The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Orientation and characterization of immobilized antibodies for improved immunoassays (Review)
Open accessAbstract
Orientation of surface immobilized capture proteins, such as antibodies, plays a critical role in the performance of immunoassays. The sensitivity of immunodiagnostic procedures is dependent on presentation of the antibody, with optimum performance requiring the antigen binding sites be directed toward the solution phase. This review describes the most recent methods for oriented antibody immobilization and the characterization techniques employed for investigation of the antibody state. The introduction describes the importance of oriented antibodies for maximizing biosensor capabilities. Methods for improving antibody binding are discussed, including surface modification and design (with sections on surface treatments, three-dimensional substrates, self-assembled monolayers, and molecular imprinting), covalent attachment (including targeting amine, carboxyl, thiol and carbohydrates, as well as “click” chemistries), and (bio)affinity techniques (with sections on material binding peptides, biotin-streptavidin interaction, DNA directed immobilization, Protein A and G, Fc binding peptides, aptamers, and metal affinity). Characterization techniques for investigating antibody orientation are discussed, including x-ray photoelectron spectroscopy, spectroscopic ellipsometry, dual polarization interferometry, neutron reflectometry, atomic force microscopy, and time-of-flight secondary-ion mass spectrometry. Future perspectives and recommendations are offered in conclusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Isolation of pure IgG1, IgG2a and IgG2b immunoglobulins from mouse serum using protein A-Sepharose
Ey, P. L., Prowse, S. J., & Jenkin, C. R. (1978) · Immunochemistry · doi:10.1016/0161-5890(78)90070-6 · Cited by 2,685
Metal chelate affinity chromatography, a new approach to protein fractionation
PORATH, J., CARLSSON, J., OLSSON, I., & BELFRAGE, G. (1975) · Nature · doi:10.1038/258598a0 · Cited by 2,068
Plasma-surface modification of biomaterials
Chu, P. (2002) · Materials Science and Engineering: R: Reports · doi:10.1016/s0927-796x(02)00004-9 · Cited by 1,578
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Hochuli, E., Döbeli, H., & Schacher, A. (1987) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)93969-4 · Cited by 1,112
Polymer surface modification by plasmas and photons
Chan, C.-M., Ko, T.-M., & Hiraoka, H. (1996) · Surface Science Reports · doi:10.1016/0167-5729(96)80003-3 · Cited by 1,074
Hochuli, E., Bannwarth, W., Döbeli, H., Gentz, R., & Stüber, D. (1988) · Nature Biotechnology · doi:10.1038/nbt1188-1321 · Cited by 1,046
Siow, K. S., Britcher, L., Kumar, S., & Griesser, H. J. (2006) · Plasma Processes and Polymers · doi:10.1002/ppap.200600021 · Cited by 972
Awaja, F., Gilbert, M., Kelly, G., Fox, B., & Pigram, P. J. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.04.007 · Cited by 928
Self-citationPurification and some properties of streptococcal protein G, a novel IgG-binding reagent.
