The DOI matches its Crossref record.
Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma
Open accessAbstract
Skin cancer is the most common human malignancy, with basal cell carcinoma (BCC) the most frequent type. Aggressive forms of BCC are associated with extensive dermal invasion and destruction of collagen. Surgery is the most common treatment, but identification of tumor borders is a challenge. Polarization-sensitive optical coherence tomography (PS-OCT) is an optical method to examine collagen birefringence. To date, it has not been exploited for cancer management. As part of a pilot exploratory study to examine the use of OCT in skin cancer, we examined several tumors that pose a challenge to the surgeon due to their large size and histological subtype. In normal perilesional skin, OCT identifies epidermal and dermal structure; PS-OCT identified dermal birefringence. In BCC, tumors lost normal structure and gained the appearance of lobular impressions. PS-OCT identified an alteration of dermal birefringence. Examination of a border area revealed a gradual transition from more normal appearing image to frank tumor. These results indicate that PS-OCT can identify features that distinguish normal skin from tumor and may have the potential to guide surgeons in the treatment of aggressive skin cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Self-citationChromatic Plasmonic Polarizers for Active Visible Color Filtering and Polarimetry
Ellenbogen, T., Seo, K., & Crozier, K. B. (2012) · Nano Letters · doi:10.1021/nl204257g · Cited by 416
Color generation via subwavelength plasmonic nanostructures
Gu, Y., Zhang, L., Yang, J. K. W., Yeo, S. P., & Qiu, C.-W. (2015) · Nanoscale · doi:10.1039/c5nr00578g · Cited by 311
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Advances in Optical Coherence Tomography Imaging for Dermatology
Pierce, M. C., Strasswimmer, J., Hyle Park, B., Cense, B., & de Boer, J. F. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23404.x · Cited by 257
Self-citationColors with plasmonic nanostructures: A full-spectrum review
Song, M., Wang, D., Peana, S., Choudhury, S., Nyga, P., Kudyshev, Z. A., Yu, H., Boltasseva, A., Shalaev, V. M., & Kildishev, A. V. (2019) · Applied Physics Reviews · doi:10.1063/1.5110051 · Cited by 212
Advances in optical coherence tomography in dermatology—a review
Olsen, J., Holmes, J., & Jemec, G. B. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.040901 · Cited by 165
Applications and future directions for optical coherence tomography in dermatology*
Wan, B., Ganier, C., Du‐Harpur, X., Harun, N., Watt, F. M., Patalay, R., & Lynch, M. D. (2021) · British Journal of Dermatology · doi:10.1111/bjd.19553 · Cited by 148
Optical coherence tomography for the characterization of basal cell carcinoma in vivo: A pilot study
Olmedo, J. M., Warschaw, K. E., Schmitt, J. M., & Swanson, D. L. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.03.013 · Cited by 120
Cheng, H. M., & Guitera, P. (2015) · British Journal of Dermatology · doi:10.1111/bjd.14042 · Cited by 65
Metadata
- Authors
- Strasswimmer, J., Pierce, M. C., Park, B. H., Neel, V., & de Boer, J. F.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2004
- Volume
- 9
- Issue
- 2
- Pages
- 292
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2158385894
- Cited by
- 167
- References
- 0
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.