Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Open accessAbstract
Ambulatory assessment of trunk posture is important in improving our understanding of the risk of low back injury. Recently, small inertial sensors combining accelerometers, gyroscopes and magnetometers were developed and appear to be promising for measuring human movement. However, the validity of such sensors for assessing three-dimensional (3D) trunk posture in motion has not been documented. The purpose of this study was to evaluate a hybrid system (HS) composed of two inertial sensors for the 3D measurement of trunk posture. A secondary purpose was to explore the utility of adding another source of information, a potentiometer, to measure the relative rotation between both sensors in order to improve the validity of the system. The first sensor was placed over the sacrum and the second on the upper part of the thorax. Both sensors were linked by a flexible rod with a potentiometer. A complementary quaternion filter algorithm was used to estimate trunk orientation by taking advantage of the nine components of each sensor and the potentiometer. The HS's orientations were compared to those obtained from a 3D optoelectronic system. Validation of the HS was performed in three steps in which six subjects had to perform manual handling tasks in: (1) static postures; (2) dynamic motions of short duration (30s); and (3) dynamic motions of long duration (30min). The results showed that the root mean square (RMS) error of the HS was generally below 3 degrees for the flexion and lateral bending axes, and less than 6 degrees for the torsion axis, and that this error was lower for the short-duration tests compared to the long-duration one. The potentiometer proved to be an essential addition, particularly when the magnetometer signals were corrupted and only the gyroscope and accelerometer could be combined. It is concluded that the HS can be a useful tool for quantifying 3D trunk posture in motion.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pelvis RMSE and correlation coefficients varied from 0.4 to 8.8° and 0.84 to 1.00, showing good to excellent validity.
“RMSE and correlation coefficients varied respectively from 0.4 to 8.8° and 0.84 to 1.00, showing good to excellent validity [30,36,38,41,42,52].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [36]
Trunk validity was similar across all movement planes and axes.
“Validity was similar across all movement planes and axes [34,36,37,38,41,46,47,48,49,50,51].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [36]
Cites
Grood, E. S., & Suntay, W. J. (1983) · Journal of Biomechanical Engineering · doi:10.1115/1.3138397 · Cited by 3,823 · see citing works
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 890 · see citing works
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655 · see citing works
Positive and negative evidence of risk factors for back disorders
Burdorf, A., & Sorock, G. S. (1997) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.217 · Cited by 641 · see citing works
Biomechanical risk factors for occupationally related low back disorders
Marras, W. S., Lavender, S. A., LEURGANS, S. E., Fathallah, F. A., Ferguson, S., Allread, W. G., & RAJULU, S. L. (1995) · Ergonomics · doi:10.1080/00140139508925111 · Cited by 616 · see citing works
Roetenberg, D., Luinge, H. J., Baten, C. T. M., & Veltink, P. H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847353 · Cited by 588 · see citing works
Physical load during work and leisure time as risk factors for back pain
Hoogendoorn, W. E., van Poppel, M. N. M., Bongers, P. M., Koes, B. W., & Bouter, L. M. (1999) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.451 · Cited by 564 · see citing works
Li, G., & Buckle, P. (1999) · Ergonomics · doi:10.1080/001401399185388 · Cited by 558 · see citing works
Flexion and Rotation of the Trunk and Lifting at Work Are Risk Factors for Low Back Pain