Björck, L., & Kronvall, G. (1984) · The Journal of Immunology · doi:10.4049/jimmunol.133.2.969 · Cited by 806
A synthetic IgG-binding domain based on staphylococcal protein A
Nilsson, B., Moks, T., Jansson, B., Abrahmsén, L., Elmblad, A., Holmgren, E., Henrichson, C., Jones, T. A., & Uhlén, M. (1987) · "Protein Engineering, Design and Selection" · doi:10.1093/protein/1.2.107 · Cited by 759
Protein Interactions with Polymer Coatings and Biomaterials
Wei, Q., Becherer, T., Angioletti‐Uberti, S., Dzubiella, J., Wischke, C., Neffe, A. T., Lendlein, A., Ballauff, M., & Haag, R. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201400546 · Cited by 743
Hernandez, K., & Fernandez-Lafuente, R. (2011) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2010.10.003 · Cited by 614
Optimizing antibody immobilization strategies for the construction of protein microarrays
Peluso, P., Wilson, D. S., Do, D., Tran, H., Venkatasubbaiah, M., Quincy, D., Heidecker, B., Poindexter, K., Tolani, N., Phelan, M., et al. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00442-6 · Cited by 520
Porath, J., & Olin, B. (1983) · Biochemistry · doi:10.1021/bi00276a015 · Cited by 510
Phage display: Concept, innovations, applications and future
Pande, J., Szewczyk, M. M., & Grover, A. K. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.07.004 · Cited by 492
Antibody orientation on biosensor surfaces: a minireview
Trilling, A. K., Beekwilder, J., & Zuilhof, H. (2013) · The Analyst · doi:10.1039/c2an36787d · Cited by 466
Kumar, S., Aaron, J., & Sokolov, K. (2008) · Nature Protocols · doi:10.1038/nprot.2008.1 · Cited by 411
Wagner, M. S., & Castner, D. G. (2001) · Langmuir · doi:10.1021/la001209t · Cited by 409
Lu, B., Smyth, M. R., & O'Kennedy, R. (1996) · The Analyst · doi:10.1039/an996210029r · Cited by 360
Gupta, R., & Chaudhury, N. K. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.12.025 · Cited by 349
Vashist, S. K., Lam, E., Hrapovic, S., Male, K. B., & Luong, J. H. T. (2014) · Chemical Reviews · doi:10.1021/cr5000943 · Cited by 345
Turková, J. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00434-4 · Cited by 318
Site-directed antibody immobilization techniques for immunosensors
Makaraviciute, A., & Ramanaviciene, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.060 · Cited by 316
Protein absorption and ellipsometry in biomaterial research
Elwing, H. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00112-9 · Cited by 298
Oriented immobilization of proteins on solid supports for use in biosensors and biochips: a review
Liu, Y., & Yu, J. (2016) · Microchimica Acta · doi:10.1007/s00604-015-1623-4 · Cited by 279
Solid supports for microarray immunoassays
Kusnezow, W., & Hoheisel, J. D. (2003) · Journal of Molecular Recognition · doi:10.1002/jmr.625 · Cited by 277
Recent advances in immobilization methods of antibodies on solid supports
Jung, Y., Jeong, J. Y., & Chung, B. H. (2008) · The Analyst · doi:10.1039/b800014j · Cited by 259
Solid Supports in Enzyme-Linked Immunosorbent Assay and Other Solid-Phase Immunoassays
Butler, J. E. (2000) · Methods · doi:10.1006/meth.2000.1031 · Cited by 257
Controlling Antibody Orientation on Charged Self-Assembled Monolayers
Chen, S., Liu, L., Zhou, J., & Jiang, S. (2003) · Langmuir · doi:10.1021/la026498v · Cited by 255
Protein and peptide arrays: Recent trends and new directions
Cretich, M., Damin, F., Pirri, G., & Chiari, M. (2006) · Biomolecular Engineering · doi:10.1016/j.bioeng.2006.02.001 · Cited by 248
Label‐free detection techniques for protein microarrays: Prospects, merits and challenges
Ray, S., Mehta, G., & Srivastava, S. (2010) · PROTEOMICS · doi:10.1002/pmic.200900458 · Cited by 224
Oriented Immobilization of Antibodies onto the Gold Surfaces via Their Native Thiol Groups
