu, Z. F. (2003) · Medical Physics · doi:10.1118/1.1543149 · Cited by 106
Radiographic evaluation of osteoarthritis
Gupta, K. B., Duryea, J., & Weissman, B. N. (2004) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(03)00169-6 · Cited by 101
Contact finite element stress analysis of the hip joint
Rapperport, D. J., Carter, D. R. P., & Schurman, D. J. (1985) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100030406 · Cited by 77
Comparative study of iliac crest and subchondral femoral bone in osteoarthritic patients
Fazzalari, N. L., Moore, R. J., Manthey, B. A., & Vernon-Roberts, B. (1992) · Bone · doi:10.1016/8756-3282(92)90079-c · Cited by 30
Cited by
FEBio: Finite Elements for Biomechanics
Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005694 · Cited by 1,105
Self-citationSubject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Validation of Finite Element Predictions of Cartilage Contact Pressure in the Human Hip Joint
Anderson, A. E., Ellis, B. J., Maas, S. A., Peters, C. L., & Weiss, J. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2953472 · Cited by 275
Self-citationUral, A., & Vashishth, D. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2768377 · Cited by 62
Metadata
- Authors
- Anderson, A. E., Peters, C. L., Tuttle, B. D., & Weiss, J. A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2005-02-04
- Volume
- 127
- Issue
- 3
- Pages
- 364-373
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2145084036
- Cited by
- 347
- References
- 26
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.