Hoogendoorn, W. E., Bongers, P. M., de Vet, H. C. W., Douwes, M., Koes, B. W., Miedema, M. C., Ariëns, G. A., & Bouter, L. M. (2000) · Spine · doi:10.1097/00007632-200012010-00018 · Cited by 550 · see citing works
Esola, M. A., McClure, P. W., Fitzgerald, G. K., & Siegler, S. (1996) · Spine · doi:10.1097/00007632-199601010-00017 · Cited by 464 · see citing works
Biomechanical risk factors for occupationally related low back disorders
(1996) · Journal of Safety Research · doi:10.1016/s0022-4375(97)81191-7 · Cited by 454 · see citing works
Marras, W. S., Fathallah, F. A., Miller, R. J., Davis, S. W., & Mirka, G. A. (1992) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(92)90078-e · Cited by 273 · see citing works
Kilbom, Å. (1994) · PubMed · Cited by 225 · see citing works
Quantifying variation in physical load using exposure-vs-time data
Mathiassen, S. E., & Winkel, J. (1991) · Ergonomics · doi:10.1080/00140139108964889 · Cited by 204 · see citing works
Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185 · see citing works
A new technique for determining 3-D joint angles: the tilt/twist method
Crawford, N. R., Yamaguchi, G. T., & Dickman, C. A. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00080-1 · Cited by 175 · see citing works
Bachmann, E. R. (2000) · Cited by 140 · see citing works
Reliability in evidence-based clinical practice: a primer for allied health professionals☆
Batterham, A. M., & George, K. (2003) · Physical Therapy in Sport · doi:10.1016/s1466-853x(03)00076-2 · Cited by 139 · see citing works
Miniature six-DOF inertial system for tracking HMDs
Foxlin, E. M., Harrington, M., & Altshuler, Y. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.317434 · Cited by 112 · see citing works
Estimating orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7612 · Cited by 103 · see citing works
A real-time gyroscopic system for three-dimensional measurement of lumbar spine motion
Lee, R., Laprade, J., & Fung, E. H. K. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00115-2 · Cited by 99 · see citing works
Veltink, P. H., Slycke, P. J., Hemssems, J., Buschman, R., Bultstra, G., & Hermens, H. J. (2002) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00041-3 · Cited by 99 · see citing works
Quantitative electromyographic evaluation of muscular load during work.
Jonsson, B. G. (1978) · PubMed · Cited by 75 · see citing works
Inertial sensing in ambulatory back load estimation
Baten, C. T. M., Oosterhoff, P., Kingma, I., Veltink, P. H., & Hermens, H. J. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.651834 · Cited by 18 · see citing works
Veltink, P. H., Luinge, H. J., Kooi, B. J., Baten, C. T. M., Slycke, P. J., Olthuis, W., & Bergveld, P. (2001) · University of Twente Research Information · Cited by 11 · see citing works
Ambulatory Low Back Load Exposure Estimation
Baten, C. T. M. (2000) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120004402855 · Cited by 10 · see citing works
Plamondon, A., Delisle, A., Larue, C., Desjardins, P., McFadden, D., Larivière, C., Gagnon, D., & Imbeau, D. (2005) · doi:10.70010/fsfc5324 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369 · see citing works
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329 · see citing works
Self-citationFiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 319 · see citing works
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Wearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263 · see citing works
Recent developments in fibre optic shape sensing
Amanzadeh, M., Aminossadati, S. M., Kizil, M. S., & Rakić, A. D. (2018) · Measurement · doi:10.1016/j.measurement.2018.06.034 · Cited by 196 · see citing works
Kim, S., & Nussbaum, M. A. (2012) · Ergonomics · doi:10.1080/00140139.2012.742932 · Cited by 151 · see citing works
Bouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133 · see citing works
The role of wearables in spinal posture analysis: a systematic review
Simpson, L. D., Maharaj, M. M., & Mobbs, R. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2430-6 · Cited by 115 · see citing works