Karyakin, A. A., Presnova, G. V., Rubtsova, M. Y., & Egorov, A. M. (2000) · Analytical Chemistry · doi:10.1021/ac9907890 · Cited by 206
Butler, J. E., Ni, L., Brown, W. R., Joshi, K. S., Chang, J., Rosenberg, B., & Voss, E. W. (1993) · Molecular Immunology · doi:10.1016/0161-5890(93)90135-x · Cited by 188
Vashist, S. K., Dixit, C. K., MacCraith, B. D., & O'Kennedy, R. (2011) · The Analyst · doi:10.1039/c1an15325k · Cited by 179
Wacker, R., Schröder, H., & Niemeyer, C. M. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.03.017 · Cited by 171
Wang, H., Castner, D. G., Ratner, B. D., & Jiang, S. (2004) · Langmuir · doi:10.1021/la035376f · Cited by 163
Design of targeted lipid nanocapsules by conjugation of whole antibodies and antibody Fab’ fragments
Béduneau, A., Saulnier, P., Hindré, F., Clavreul, A., Leroux, J.-C., & Benoit, J.-P. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.05.014 · Cited by 161
Boozer, C., Ladd, J., Chen, S., Yu, Q., Homola, J., & Jiang, S. (2004) · Analytical Chemistry · doi:10.1021/ac048908l · Cited by 161
Bilek, M. M., & McKenzie, D. R. (2010) · Biophysical Reviews · doi:10.1007/s12551-010-0028-1 · Cited by 160
Polyarginine as a multifunctional fusion tag
Fuchs, S. M., & Raines, R. T. (2005) · Protein Science · doi:10.1110/ps.051393805 · Cited by 128
Sanni, O., Wagner, M. S., Briggs, D., Castner, D. G., & Vickerman, J. C. (2002) · Surface and Interface Analysis · doi:10.1002/sia.1438 · Cited by 117
Xu, H., Zhao, X., Grant, C. A., Lu, J. R., Williams, D. E., & Penfold, J. (2006) · Langmuir · doi:10.1021/la0532454 · Cited by 114
Xia, N., May, C. J., McArthur, S. L., & Castner, D. G. (2002) · Langmuir · doi:10.1021/la020022u · Cited by 112
Roeters, S. J., van Dijk, C. N., Torres‐Knoop, A., Backus, E. H. G., Campen, R. K., Bonn, M., & Woutersen, S. (2013) · The Journal of Physical Chemistry A · doi:10.1021/jp401159r · Cited by 101
Controlled antibody immobilization onto immunoanalytical platforms by synthetic peptide
Jung, Y., Kang, H. J., Lee, J. M., Jung, S. O., Yun, W. S., Chung, S. J., & Chung, B. H. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.10.022 · Cited by 100
Antibody nanosensors: a detailed review
Wujcik, E. K., Wei, H., Zhang, X., Guo, J., Yan, X., Sutrave, N., Wei, S., & Guo, Z. (2014) · RSC Advances · doi:10.1039/c4ra07119k · Cited by 100
SFG analysis of surface bound proteins: a route towards structure determination
Weidner, T., & Castner, D. G. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp50880c · Cited by 93
The Si‐tag for immobilizing proteins on a silica surface
Taniguchi, K., Nomura, K., Hata, Y., Nishimura, T., Asami, Y., & Kuroda, A. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.21208 · Cited by 93
LASIC: Light Activated Site-Specific Conjugation of Native IgGs
Hui, J. Z., Tamsen, S., Song, Y., & Tsourkas, A. (2015) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.5b00275 · Cited by 89
Half Antibody Fragments Improve Biosensor Sensitivity without Loss of Selectivity
Sharma, H., & Mutharasan, R. (2013) · Analytical Chemistry · doi:10.1021/ac3035426 · Cited by 88
Cheng, X., Canavan, H. E., Graham, D. J., Castner, D. G., & Ratner, B. D. (2006) · Biointerphases · doi:10.1116/1.2187980 · Cited by 87
Adding Functions to Biomaterial Surfaces through Protein Incorporation
Wrońska, M. A., O’Connor, I. B., Tilbury, M. A., Srivastava, A., & Wall, J. G. (2016) · Advanced Materials · doi:10.1002/adma.201504310 · Cited by 86
Towards the design of universal immunosurfaces for SPR-based assays: A review
Mauriz, E., García-Fernández, M. C., & Lechuga, L. M. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.02.006 · Cited by 82
Dual-Polarization Interferometry: A Novel Technique To Light up the Nanomolecular World
