Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning
Open accessThe DOI matches its Crossref record.
Abstract
We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located distal to the lenses rotates along the orthogonal axes to produce arc-surface images over a large field of view (FOV). With fiber optic coupling, this microscope can potentially be scaled down to millimeter dimensions via microelectromechanical systems (MEMS) technology. We demonstrate a benchtop prototype with a spatial resolution < or =4.4 microm that collects fluorescence images with a high SNR and a good contrast ratio from specimens expressing GFP. Furthermore, the scanning mechanism produces only small differences in aberrations over the image FOV. These results demonstrate proof of concept of the dual-axis confocal architecture for in vivo molecular and cellular imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
“Confocal or 2P/MP microscopy permits diffraction-limited longitudinal imaging of tissues in vivo (intravital imaging) using invasive procedures such as implantable windows or fiber based catheters and objectives placed on the surface of interest and imaged in epi-illumination mod”
MethodPrinciples of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Fiber-optic fluorescence imaging
Flusberg, B. A., Cocker, E. D., Piyawattanametha, W., Jung, J. C., Cheung, E. L. M., & Schnitzer, M. J. (2005) · Nature Methods · doi:10.1038/nmeth820 · Cited by 732
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Optical biopsy: A new frontier in endoscopic detection and diagnosis
Wang, T. D., & Van Dam, J. (2004) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00345-3 · Cited by 202
Self-citationMultispectral fluorescence lifetime imaging by TCSPC
Becker, W., Bergmann, A., & Biskup, C. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20432 · Cited by 159
Metadata
- Authors
- Wang, T. D., Contag, C. H., Mandella, M. J., Chan, N. Y., & Kino, G. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2004
- Volume
- 9
- Issue
- 4
- Pages
- 735
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2123860697
- Cited by
- 48
- References
- 0
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.