The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging
Open accessAbstract
Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this problem employed temporal filtering, estimation of systemic effects from background pixels, or modeling of interference signals with predefined basis functions, with some success. However, weak signals are still lost in the interference, and other complementary methods are desirable. We use the spatial behavior of measured baseline signals to identify the interference subspaces. We then project signals components in this subspace out of the stimulation data. In doing so, we assume that systemic interference components will be more global spatially, with higher energy, than the stimulus-evoked signals of interest. Thus, the eigenvectors corresponding to the largest eigenvalues of an appropriate correlation matrix form the basis for an interference subspace. By projecting the data onto the orthogonal nullspace of these eigenvectors, we can obtain more localized response, as reflected in improved contrast-to-noise ratio and correlation coefficient maps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Discrete Random Signals and Statistical Signal Processing
Therrien, C. W. (1992) · Cited by 1,288
Villringer, A., Planck, J., Hock, C., Schleinkofer, L., & Dirnagl, U. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90181-j · Cited by 1,119
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Hoshi, Y., & Tamura, M. (1993) · Neuroscience Letters · doi:10.1016/0304-3940(93)90094-2 · Cited by 466
Spectral analysis of blood pressure and heart rate in conscious rats: effects of autonomic blockers
Japundzic, N., Grichois, M.-L., Zitoun, P., Laude, D., & Elghozi, J.-L. (1990) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(90)90132-3 · Cited by 384
Millikan, G. A. (1942) · Review of Scientific Instruments · doi:10.1063/1.1769941 · Cited by 331
Functional MRI cerebral activation and deactivation during finger movement
Allison, J. D., Meador, K. J., Loring, D. W., Figueroa, R. E., & Wright, J. C. (2000) · Neurology · doi:10.1212/wnl.54.1.135 · Cited by 316
Franceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A. (2003) · Psychophysiology · doi:10.1111/1469-8986.00057 · Cited by 275
Self-citationOn-line optical imaging of the human brain with 160-ms temporal resolution
Franceschini, M. A., Toronov, V., Filiaci, M. E., Gratton, E., & Fantini, S. (2000) · Optics Express · doi:10.1364/oe.6.000049 · Cited by 237
Self-citationToronov, V., Franceschini, M. A., Filiaci, M., Fantini, S., Wolf, M., Michalos, A., & Gratton, E. (2000) · Medical Physics · doi:10.1118/1.598943 · Cited by 169
Self-citationTime-series estimation of biological factors in optical diffusion tomography
Prince, S. J. D., Kolehmainen, V., Kaipio, J. P., Franceschini, M. A., Boas, D. A., & Arridge, S. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/301 · Cited by 112
Self-citationFranceschini, M. A., Boas, D. A., Zourabian, A., Diamond, S. G., Nadgir, S., Lin, D. W., Moore, J. B., & Fantini, S. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.372 · Cited by 94
Self-citationImprovement of the earpiece oximeter
Aoyagi, T. (1974) · Medical Entomology and Zoology · Cited by 86
Spontaneous Fluctuations in Cerebral Oxygen Supply
Hudetz, A. G., Biswal, B. B., Shen, H., Lauer, K. K., & Kampine, J. P. (1998) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4863-8_66 · Cited by 79
Noninvasive Imaging of Cerebral Activation with Diffuse Optical Tomography
Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2009) · Frontiers in neuroscience · doi:10.1201/9781420076851.ch14 · Cited by 66
Self-citationFranceschini, M. A., Gratton, E., & Fantini, S. (1999) · Optics Letters · doi:10.1364/ol.24.000829 · Cited by 66
Self-citationWolf, M., Duc, G. V., Keel, M., Niederer, P. F., von Siebenthal, K., & Bucher, H.-U. (1997) · Critical Care Medicine · doi:10.1097/00003246-199709000-00028 · Cited by 55
Analysis of a periodic breathing pattern associated with Mayer waves
Preiss, G., Iscoe, S., & Polosa, C. (1975) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1975.228.3.768 · Cited by 51
Sliwka, U., Harscher, S., Diehl, R. R., van Schayck, R., Niesen, W., & Weiller, C. (2001) · Headache The Journal of Head and Face Pain · doi:10.1111/j.1526-4610.2001.hed01027.x · Cited by 50
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
Self-citationfNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
A quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Metadata
- Authors
- Zhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2005
- Volume
- 10
- Issue
- 1
- Pages
- 011014
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2002994039
- Cited by
- 373
- References
- 22
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.