Escorihuela, J., Martínez, M. Á. G., López-Paz, J. L., Puchades, R., Maquieira, Á., & Giménez-Romero, D. (2014) · Chemical Reviews · doi:10.1021/cr5002063 · Cited by 81
North, S. H., Lock, E. H., Cooper, C. J., et al. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100566e · Cited by 79
Oriented immobilization of antibodies on a silicon wafer using Si-tagged protein A
Ikeda, T., Hata, Y., Ninomiya, K.-I., Ikura, Y., Takeguchi, K., Aoyagi, S., Hirota, R., & Kuroda, A. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.11.001 · Cited by 78
Wang, Z., & Jin, G. (2004) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2003.12.012 · Cited by 72
Dostálová, S., Černá, T., Hynek, D., Koudelková, Z., Vaculovič, T., Kopel, P., Hraběta, J., Heger, Z., Vaculovičová, M., Eckschlager, T., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04286 · Cited by 67
Hasan, A., & Pandey, L. M. (2015) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2015.1021488 · Cited by 67
Rosa, A. M. M., Louro, A. F., Martins, S. A. M., Inácio, J., Azevedo, A. M., & Prazeres, D. M. F. (2014) · Analytical Chemistry · doi:10.1021/ac5001288 · Cited by 66
Adsorption orientations and immunological recognition of antibodies on graphene
Vilhena, J. G., Dumitru, A. C., Herruzo, E. T., Mendieta‐Moreno, J. I., Garcia, R. A., Serena, P. A., & Pérez, R. (2016) · Nanoscale · doi:10.1039/c5nr07612a · Cited by 61
Ojeda, I., Barrejón, M., Arellano, L. M., González-Cortés, A., Yáñez‐Sedeño, P., Langa, F., & Pingarrón, J. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.001 · Cited by 58
Schneck, E., Berts, I., Halperin, A., Daillant, J., & Fragneto, G. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.12.041 · Cited by 55
Orientation of llama antibodies strongly increases sensitivity of biosensors
Trilling, A. K., Hesselink, T., van Houwelingen, A. M. M. L., Cordewener, J. H. G., Jongsma, M. A., Schoffelen, S., van Hest, J. C. M., Zuilhof, H. T., & Beekwilder, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.04.017 · Cited by 53
Zhang, J., Sun, Y. X., Wu, Q., Zhang, H., Bai, Y., & Song, D. (2013) · The Analyst · doi:10.1039/c3an01553j · Cited by 50
Biological Selection of Peptides for Poly( l -lactide) Substrates
Matsuno, H., Sekine, J., Yajima, H., & Serizawa, T. (2008) · Langmuir · doi:10.1021/la8008442 · Cited by 50
Versatile protein microarray based on carbohydrate‐binding modules
Ofir, K., Berdichevsky, Y., Benhar, I., Rosenfeld, R., Lamed, R., Barak, Y., Bayer, E. A., & Morag, E. (2005) · PROTEOMICS · doi:10.1002/pmic.200401078 · Cited by 49
Miyakawa, S., Oguro, A., Ohtsu, T., Imataka, H., Sonenberg, N., & Nakamura, Y. (2006) · RNA: A publication of the RNA Society · doi:10.1261/rna.2169406 · Cited by 46
Yu, Q., Wang, Q., Li, B., Lin, Q., & Duan, Y. (2014) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.881249 · Cited by 41
Crivianu-Gaita, V., Aamer, M., Posaratnanathan, R. T., Romaschin, A. D., & Thompson, M. E. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.031 · Cited by 40
Lee, Y., Jeong, J., Lee, G., Moon, J. H., & Lee, M. K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02071 · Cited by 35
Kosobrodova, E., Jones, R., Kondyurin, A. V., Chrzanowski, W., Pigram, P. J., McKenzie, D. R., & Bilek, M. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.02.027 · Cited by 34
Self-citationArenas, C. B., Sánchez‐Tirado, E., Ojeda, I., Gómez‐Suárez, C., González-Cortés, A., Villalonga, R., Yáñez‐Sedeño, P., & Pingarrón, J. M. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.09.055 · Cited by 30
ToF-SIMS and Principal Component Analysis Investigation of Denatured, Surface-Adsorbed Antibodies
Welch, N. G., Madiona, R. M. T., Scoble, J. A., et al. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b02754 · Cited by 29
Self-citationWelch, N. G., Madiona, R. M. T., Payten, T. B., et al. (2016) · Langmuir · doi:10.1021/acs.langmuir.6b02312 · Cited by 27
