Conformability of a Thin Elastic Membrane Laminated on a Soft Substrate With Slightly Wavy Surface
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
When laminating a thin elastic membrane on a substrate with surface roughness, three scenarios can happen: fully conformed (FC), i.e., the membrane completely follows the surface morphology of the substrate without any interfacial gap, nonconformed (NC), i.e., the membrane remains flat if gravity is not concerned, and partially conformed (PC). Good conformability can enhance effective membrane-to-substrate adhesion strength and can facilitate signal/heat/mass transfer across the interface, which are of great importance to soft electronics laminated on rough bio-tissues. To reveal governing parameters in this problem and to predict conformability, energy minimization is implemented after successfully finding the substrate elastic energy under partially conformable contact. Four dimensionless governing parameters involving the substrate roughness, membrane thickness, membrane and substrate elastic moduli, and membrane-to-substrate intrinsic work of adhesion have been identified to analytically predict the conformability status and the area of contact. The analytical prediction has found excellent agreement with experimental observations. In summary, an experimentally validated quantitative guideline for the conformability of elastic membrane on soft corrugated substrate has been established in the four-parameter design space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Ultrastrong adhesion of graphene membranes
Koenig, S. P., Boddeti, N. G., Dunn, M. L., & Bunch, J. S. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.123 · Cited by 1,107 · cited 3×
“Moreover, conformability-based metrology has been applied to estimate the adhesion strength between FLG and a precorrugated polydimethylsiloxane [7].”
BackgroundFlexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749 · cited 1×
“In addition to adhesion strength, conformability of thin membranes on rough surfaces also plays a significant role in the functionality of bio-integrated electronics [8], which have sprung up in recent years due to unlimited potentials in disease monitoring, diagnosis, treatment, as well as human–machine interfaces.”
BackgroundSelf-citationIn vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Self-citationChoi, S., Park, J., Hyun, W., Kim, J., Kim, J., Lee, Y. B., Song, C., Hwang, H. J., Kim, J. H., Hyeon, T., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b02790 · Cited by 568 · cited 1×
“As another example, wearable heaters for thermoregulation and thermal treatment [17,18] require uniform and efficient heat transfer at the heater–tissue interface, which fully relies on intimate heater–tissue contact.”
Background“Cut‐and‐Paste” Manufacture of Multiparametric Epidermal Sensor Systems
Yang, S., Chen, Y., Nicolini, L., Pasupathy, P., Sacks, J., Su, B., Yang, R., Sanchez, D., Chang, Y., Wang, P., et al. (2015) · Advanced Materials · doi:10.1002/adma.201502386 · Cited by 304
Self-citationCapacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288
Cited by
Strain Engineering of 2D Materials: Issues and Opportunities at the Interface
Dai, Z., Liu, L., & Zhang, Z. (2019) · Advanced Materials · doi:10.1002/adma.201805417 · Cited by 802
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Self-citationStrategies for body-conformable electronics
Liu, S., Rao, Y., Jang, H., Tan, P., & Lu, N. (2022) · Matter · doi:10.1016/j.matt.2022.02.006 · Cited by 306
Self-citationLuo, N., Huang, Y., Liu, J., Chen, S., Wong, C. P., & Zhao, N. (2017) · Advanced Materials · doi:10.1002/adma.201702675 · Cited by 275
Low-cost, μm-thick, tape-free electronic tattoo sensors with minimized motion and sweat artifacts
Wang, Y., Qiu, Y., Ameri, S. K., Jang, H., Dai, Z., Huang, Y., & Lu, N. (2018) · npj Flexible Electronics · doi:10.1038/s41528-017-0019-4 · Cited by 192
Self-citation
Metadata
- Authors
- Wang, L., & Lu, N.
- Venue
- Journal of Applied Mechanics
- Publisher
- ASME International
- Published
- 2016-01-27
- Volume
- 83
- Issue
- 4
- ISSN
- 0021-8936 (ISSN-L)
- 1528-9036
- OpenAlex
- W2239376896
- Cited by
- 81
- References
- 9
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.