A Thin Elastic Membrane Conformed to a Soft and Rough Substrate Subjected to Stretching/Compression
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Conformability of bio-integrated electronics to soft and microscopically rough biotissues can enhance effective electronics–tissue interface adhesion and can facilitate signal/heat/mass transfer across the interface. When biotissues deform, for example, when skin stretches or heart beats, the deformation may lead to changes in conformability. Although a theory concerning just full conformability (FC) under deformation has been developed (i.e., the FC theory), there is no available theory for partially conformable (PC) systems subjected to deformation. Taking advantage of the path-independent feature of elastic deformation, we find that the total energy of a PC system subjected to stretching or compression can be analytically expressed and minimized. We discover that the FC theory is not sufficient in predicting FC and a full energy landscape obtained by our PC theory is needed for searching for the equilibrium. Our results reveal that stretching enhances conformability while compression degrades it. In addition to predicting the critical parameters to maintain FC under deformation, our PC theory can also be applied to predict the critical compressive strain beyond which FC is lost. Our theory has been validated by laminating poly(methyl methacrylate) (PMMA) membranes of different thicknesses on human skin and inducing skin deformation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749 · cited 1×
“In recent years, soft bio-integrated electronics have gathered growing attention due to their unlimited potential in disease monitoring, diagnosis, and treatment, as well as in human–machine interaction [1,2].”
BackgroundSelf-citationIn vivo measurements of the elastic mechanical properties of human skin by indentation tests
Pailler-Mattei, C., Bec, S., & Zahouani, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.011 · Cited by 724
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669 · cited 3×
“Parameters are chosen to be h0 20 lm, k0 150 lm [27], Es 130 kPa [28], Em 3:3 GPa [30,31], andc 18 mJ/m2 [32].”
Self-citationXu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Self-citation“Cut‐and‐Paste” Manufacture of Multiparametric Epidermal Sensor Systems
Yang, S., Chen, Y., Nicolini, L., Pasupathy, P., Sacks, J., Su, B., Yang, R., Sanchez, D., Chang, Y., Wang, P., et al. (2015) · Advanced Materials · doi:10.1002/adma.201502386 · Cited by 304
Self-citationCapacitive Epidermal Electronics for Electrically Safe, Long‐Term Electrophysiological Measurements
Jeong, J., Kim, M. K., Cheng, H., Yeo, W., Huang, X., Liu, Y., Zhang, Y., Huang, Y., & Rogers, J. A. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300334 · Cited by 288 · cited 1×
“In addition to extensive research on the devices, bioelectronics interface is also an interesting topic [15–18] because people have realized that intimate and secure contact between the thin film device and the bio-tissue is of great importance to the sensitivity and signal-to-noise ratio of both in vivo [19,20] and e…”
Background
Cited by
Strain Engineering of 2D Materials: Issues and Opportunities at the Interface
Dai, Z., Liu, L., & Zhang, Z. (2019) · Advanced Materials · doi:10.1002/adma.201805417 · Cited by 802
Wang, X., Liu, Q., Wu, S., Xu, B., & Xu, H. (2019) · Advanced Materials · doi:10.1002/adma.201807716 · Cited by 531
Strategies for body-conformable electronics
Liu, S., Rao, Y., Jang, H., Tan, P., & Lu, N. (2022) · Matter · doi:10.1016/j.matt.2022.02.006 · Cited by 306
Self-citationLow-cost, μm-thick, tape-free electronic tattoo sensors with minimized motion and sweat artifacts
Wang, Y., Qiu, Y., Ameri, S. K., Jang, H., Dai, Z., Huang, Y., & Lu, N. (2018) · npj Flexible Electronics · doi:10.1038/s41528-017-0019-4 · Cited by 192
Self-citationImperceptible electrooculography graphene sensor system for human–robot interface
Ameri, S. K., Kim, M., Kuang, I. A., Perera, W. K., Alshiekh, M., Jeong, H., Topcu, U., Akinwande, D., & Lu, N. (2018) · npj 2D Materials and Applications · doi:10.1038/s41699-018-0064-4 · Cited by 162
Self-citation
Metadata
- Authors
- Wang, L., Qiao, S., Kabiri Ameri, S., Jeong, H., & Lu, N.
- Venue
- Journal of Applied Mechanics
- Publisher
- ASME International
- Published
- 2017-09-12
- Volume
- 84
- Issue
- 11
- ISSN
- 0021-8936 (ISSN-L)
- 1528-9036
- OpenAlex
- W2749253573
- Cited by
- 42
- References
- 7
- FWCI
- 3.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.