Microfabrication of cantilever styli for the atomic force microscope
Abstract
Atomic force microscopy (AFM) is a newly developed high resolution microscopy technique which is capable of mapping forces near surfaces or, by means of these forces, the topography of the surface itself. In one mode of operation, AFM can resolve individual atoms on both conducting and insulating surfaces. A crucial component for the AFM is a flexible force-sensing cantilever stylus, whose properties should include, among other things: a sharp tip, a low force constant, and a high mechanical resonance frequency. These requirements can be met by reducing the size of the cantilever stylus through microfabrication techniques and employing novel methods to construct a sharp tip. Presented here are a number of microfabrication processes for constructing cantilever styli with properties ideal for the AFM. These fabrication processes include (1) a method for producing thin film SiO2 or Si3N4 cantilevers without tips, (2) a method for producing Si3N4 cantilevers with integrated pyramidal tips formed by using an etch pit on the (100) surface of Si as a mold, (3) a method for producing SiO2 cantilevers with conical tips formed by a combination of isotropic and anisotropic plasma etching of a small Si post, and (4) a method for producing SiO2 cantilevers with integrated tetrahedral tips formed by anisotropically etching a corner of a small Si post to a sharp point. Each of these processes uses a (100) Si wafer as a substrate and relies on conventional batch fabrication techniques. The quality (i.e., sharpness) of the tips produced by the above methods matches or exceeds that of conventional tips used in the AFM or scanning tunneling microscope (STM). Alternative methods for producing tips by evaporation of material through an orifice or by selective chemical vapor deposition of W metal into a pyramidal etch pit in Si have been demonstrated, but these methods have not yet been successfully used in cantilever assemblies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Force-distance curves by atomic force microscopy
Cappella, B., & Dietler, G. (1999) · Surface Science Reports · doi:10.1016/s0167-5729(99)00003-5 · Cited by 1,694
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Sader, J. E. (1998) · Journal of Applied Physics · doi:10.1063/1.368002 · Cited by 1,410
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Micromechanical cantilever-based biosensors
Raiteri, R., Grattarola, M., Butt, H.-J., & Skládal, P. (2001) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)00856-5 · Cited by 734
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Cantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Weisenhorn, A. L., Maivald, P., Butt, H.-J., & Hansma, P. K. (1992) · Physical Review B · doi:10.1103/physrevb.45.11226 · Cited by 485
Noy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Deformation and height anomaly of soft surfaces studied with an AFM
Weisenhorn, A. L., Khorsandi, M., Kasas, S., Gotzos, V, & Butt, H. J. (1993) · Nanotechnology · doi:10.1088/0957-4484/4/2/006 · Cited by 427
Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D. (2005) · Physical Review E · doi:10.1103/physreve.72.021914 · Cited by 421
Surface morphology and mechanical properties of MDCK monolayers by atomic force microscopy
Hoh, J. H., & Schoenenberger, C.-A. (1994) · Journal of Cell Science · doi:10.1242/jcs.107.5.1105 · Cited by 418
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Mechanical detection of magnetic resonance
Rugar, D., Yannoni, C. S., & Sidles, J. A. (1992) · Nature · doi:10.1038/360563a0 · Cited by 395
Measuring elasticity of biological materials by atomic force microscopy
Vinckier, A., & Semenza, G. (1998) · FEBS Letters · doi:10.1016/s0014-5793(98)00592-4 · Cited by 386
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Combined Scanning Electrochemical−Atomic Force Microscopy
Macpherson, J. V., & Unwin, P. R. (2000) · Analytical Chemistry · doi:10.1021/ac990921w · Cited by 383
Structural and functional imaging with carbon nanotube AFM probes
Hafner, J. H., Cheung, C.-L., Woolley, A. T., & Lieber, C. M. (2001) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(01)00011-6 · Cited by 344
Vasudevan, R. K., Balke, N., Maksymovych, P., Jesse, S., & Kalinin, S. V. (2017) · Applied Physics Reviews · doi:10.1063/1.4979015 · Cited by 344
Chon, J. W. M., Mulvaney, P., & Sader, J. E. (2000) · Journal of Applied Physics · doi:10.1063/1.372455 · Cited by 338
Biological atomic force microscopy: what is achieved and what is needed
Shao, Z., Mou, J., Czajkowsky, D. M., Yang, J., & Yuan, J.-Y. (1996) · Advances in Physics · doi:10.1080/00018739600101467 · Cited by 325
A method for determining the spring constant of cantilevers for atomic force microscopy
Torii, A., Sasaki, M., Hane, K., & Okuma, S. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/2/010 · Cited by 282
Introduction to Scanning Tunneling Microscopy
Chen, C. J. (2007) · doi:10.1093/acprof:oso/9780199211500.001.0001 · Cited by 276
Measuring surface forces in aqueous electrolyte solution with the atomic force microscope
Butt, H.-J., Jaschke, M., & Ducker, W. (1995) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(95)01800-t · Cited by 273
Theoretical analysis of the static deflection of plates for atomic force microscope applications
Sader, J. E., & White, L. (1993) · Journal of Applied Physics · doi:10.1063/1.354137 · Cited by 268
Costa, K. D., & Yin, F. C. P. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835074 · Cited by 265
Parallel beam approximation for V-shaped atomic force microscope cantilevers
Sader, J. E. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145292 · Cited by 260
Fritz, J. (2008) · The Analyst · doi:10.1039/b718174d · Cited by 254
Surface chemistry and tip-sample interactions in atomic force microscopy
Senden, T. J., & Drummond, C. J. (1995) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(94)02954-q · Cited by 252
Metadata
- Authors
- Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F.
- Venue
- Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films
- Publisher
- American Vacuum Society
- Published
- 1990-07-01
- Volume
- 8
- Issue
- 4
- Pages
- 3386-3396
- ISSN
- 0734-2101 (ISSN-L)
- 1520-8559
- OpenAlex
- W2128193161
- Cited by
- 747
- References
- 0
- FWCI
- 30.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.