The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Robust Strategies for Automated AFM Force Curve Analysis—I. Non-adhesive Indentation of Soft, Inhomogeneous Materials
Abstract
The atomic force microscope (AFM) has found wide applicability as a nanoindentation tool to measure local elastic properties of soft materials. An automated approach to the processing of AFM indentation data, namely, the extraction of Young’s modulus, is essential to realizing the high-throughput potential of the instrument as an elasticity probe for typical soft materials that exhibit inhomogeneity at microscopic scales. This paper focuses on Hertzian analysis techniques, which are applicable to linear elastic indentation. We compiled a series of synergistic strategies into an algorithm that overcomes many of the complications that have previously impeded efforts to automate the fitting of contact mechanics models to indentation data. AFM raster data sets containing up to 1024 individual force-displacement curves and macroscopic compression data were obtained from testing polyvinyl alcohol gels of known composition. Local elastic properties of tissue-engineered cartilage were also measured by the AFM. All AFM data sets were processed using customized software based on the algorithm, and the extracted values of Young’s modulus were compared to those obtained by macroscopic testing. Accuracy of the technique was verified by the good agreement between values of Young’s modulus obtained by AFM and by direct compression of the synthetic gels. Validation of robustness was achieved by successfully fitting the vastly different types of force curves generated from the indentation of tissue-engineered cartilage. For AFM indentation data that are amenable to Hertzian analysis, the method presented here minimizes subjectivity in preprocessing and allows for improved consistency and minimized user intervention. Automated, large-scale analysis of indentation data holds tremendous potential in bioengineering applications, such as high-resolution elasticity mapping of natural and artificial tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface energy and the contact of elastic solids
Johnson, K. L., Kendall, K., & Roberts, A. D. (1971) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1971.0141 · Cited by 8,061
Effect of contact deformations on the adhesion of particles
Derjaguin, B. V., Muller, V. M., & Toporov, Y. P. (1975) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(75)90018-1 · Cited by 4,589
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
The Physics of Rubber Elasticity
Treloar, L. R. G., & Montgomery, D. J. (1959) · Physics Today · doi:10.1063/1.3060678 · Cited by 3,787
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Determination of Elastic Moduli of Thin Layers of Soft Material Using the Atomic Force Microscope
Dimitriadis, E. K., Horkay, F., Maresca, J., Kachar, B., & Chadwick, R. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75620-8 · Cited by 1,230
Self-citationIntroduction to polymer viscoelasticity
(2005) · Choice Reviews Online · doi:10.5860/choice.43-2216 · Cited by 980
Microrheology of Human Lung Epithelial Cells Measured by Atomic Force Microscopy
Alcaraz, J., Buscemi, L., Grabulosa, M., Trepat, X., Fabry, B., Farré, R., & Navajas, D. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75014-0 · Cited by 740
Muller, V. M., Yushchenko, V. S., & Derjaguin, B. V. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90419-1 · Cited by 738
Measuring the Elastic Properties of Thin Polymer Films with the Atomic Force Microscope
Domke, J., & Radmacher, M. (1998) · Langmuir · doi:10.1021/la9713006 · Cited by 636
Mathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589
Relative Microelastic Mapping of Living Cells by Atomic Force Microscopy
A-Hassan, E., Heinz, W. F., Antonik, M. D., D’Costa, N. P., Nageswaran, S., Schoenenberger, C.-A., & Hoh, J. H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77868-3 · Cited by 552
Nanoscale Mapping of the Elasticity of Microbial Cells by Atomic Force Microscopy
Touhami, A., Nysten, B., & Dufrêne, Y. F. (2003) · Langmuir · doi:10.1021/la034136x · Cited by 466
Comparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
Rotsch, C., Jacobson, K., & Radmacher, M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.3.921 · Cited by 437
Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D. (2005) · Physical Review E · doi:10.1103/physreve.72.021914 · Cited by 421
Measuring the elastic properties of biological samples with the AFM
Radmacher, M. (1997) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.582176 · Cited by 417
Imaging and manipulation of biological structures with the AFM
Fotiadis, D. (2002) · Micron · doi:10.1016/s0968-4328(01)00026-9 · Cited by 390
Measuring the Elastic Properties of Living Cells by the Atomic Force Microscope
Radmacher, M. (2002) · Methods in Cell Biology · doi:10.1016/s0091-679x(02)68005-7 · Cited by 311
A method for determining the spring constant of cantilevers for atomic force microscopy
Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/2/010 · Cited by 282
Bilodeau, G. G. (1992) · Journal of Applied Mechanics · doi:10.1115/1.2893754 · Cited by 265
Costa, K. D., & Yin, F. C. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835074 · Cited by 265
Measuring the microelastic properties of biological material
Tao, N. J., Lindsay, S. M., & Lees, S. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81692-2 · Cited by 210
Sun, Y., Akhremitchev, B., & Walker, G. C. (2004) · Langmuir · doi:10.1021/la036461q · Cited by 201
Molecular Recognition Imaging and Force Spectroscopy of Single Biomolecules
Kienberger, F., Ebner, A., Gruber, H. J., & Hinterdorfer, P. (2006) · Accounts of Chemical Research · doi:10.1021/ar050084m · Cited by 191
Schaer-Zammaretti, P., & Ubbink, J. (2003) · Ultramicroscopy · doi:10.1016/s0304-3991(03)00044-5 · Cited by 166
Lin, D. C., Dimitriadis, E. K., & Horkay, F. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2800826 · Cited by 162
Self-citationAlmqvist, N., Bhatia, R., Primbs, G., Desai, N., Banerjee, S., & Lal, R. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74243-5 · Cited by 150
Sample preparation procedures for biological atomic force microscopy
EL KIRAT, K., BURTON, I., DUPRES, V., & DUFRENE, Y. F. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01480.x · Cited by 130
Poisson's ratio of poly(vinyl alcohol) gels
Urayama, K., Takigawa, T., & Masuda, T. (1993) · Macromolecules · doi:10.1021/ma00064a016 · Cited by 109
Strategies and results of atomic force microscopy in the study of cellular adhesion
Simon, A., & Durrieu, M. (2005) · Micron · doi:10.1016/j.micron.2005.06.006 · Cited by 72
Hutter, J. L., CHEN, J., WAN, W. K., Uniyal, S., Leabu, M., & Chan, B. M. C. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01497.x · Cited by 71
Measurement and Characterization of Whole-Cell Mechanical Behavior
Jaasma, M., Jackson, W. M., & Keaveny, T. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9081-0 · Cited by 45
Single‐Molecule Studies on DNA and RNA
Greulich, K. O. (2005) · ChemPhysChem · doi:10.1002/cphc.200500038 · Cited by 35
Imaging Proteins with Atomic Force Microscopy: An Overview
Silva, L. P. (2005) · Current Protein and Peptide Science · doi:10.2174/1389203054546389 · Cited by 27
Cited by
Wolf, K., te Lindert, M., Krause, M., Alexander, S., te Riet, J., Willis, A. L., Hoffman, R. M., Figdor, C. G., Weiss, S. J., & Friedl, P. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201210152 · Cited by 1,375
Pectin-Induced Changes in Cell Wall Mechanics Underlie Organ Initiation in Arabidopsis
Peaucelle, A., Braybrook, S. A., Le Guillou, L., Bron, E., Kuhlemeier, C., & Höfte, H. (2011) · Current Biology · doi:10.1016/j.cub.2011.08.057 · Cited by 633
Alessandri, K., Sarangi, B. R., Gurchenkov, V. V., Sinha, B., Kießling, T. R., Fetler, L., Rico, F., Scheuring, S., Lamaze, C., Simon, A., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1309482110 · Cited by 460
The soft mechanical signature of glial scars in the central nervous system
Moeendarbary, E., Weber, I. P., Sheridan, G. K., Koser, D. E., Soleman, S., Haenzi, B., Bradbury, E. J., Fawcett, J., & Franze, K. (2017) · Nature Communications · doi:10.1038/ncomms14787 · Cited by 406
Swelling‐Induced Surface Patterns in Hydrogels with Gradient Crosslinking Density
Guvendiren, M., Yang, S., & Burdick, J. A. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200900622 · Cited by 351
Metadata
- Authors
- Lin, D. C., Dimitriadis, E. K., & Horkay, F.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2006-11-15
- Volume
- 129
- Issue
- 3
- Pages
- 430-440
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2129314813
- Cited by
- 324
- References
- 36
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.