Optimization of Inertial Sensor-Based Motion Capturing for Magnetically Distorted Field Applications
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Inertial measurement units (IMU) are gaining increasing importance for human motion tracking in a large variety of applications. IMUs consist of gyroscopes, accelerometers, and magnetometers which provide angular rate, acceleration, and magnetic field information, respectively. In scenarios with a permanently distorted magnetic field, orientation estimation algorithms revert to using only angular rate and acceleration information. The result is an increasing drift error of the heading information. This article describes a method to compensate the orientation drift of IMUs using angular rate and acceleration readings in a quaternion-based algorithm. Zero points (ZP) were introduced, which provide additional heading and gyroscope bias information and were combined with bidirectional orientation computation. The necessary frequency of ZPs to achieve an acceptable error level is derived in this article. In a laboratory environment the method and the effect of varying interval length between ZPs was evaluated. Eight subjects were equipped with seven IMUs at trunk, head and upper extremities. They performed a predefined course of box handling for 40 min at different motion speeds and ranges of motion. The orientation estimation was compared to an optical motion tracking system. The resulting mean root mean squared error (RMSE) of all measurements ranged from 1.7 deg to 7.6 deg (roll and pitch) and from 3.5 deg to 15.0 deg (heading) depending on the measured segment, at a mean interval-length of 1.1 min between two ZPs without magnetometer usage. The 95% limits of agreement (LOA) ranged in best case from −2.9 deg to 3.6 deg at the hip roll angle and in worst case from −19.3 deg to 18.9 deg at the forearm heading angle. This study demonstrates that combining ZPs and bidirectional computation can reduce orientation error of IMUs in environments with magnetic field distortion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107
Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C. (2007) · Applied Ergonomics · doi:10.1016/j.apergo.2006.12.006 · Cited by 102
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Rouhani, H., Favre, J., Crevoisier, X., & Aminian, K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006674 · Cited by 72
Cited by
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329
Self-citationMusculoskeletal disorders as a fatigue failure process: evidence, implications and research needs
Gallagher, S., & Schall Jr., M. C. (2017) · Ergonomics · doi:10.1080/00140139.2016.1208848 · Cited by 160
“2015), the accuracy of these devices has been known to degrade when work activities involve complex, dynamic motions (Brodie, Walmsley, and Page 2008; Godwin, Agnew, and Stevenson 2009) or when measurements are taken in the presence of magnetically distorted fields (Schiefer et al. 2014).”
BackgroundBouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133
“However, the orientation around the vertical axis remains inaccurate [11,19].”
BackgroundSchiefer, C., Kraus, T., Ellegast, R. P., & Ochsmann, E. (2015) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-015-0058-5 · Cited by 31
“To support the RoM examination in functional diagnostics, we adapted an IMU based measuring system (CUELA [17,21]) to a functional diagnostics tool.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Schiefer, C., Ellegast, R. P., Hermanns, I., Kraus, T., Ochsmann, E., Larue, C., & Plamondon, A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2014-11-03
- Volume
- 136
- Issue
- 12
- Pages
- 121008-121008
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2002560787
- Cited by
- 35
- References
- 5
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of Inertial Sensor-Based Motion Capturing for Magnetically Distorted Field Applications. https://app.cochat.ai/papers/10.1115/1.4028822
- The paper
- Schiefer, C., Ellegast, R. P., Hermanns, I., Kraus, T., Ochsmann, E., Larue, C., & Plamondon, A. (2014). Optimization of Inertial Sensor-Based Motion Capturing for Magnetically Distorted Field Applications. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4028822
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.