Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 333

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Emission spectra of bioluminescent reporters and interaction with mammalian tissue determine the sensitivity of detection in vivo

Open access
Zhao, Hui, Doyle, Timothy C., Coquoz, Olivier, Kalish, Flora, Rice, Bradley W., Contag, Christopher H.·2005·Journal of Biomedical Optics

Abstract

In vivo bioluminescence imaging depends on light emitted by luciferases in the body overcoming the effect of tissue attenuation. Understanding this relationship is essential for detection and quantification of signal. We have studied four codon optimized luciferases with different emission spectra, including enzymes from firefly (FLuc), click beetle (CBGr68, CBRed) and Renilla reniformins (hRLuc). At 25 degrees C, the in vitro lambda(max) of these reporters are 578, 543, 615, and 480 nm, respectively; at body temperature, 37 degrees C, the brightness increases and the firefly enzyme demonstrates a 34-nm spectral red shift. Spectral shifts and attenuation due to tissue effects were evaluated using a series of 20-nm bandpass filters and a cooled charge-coupled device (CCD) camera. Attenuation increased and the spectra of emitted light was red shifted for signals originating from deeper within the body relative to superficial origins. The tissue attenuation of signals from CBGr68 and hRLuc was greater than from those of Fluc and CBRed. To further probe tissue effects, broad spectral emitters were created through gene fusions between CBGr68 and CBRed. These resulted in enzymes with broader emission spectra, featuring two peaks whose intensities are differentially affected by temperature and tissue depth. These spectral measurement data allow for improved understanding of how these reporters can be used in vivo and what they can reveal about biological processes in living subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.2032388

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 333

Metadata

Authors
Zhao, H., Doyle, T. C., Coquoz, O., Kalish, F., Rice, B. W., & Contag, C. H.
Venue
Journal of Biomedical Optics
Published
2005
Volume
10
Issue
4
Pages
041210
ISSN
1083-3668 (ISSN-L)
OpenAlex
W1973804925
Cited by
333
References
18
FWCI
6.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Emission spectra of bioluminescent reporters and interaction with mammalian tissue determine the sensitivity of detection in vivo. https://app.cochat.ai/papers/10.1117/1.2032388
The paper
Zhao, H., Doyle, T. C., Coquoz, O., Kalish, F., Rice, B. W., & Contag, C. H. (2005). Emission spectra of bioluminescent reporters and interaction with mammalian tissue determine the sensitivity of detection in vivo. Journal of Biomedical Optics. https://doi.org/10.1117/1.2032388

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.