Leardini, A., Lullini, G., Giannini, S., Berti, L., Ortolani, M., & Caravaggi, P. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-136 · Cited by 110 · see citing works
Beisenova, A., Issatayeva, A., Iordachita, I. I., Blanc, W., Molardi, C., & Tosi, D. (2019) · Optics Express · doi:10.1364/oe.27.022074 · Cited by 100 · see citing works
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96 · see citing works
Faber, G. S., Chang, C.-C., Kingma, I., Dennerlein, J. T., & van Dieën, J. H. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.042 · Cited by 88 · see citing works
Effect of local magnetic field disturbances on inertial measurement units accuracy
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.04.011 · Cited by 77 · see citing works
Emerging Trends of Body-Mounted Sensors in Sports and Human Gait Analysis
Gouwanda, D., & Senanayake, S. M. N. A. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69139-6_178 · Cited by 71 · see citing works
Voinea, G.-D., Butnariu, S., & Mogan, G. L. (2016) · Sensors · doi:10.3390/s17010003 · Cited by 69 · see citing works
Validation of a low-cost inertial motion capture system for whole-body motion analysis
Robert‐Lachaine, X., Mecheri, H., Muller, A., Larue, C., & Plamondon, A. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109520 · Cited by 69 · see citing works
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65 · see citing works
A novel method for assessing the 3-D orientation accuracy of inertial/magnetic sensors
Faber, G. S., Chang, C.-C., Rizun, P., & Dennerlein, J. T. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.029 · Cited by 56 · see citing works
A practical guidance for assessments of sedentary behavior at work: A PEROSH initiative
Holtermann, A., Schellewald, V., Mathiassen, S. E., Gupta, N., Pinder, A., Punakallio, A., Veiersted, K. B., Weber, B., Takala, E., Draicchio, F., et al. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.03.012 · Cited by 52 · see citing works
Paramedics on the job: Dynamic trunk motion assessment at the workplace
Prairie, J., & Corbeil, P. (2013) · Applied Ergonomics · doi:10.1016/j.apergo.2013.11.006 · Cited by 51 · see citing works
Brouwer, N. P., Yeung, T., Bobbert, M. F., & Besier, T. F. (2020) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13851 · Cited by 51 · see citing works
Schall, M. C., Fethke, N. B., Chen, H., & Gerr, F. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2014.12.005 · Cited by 48 · see citing works
Validation of the Flexible Electrogoniometer for Measuring Thoracic Kyphosis
Perriman, D. M., Scarvell, J. M., Hughes, A. R., Ashman, B., Lueck, C. J., & Smith, P. N. (2010) · Spine · doi:10.1097/brs.0b013e3181d13039 · Cited by 48 · see citing works
Ranavolo, A., Don, R., Draicchio, F., Bartolo, M., Serrao, M., Padua, L., Cipolla, G., Pierelli, F., Iavicoli, S., & Sandrini, G. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2012.07.004 · Cited by 45 · see citing works
Workload Assessment in Field Using the Ambulatory CUELA System
Ellegast, R. P., Hermanns, I., & Schiefer, C. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02809-0_24 · Cited by 45 · see citing works
Nimbarte, A. D., Sun, Y., Jaridi, M., & Hsiao, H. (2013) · Applied Ergonomics · doi:10.1016/j.apergo.2013.02.008 · Cited by 44 · see citing works
Accuracy of angular displacements and velocities from inertial-based inclinometers
Chen, H., Schall, M. C., & Fethke, N. B. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.09.007 · Cited by 41 · see citing works
Kim, S., & Nussbaum, M. A. (2014) · Ergonomics · doi:10.1080/00140139.2014.907450 · Cited by 39 · see citing works
Chen, H., Schall, M. C., & Fethke, N. B. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2020.103187 · Cited by 38 · see citing works
Design and validation of an ambulatory inertial system for 3-D measurements of low back movements
Charry, E., Umer, M., & Taylor, S. B. (2011) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2011.6146618 · Cited by 37 · see citing works