Self-citationSorted cell microarrays as platforms for high-content informational bioassays
Anglin, E. J., Salisbury, C., Bailey, S., Hor, M., Macardle, P. J., Fenech, M. F., Thissen, H. W., & Voelcker, N. H. (2010) · Lab on a Chip · doi:10.1039/c0lc00185f · Cited by 26
A study of the initial film growth of PEG-like plasma polymer films via XPS and NEXAFS
Li, Y., Muir, B. W., Easton, C. D., Thomsen, L., Nisbet, D. R., & Forsythe, J. S. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.10.022 · Cited by 24
Self-citationCoppari, E., Santini, S., Bizzarri, A. R., & Cannistraro, S. (2016) · Biophysical Chemistry · doi:10.1016/j.bpc.2016.01.002 · Cited by 24
Target replacement strategy for selection of DNA aptamers against the Fc region of mouse IgG
Ma, J., Wang, M. G., Mao, A., et al. (2013) · Genetics and Molecular Research · doi:10.4238/2013.april.25.11 · Cited by 24
Research progress on site-oriented and three-dimensional immobilization of protein
Wang, C., & Feng, B. (2015) · Molecular Biology · doi:10.1134/s0026893315010173 · Cited by 23
Verma, S. K., Amoah, A., Schellhaas, U., Winterhalter, M., Springer, S., & Kolesnikova, T. A. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201601328 · Cited by 23
Proteins at Interfaces III : state of the art
Horbett, T. A., Brash, J. L., & Norde, W. (2012) · Socio-Environmental Systems Modeling · doi:10.1021/bk-2012-1120 · Cited by 22
Yuan, Y., Yin, M., Qian, J., & Liu, C. (2011) · Soft Matter · doi:10.1039/c1sm05086a · Cited by 19
High-Throughput Production of Chromium(III) Complexes for Antibody Immobilization
Welch, N. G., Scoble, J. A., Easton, C. D., et al. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02531 · Cited by 18
Self-citationA chemiluminescent sandwich ELISA enhancement method using a chromium (III) coordination complex
Welch, N. G., Easton, C. D., Scoble, J. A., et al. (2016) · Journal of Immunological Methods · doi:10.1016/j.jim.2016.09.003 · Cited by 14
Self-citationMustafaoğlu, N., Alves, N. J., & Bilgiçer, B. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25558 · Cited by 13
Kumada, Y., Kang, B., Yamakawa, K., Kishimoto, M., & Horiuchi, J. (2015) · Biotechnology Progress · doi:10.1002/btpr.2169 · Cited by 12
Welch, N. G., Madiona, R. M. T., Easton, C. D., et al. (2016) · Biointerphases · doi:10.1116/1.4967442 · Cited by 10
Self-citationSite-directed immobilization antibody for alpha-fetoprotein detection by optical biosensor
Huang, C., Yang, Q., Song, F., Chen, N., Liao, X., Yao, B., Zhang, S., Chen, Y., & Jin, G. (2016) · Integrated ferroelectrics · doi:10.1080/10584587.2016.1172004 · Cited by 6
Investigation of the growth mechanisms of diglyme plasma polymers on amyloid fibril networks
Li, Y., Reynolds, N. P., Styan, K. E., Muir, B. W., Forsythe, J. S., & Easton, C. D. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2015.11.103 · Cited by 2
Self-citation
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
The Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Zhang, L., Mazouzi, Y., Salmain, M., Liedberg, B., & Boujday, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112370 · Cited by 258
Oriented immobilization of antibodies onto sensing platforms - A critical review
Gao, S., Guisán, J. M., & Rocha-Martin, J. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338907 · Cited by 257
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Metadata
- Authors
- Welch, N. G., Scoble, J. A., Muir, B. W., & Pigram, P. J.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2017-03-16
- Volume
- 12
- Issue
- 2
- Pages
- 02D301-02D301
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W2595421984
- Cited by
- 414
- References
- 92
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.