The DOI matches its Crossref record.
Impedance Control: An Approach to Manipulation: Part II—Implementation
Abstract
This three-part paper presents an approach to the control of dynamic interaction between a manipulator and its environment. Part I presented the theoretical reasoning behind impedance control. In Part II the implementation of impedance control is considered. A feedback control algorithm for imposing a desired cartesian impedance on the end-point of a nonlinear manipulator is presented. This algorithm completely eliminates the need to solve the “inverse kinematics problem” in robot motion control. The modulation of end-point impedance without using feedback control is also considered, and it is shown that apparently “redundant” actuators and degrees of freedom such as exist in the primate musculoskeletal system may be used to modulate end-point impedance and may play an essential functional role in the control of dynamic interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Villani, V., Pini, F., Leali, F., & Secchi, C. (2018) · Mechatronics · doi:10.1016/j.mechatronics.2018.02.009 · Cited by 1,237
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“A leading theory regarding physiological movement is that the CNS controls th e limbs through impedance control [204,205].”
BackgroundA design framework for teleoperators with kinesthetic feedback
Hannaford, B. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.88057 · Cited by 926
Progress and prospects of the human–robot collaboration
Ajoudani, A., Zanchettin, A. M., Ivaldi, S., Albu-Schäffer, A., Kosuge, K., & Khatib, O. (2018) · Autonomous Robots · doi:10.1007/s10514-017-9677-2 · Cited by 832
Adaptive Neural Impedance Control of a Robotic Manipulator With Input Saturation
He, W., Dong, Y., & Sun, C. (2016) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2015.2429555 · Cited by 790
Adaptive Fuzzy Neural Network Control for a Constrained Robot Using Impedance Learning
He, W., & Dong, Y. (2018) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2017.2665581 · Cited by 642
Wensing, P. M., Wang, A., Seok, S., Otten, D., Lang, J., & Kim, S. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2640183 · Cited by 472
Hentout, A., Aouache, M., Maoudj, A., & Akli, I. (2019) · Advanced Robotics · doi:10.1080/01691864.2019.1636714 · Cited by 462
Variable Stiffness Actuators: Review on Design and Components
Wolf, S., Grioli, G., Eiberger, O., Friedl, W., Grebenstein, M., Hoppner, H., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M. G., et al. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2501019 · Cited by 459
ARMin: a robot for patient-cooperative arm therapy
Nef, T., Mihelj, M., & Riener, R. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0226-6 · Cited by 445
Modeling of Force Sensing and Validation of Disturbance Observer for Force Control
Katsura, S., Matsumoto, Y., & Ohnishi, K. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885459 · Cited by 397
Force and position control of manipulators during constrained motion tasks
Mills, J. K., & Goldenberg, A. A. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.88015 · Cited by 385
Learning variable impedance control
Buchli, J., Stulp, F., Theodorou, E., & Schaal, S. (2011) · The International Journal of Robotics Research · doi:10.1177/0278364911402527 · Cited by 337
Zollo, L., Roccella, S., Guglielmelli, E., Carrozza, M. C., & Dario, P. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901936 · Cited by 335
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Wong, A. L., Haith, A. M., & Krakauer, J. W. (2015) · The Neuroscientist · doi:10.1177/1073858414541484 · Cited by 254
Dentronics: Towards robotics and artificial intelligence in dentistry
Grischke, J., Johannsmeier, L., Eich, L., Griga, L., & Haddadin, S. (2020) · Dental Materials · doi:10.1016/j.dental.2020.03.021 · Cited by 221
A Comprehensive Realization of Robot Skin: Sensors, Sensing, Control, and Applications
Cheng, G., Dean-Leon, E., Bergner, F., Rogelio Guadarrama Olvera, J., Leboutet, Q., & Mittendorfer, P. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2933348 · Cited by 209
Metadata
- Authors
- Hogan, N.
- Venue
- Journal of Dynamic Systems, Measurement, and Control
- Publisher
- ASME International
- Published
- 1985-03-01
- Volume
- 107
- Issue
- 1
- Pages
- 8-16
- ISSN
- 0022-0434 (ISSN-L)
- 1528-9028
- OpenAlex
- W2017239762
- Cited by
- 973
- References
- 0
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.