Cerfoglio, S., Capodaglio, P., Rossi, P., Conforti, I., D’Angeli, V., Milani, E., Galli, M., & Cimolin, V. (2023) · Sensors · doi:10.3390/s23136156 · Cited by 37 · see citing works
Optimization of Inertial Sensor-Based Motion Capturing for Magnetically Distorted Field Applications
Schiefer, C., Ellegast, R. P., Hermanns, I., Kraus, T., Ochsmann, E., Larue, C., & Plamondon, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028822 · Cited by 35 · see citing works
WAGENAAR, R. C., Sapir, I., Zhang, Y., Markovic, S., Vaina, L. M., & Little, T. D. C. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091200 · Cited by 34 · see citing works
Koopman, A. S., Kingma, I., Faber, G. S., Bornmann, J., & van Dieën, J. H. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.10.001 · Cited by 34 · see citing works
Effect of mobility devices on orientation sensors that contain magnetometers
Kendell, C., & Lemaire, E. D. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.09.0132 · Cited by 32 · see citing works
Biomechanical risk assessment during field loading of hydraulic stretchers into ambulances
Prairie, J., Plamondon, A., Hegg-Deloye, S., Larouche, D., & Corbeil, P. (2015) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2015.11.014 · Cited by 29 · see citing works
Posture and lifting exposures for daycare workers
Labaj, A., Diesbourg, T. L., Dumas, G. A., Plamondon, A., Mercheri, H., & Larue, C. (2016) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2016.05.003 · Cited by 29 · see citing works
Paramedics' working strategies while loading a stretcher into an ambulance
Prairie, J., Plamondon, A., Larouche, D., Hegg-Deloye, S., & Corbeil, P. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.06.005 · Cited by 21 · see citing works
Lumbar posture assessment with fabric strain sensors
Vu, L. Q., Kim, K. H., Schulze, L. J. H., & Rajulu, S. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103624 · Cited by 20 · see citing works
Quebec Research on Work-related Musculoskeletal Disorders
Côté, J. N., Ngomo, S., Stock, S. R., Messing, K., Vézina, N., Antle, D. M., Delisle, A., Bellemare, M., Laberge, M., & St-Vincent, M. (2014) · Relations industrielles · doi:10.7202/1023009ar · Cited by 20 · see citing works
Robert‐Lachaine, X., Larue, C., Denis, D., Delisle, A., Mecheri, H., Corbeil, P., & Plamondon, A. (2019) · Ergonomics · doi:10.1080/00140139.2019.1612941 · Cited by 19 · see citing works
Novel printed body worn sensor for measuring the human movement orientation
Esfahani, M. I. M., Taghinezhad, S., Mottaghitalab, V., Narimani, R., & Parnianpour, M. (2016) · Sensor Review · doi:10.1108/sr-08-2015-0147 · Cited by 19 · see citing works
Evaluation of Eight Methods for Aligning Orientation of Two Coordinate Systems
Mecheri, H., Robert‐Lachaine, X., Larue, C., & Plamondon, A. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4033719 · Cited by 18 · see citing works
Burford, E.-M., Ellegast, R. P., Weber, B., Brehmen, M., Groneberg, D. A., Sinn-Behrendt, A., & Bruder, R. (2017) · Ergonomics · doi:10.1080/00140139.2017.1340673 · Cited by 18 · see citing works
Autonomous Quality Control of Joint Orientation Measured with Inertial Sensors
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2016) · Sensors · doi:10.3390/s16071037 · Cited by 17 · see citing works
Development of a Wearable IMU System for Automatically Assessing Lifting Risk Factors
Lu, M., Barim, M. S., Feng, S., Hughes, G., Hayden, M. A., & Werren, D. M. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-49904-4_15 · Cited by 15 · see citing works
Three-dimensional lower limb kinematic and kinetic analysis based on a wireless sensor system
Liu, T., Inoue, Y., SHIBATA, K., & Shiojima, K. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979856 · Cited by 16 · see citing works
Akbari, A., Thomas, X., & Jafari, R. (2017) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2017.7936036 · Cited by 13 · see citing works
O’Reilly, C., & Réjean Plamondon, B. (2010) · Behavior Research Methods · doi:10.3758/s13428-010-0030-3 · Cited by 13 · see citing works
