The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Active Tremor Estimation and Suppression in Human Elbow Joint
Abstract
A new control algorithm was developed for tremor estimation and suppression in a second order linear model of the human elbow joint. An adaptive method developed to estimate a simple harmonic disturbance was generalized for tremorous motion with spectral composition similar to the clinical reports for action tremor. Numerical simulations showed the ability of proposed controller to reduce tremor amplitude without generating significant resistance against voluntary motion of the arm. The designed algorithm can be used in an upper-limb orthosis to suppress debilitating tremorous motion of the arm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The transfer function associated with Figure 4 can be expressed as a second-order system similar to that provided in Pledgie et al. (2000), Rocon and Belda-Lois (2004), and Taheri et al. (2011), with the addition of a differentiator to obtain a velocity output.”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Taheri et al. (2011)
Citations
Cites
Adaptive algorithms for the rejection of sinusoidal disturbances with unknown frequency
Bodson, M., & Douglas, S. C. (1997) · Automatica · doi:10.1016/s0005-1098(97)00149-0 · Cited by 522
Gomi, H., & Osu, R. (1998) · Journal of Neuroscience · doi:10.1523/jneurosci.18-21-08965.1998 · Cited by 356
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
A model of force and impedance in human arm movements
Tee, K. P., Burdet, E., Chew, C., & Milner, T. E. (2004) · Biological Cybernetics · doi:10.1007/s00422-004-0484-4 · Cited by 164
Hamel, W., Herzog, J., Kopper, F., Pinsker, M., Weinert, D., Müller, D., Krack, P., Deuschl, G., & Mehdorn, H. (2007) · Acta Neurochirurgica · doi:10.1007/s00701-007-1230-1 · Cited by 151
Velasco, F., Jiménez, F., Pérez, M. L., Carrillo-Ruiz, J. D., Velasco, A. L., Ceballos, J., & Velasco, M. (2001) · Neurosurgery · doi:10.1097/00006123-200108000-00009 · Cited by 126
Miwa, H. (2006) · The Cerebellum · doi:10.1080/14734220601016080 · Cited by 104
(1998) · PubMed · Cited by 101
Tremor suppression through impedance control
Pledgie, S., Barner, K. E., Agrawal, S. K., & Rahman, T. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830949 · Cited by 85
Kuncel, A. M., Cooper, S. E., Wolgamuth, B. R., & Grill, W. M. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.897004 · Cited by 73
Loureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70
Tuned vibration absorber for suppression of rest tremor in Parkinson’s disease
Hashemi, S. M., Golnaraghi, M. F., & Patla, A. E. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351012 · Cited by 68
Mechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68
(1995) · PubMed · Cited by 63
Gillard, D. M., Cameron, T., Prochazka, A., & Gauthier, M. J. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788474 · Cited by 61
Xu, Y., & Hollerbach, J. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.752938 · Cited by 43
Multimodal BCI-mediated FES suppression of pathological tremor
Rocón, E., Gallego, J. Á., Barrios, L. J., Victoria, A. R., Ibáñez, J., Farina, D., Negro, F., Dideriksen, J. L., Conforto, S., D’Alessio, T., et al. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627914 · Cited by 42
Evaluation of a wearable orthosis and an associated algorithm for tremor suppression
Manto, M. U., Rocón, E., Pons, J. L., Lois, J. M. B., & Camut, S. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/007 · Cited by 41
Controllable mechanical tremor reduction. Assessment of two orthoses
Lois, J. M. B., Martinez-Reyero, A. I., Castillo, A., Rocón, E., Pons, J. L., Loureiro, R. C. V., Manto, M. U., Normie, L., & Soede, M. (2007) · Technology and Disability · doi:10.3233/tad-2007-19402 · Cited by 29
Tremorgenesis: a new conceptual scheme using reciprocally innervated circuit of neurons
Manto, M. (2008) · Journal of Translational Medicine · doi:10.1186/1479-5876-6-71 · Cited by 21
Reyes, K. D. L., Chandrasekhar, S. S., Tagliati, M., & Alterman, R. L. (2010) · Operative Neurosurgery · doi:10.1227/01.neu.0000369646.01287.42 · Cited by 12
Tremor suppression orthoses for parkinson’s patients: A frequency range perspective
Rahimi, F., Almeida, Q. J., Wang, D., & Janabi‐Sharifi, F. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332392 · Cited by 11
Cited by
Sorted by citations
Force and Stiffness Backstepping-Sliding Mode Controller for Pneumatic Cylinders
Taheri, B., Case, D., & Richer, E. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2294970 · Cited by 89
Self-citationMedical Devices for Tremor Suppression: Current Status and Future Directions
Mo, J., & Priefer, R. (2021) · Biosensors · doi:10.3390/bios11040099 · Cited by 71
Robust Controller for Tremor Suppression at Musculoskeletal Level in Human Wrist
Taheri, B., Case, D., & Richer, E. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2295034 · Cited by 63
Self-citationFromme, N. P., Camenzind, M., Riener, R., & Rossi, R. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0543-7 · Cited by 56
Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
Self-citation
Metadata
- Authors
- Taheri, B., Case, D., & Richer, E.
- Affiliations
- Southern Methodist University (US)
- ORCID
- Richer, Edmond
- Venue
- ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2
- Publisher
- ASMEDC
- Published
- 2011-01-01
- Pages
- 115-120
- ISSN
- 2151-1853 (ISSN-L)
- OpenAlex
- W1996658399
- Cited by
- 18
- References
- 22
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 3 · 2021: 2 · 2020: 1 · 2019: 4 · 2017: 1 · 2016: 1 · 2014: 3 · 2013: 1
- FWCI
- 2.37
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- ASME Dynamic Systems and Control Conference (DSCC) (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Physical Sciences › Engineering › Control and Systems Engineering › Adaptive Control of Nonlinear Systems
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- tremor suppression, elbow, action tremor, adaptive control, upper limb orthosis, voluntary movement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review