Inter- and intra-tester reliability when measuring seated spinal postures with inertial sensors
Stenlund, T. C., Öhberg, F., Lundström, R., Lindroos, O., Häger, C. K., & Rehn, B. (2014) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2014.06.002 · Cited by 13 · see citing works
Cluster-based exposure variation analysis
Samani, A., Mathiassen, S. E., & Madeleine, P. (2013) · BMC Medical Research Methodology · doi:10.1186/1471-2288-13-54 · Cited by 13 · see citing works
Methods of Assessing Sedentary Behaviour
Marconcin, P., Júdice, P. B., Ferrari, G., Werneck, A. O., & Marques, A. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.99567 · Cited by 12 · see citing works
Sharif-Human movement instrumentation system (SHARIF-HMIS): Development and validation
Esfahani, M. I. M., Akbari, A., Zobeiri, O. A., Rashedi, E., & Parnianpour, M. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.07.008 · Cited by 12 · see citing works
Larouche, D., Bellemare, M., Prairie, J., Hegg-Deloye, S., & Corbeil, P. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.08.029 · Cited by 12 · see citing works
Driel, R. V., Trask, C., Johnson, P. W., Callaghan, J. P., Koehoorn, M. W., & Teschke, K. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.757479 · Cited by 12 · see citing works
Comparison of lifting and bending demands of the various tasks performed by daycare workers
Labaj, A., Diesbourg, T. L., Dumas, G. A., Plamondon, A., & Mecheri, H. (2018) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2018.11.001 · Cited by 12 · see citing works
Francés, L., Camo, P. M., Rodríguez-Ferradas, M. I., & Cazón, A. (2019) · Sensors · doi:10.3390/s19020296 · Cited by 11 · see citing works
Liu, K., INOUE, Y., & SHIBATA, K. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.522184 · Cited by 11 · see citing works
Validation of Pelvis and Trunk Range of Motion as Assessed Using Inertial Measurement Units
Ali, F., Hogen, C. A., Miller, E. J., & Kaufman, K. R. (2024) · Bioengineering · doi:10.3390/bioengineering11070659 · Cited by 11 · see citing works
Lebel, K., Hamel, M., Duval, C., Nguyen, H., & Boissy, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.016 · Cited by 10 · see citing works
Segmental Sensor Weighting Accuracy Evaluation Method for Fiber Optic Shape Sensing
Yang, Z., Liu, S., Yang, T., Wu, G., Liang, Y., & Dong, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3318238 · Cited by 9 · see citing works
Schiefer, C., Kraus, T., Ochsmann, E., Hermanns, I., & Ellegast, R. P. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21799-9_22 · Cited by 8 · see citing works
Olsen, G. F., Brilliant, S. S., Primeaux, D., & Najarian, K. (2009) · ICME International Conference on Complex Medical Engineering (CME) · doi:10.1109/iccme.2009.4906675 · Cited by 8 · see citing works
Instrumented vest for postural reeducation
Carvalho, P., Queirós, S., Moreira, A. H. J., Brito, J. H., Veloso, F., Terroso, M., Rodrigues, N. F., & Vilaça, J. L. (2017) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah.2017.7939300 · Cited by 7 · see citing works
Marker-based motion capture for measuring joint kinematics in leg swing simulator
Yunardi, R. T., & Winarno, W. (2017) · International Conference on Instrumentation, Control, and Automation (ICA) · doi:10.1109/ica.2017.8068405 · Cited by 7 · see citing works
Sensor Fusion for Enhancing Motion Capture: Integrating Optical and Inertial Motion Capture Systems
Hicks, H. N., Chen, H., & Harper, S. A. (2025) · Sensors · doi:10.3390/s25154680 · Cited by 6 · see citing works
Posture study for self-training system of patient transfer
Huang, Z., Nagata, A., Kanai‐Pak, M., Maeda, J., Kitajima, Y., Nakamura, M., Aida, K., Kuwahara, N., Ogata, T., & Ota, J. (2012) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2012.6491073 · Cited by 6 · see citing works
Dufour, J. S., Aurand, A. M., Weston, E. B., Haritos, C. N., Souchereau, R. A., & Marras, W. S. (2021) · Journal of Applied Biomechanics · doi:10.1123/jab.2020-0213 · Cited by 7 · see citing works
Choi, S., & Lee, S.-Y. (2012) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2012.6227474 · Cited by 6 · see citing works
Harnett, K., Plint, B., Chan, K. Y., Clark, B., Netto, K., Davey, P. C., Müller, S., & Rosalie, S. M. (2022) · PeerJ · doi:10.7717/peerj.13228 · Cited by 7 · see citing works
Visual estimation of lower limb motion using physical and virtual sensors
Liu, K., Liu, T., SHIBATA, K., & INOUE, Y. (2010) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2010.5512355 · Cited by 6 · see citing works
Liu, K., INOUE, Y., & SHIBATA, K. (2010) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.5.472 · Cited by 5 · see citing works
Cuesta‐Vargas, A., & William, J. (2011) · Fisioterapia · doi:10.1016/j.ft.2010.12.005 · Cited by 5 · see citing works
Schall, M. C., Fethke, N., Thomas, G. W., Gerr, F., Wilder, D. G., & Pennathur, P. (2014) · doi:10.17077/etd.orlp9g1i · Cited by 5 · see citing works
Samani, A., & Madeleine, P. (2013) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2013.12.001 · Cited by 4 · see citing works
Leijendekkers, R. A., Hoogeboom, T. J., van Hinte, G., Didden, L., Anijs, T., der Sanden, M. W. G. N., & Verdonschot, N. J. J. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217046 · Cited by 3 · see citing works
Design and Optimization of a Wearable Underactuated Mechanism for Spinal Posture Measurement
Hsu, M., Chen, H., Soong, C., & Yeh, T. ‐. (2024) · Journal of Mechanisms and Robotics · doi:10.1115/1.4065075 · Cited by 3 · see citing works
A Comparison of Sensor Placement for Estimating Trunk Postures in Manual Material Handling
Hischke, M., Arroyo, G., Reiser, R. F., & Rosecrance, J. C. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-96089-0_9 · Cited by 3 · see citing works
GLOBAL BIOMECHANICAL EVALUATION DURING WORK AND DAILY-LIFE ACTIVITIES
Draicchio, F., Silvetti, A., Amici, F., Iavicoli, S., Ranavolo, A., Muscillo, R., Schmid, M., Tommaso, D., Sandrini, G., Bartolo, M., et al. (2010) · International Conference on Biomedical Electronics and Devices · doi:10.5220/0002740901080112 · Cited by 3 · see citing works
Implementation of motion capture system for trajectory planning of leg swing simulator
Yunardi, R. T., Firdaus, A. A., Agustin, E. I., & Pujiyanto, P. (2017) · International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM) · doi:10.1109/issimm.2017.8124252 · Cited by 3 · see citing works
Posture and Lifting Exposure of Daycare Workers: A Pilot Field Study
Labaj, A. (2014) · QSpace (Queen's University Library) · Cited by 3 · see citing works
Quantifizierung physischer Belastungen am Arbeitsplatz
Ellegast, R. P. (2010) · Zentralblatt für Arbeitsmedizin Arbeitsschutz und Ergonomie · doi:10.1007/bf03344322 · Cited by 2 · see citing works
Igwesi-Chidobe, C. N., Anih, E. U., Emmanuel, G. N., & Ozumba, B. C. (2025) · F1000Research · doi:10.12688/f1000research.160172.2 · Cited by 1 · see citing works
Brusaca, L. A., Barbieri, D. F., Holtermann, A., Gupta, N., & Mathiassen, S. E. (2025) · IISE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/24725838.2025.2573776 · Cited by 1 · see citing works
Fiber optic measurement system for determination of extended object position and bends in 3D space
Egorova, D. A., Kulikov, A. V., Mukhtubaev, A. B., & Plotnikov, M. Y. (2020) · Scientific and technical journal of information technologies mechanics and optics · doi:10.17586/2226-1494-2020-20-3-346-352 · Cited by 1 · see citing works
A novel cost-effective postural tracking algorithm using marker-based video processing
Nazerian, R., Korhan, O., & Shakeri, E. (2021) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2021.1941650 · Cited by 1 · see citing works
Torso Motion Monitoring with an IMU Set-Up
Sgrosso, M., Ceccarelli, M., Russo, M., Garrosa, M., & Cafolla, D. (2023) · Mechanisms and machine science · doi:10.1007/978-3-031-29815-8_7 · Cited by 1 · see citing works
Optical Multicore Fiber Shape Sensors. A numerical and experimental performance assessment.
Floris, I. (2020) · doi:10.4995/thesis/10251/148715 · Cited by 1 · see citing works
De Beer, N., Christelis, L., & Af, V. D. M. (2012) · SUNScholar (Stellenbosch University)
Scanning and motion capturing of vertebral kinematics
Christelis, L. (2008) · SUNScholar (Stellenbosch University)
Examining the role of sitting behaviour in non-specific chronic low back pain
O’Sullivan, K. (2012) · Arrow@dit (Dublin Institute of Technology)
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2016) · International Conference on Digital Health · doi:10.1145/2896338.2896361
A Systematic Review on Lumbar Alignment Device’s Mechanism Using Sensor Fusion Technology
Christhudass, A. J., Manimegalai, P., Leo, A., Pillai, K. K., & Helina, S. T. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1937/1/012003
Evaluating the use of inertial measurement unit technology during an ice hockey shooting task
Denroche, S. K. (2020) · eScholarship@McGill (McGill) · doi:10.82308/1578
INERTIAL SENSOR-BASED MOTION ANALYSIS SYSTEM OF BRIDGE-STYLE MOVEMENT FOR REHABILITATION TREATMENTS
Zhang, G., Wang, C., Long, J., Liu, Q., Wei, J., Duan, L., Luo, C., Zhang, X., Wang, Y., Wang, G., et al. (2021) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519421500664
Hsu, M., Chen, H., & Yeh, T. ‐. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3602573
Iizuka, M., Wilkie, E. W. C., Denroche, S. K., Renaud, P. J., Pearsall, D. J., & Robbins, S. M. K. (2026) · Sports Engineering · doi:10.1007/s12283-025-00534-3
- Authors
- Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C.
- Affiliations
- Institut de recherche Robert-Sauvé en santé et en sécurité du travail (CA)
- Corresponding author
- Plamondon, A.
- Venue
- Applied Ergonomics
- Publisher
- Elsevier BV
- Published
- 2007-11
- Volume
- 38
- Issue
- 6
- Pages
- 697-712
- ISSN
- 0003-6870 (ISSN-L)
- OpenAlex
- W2074799303
- Cited by
- 102
- References
- 27
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 8 · 2019: 7 · 2018: 5 · 2017: 12 · 2016: 8 · 2015: 5 · 2014: 7 · 2013: 5 · 2012: 8
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- green
- pharesst.irsst.qc.ca
- Locations
- Applied Ergonomics (publishedVersion)
- PubMed (publishedVersion)
- PhareSST (submittedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Social Psychology › Ergonomics and Musculoskeletal Disorders
- Keywords
- trunk posture, inertial sensors, accelerometer, gyroscope, magnetometer, potentiometer, low back injury risk, manual material handling, sensor fusion, measurement validity
- MeSH terms
- Adult, Data Display, Humans, Male, Movement, Posture, Quebec, Thorax, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review