The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Characterization of atherosclerosis plaques by measuring both backscattering and attenuation coefficients in optical coherence tomography
Open accessAbstract
Intravascular optical coherence tomography (OCT) has been proven a powerful diagnostic tool for cardiovascular diseases. However, the optical mechanism for the qualitative observations are still absent. We address the fundamental issues that underlie the tissue characterization of OCT images obtained from coronary arteries. For this, we investigate both the attenuation and the backscattering properties of different plaque components of postmortem human cadaver coronary arteries. The artery samples are examined both from lumen surface using a catheter and from transversely cut surface using an OCT microscope, where OCT images could be matched to histology exactly. Light backscattering coefficient microb and attenuation coefficients microt are determined for three basic plaque types based on a single-scattering physical model: calcification (microb=4.9+/-1.5 mm(-1), microt=5.7+/-1.4 mm(-1)), fibers (microb=18.4+/-6.4 mm(-1), microt=6.4+/-1.2 mm(-1)), and lipid pool (microb=28.1+/-8.9 mm(-1), microt=13.7+/-4.5 mm(-1)). Our results not only explain the origins of many qualitative OCT features, but also show that combination of backscattering and attenuation coefficient measurements can be used for contrast enhancing and better tissue characterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Virmani, R., Kolodgie, F. D., Burke, A. P., Farb, A., & Schwartz, S. M. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.5.1262 · Cited by 4,084
Self-citationFalk, E., Shah, P. K., & Fuster, V. (1995) · Circulation · doi:10.1161/01.cir.92.3.657 · Cited by 3,536
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Jang, I.-K., Bouma, B. E., Kang, D.-H., Park, S.-J., Park, S.-W., Seung, K.-B., Choi, K.-B., Shishkov, M., Schlendorf, K., Pomerantsev, E., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01799-5 · Cited by 1,000
Stability and Instability: Two Faces of Coronary Atherosclerosis: The Paul Dudley White Lecture 1995
Davies, M. J. (1996) · Circulation · doi:10.1161/01.cir.94.8.2013 · Cited by 915
In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography
Jang, I.-K., Tearney, G. J., MacNeill, B., Takano, M., Moselewski, F., Iftima, N., Shishkov, M., Houser, S., Aretz, H. T., Halpern, E. F., et al. (2005) · Circulation · doi:10.1161/01.cir.0000159354.43778.69 · Cited by 896
Assessment of Culprit Lesion Morphology in Acute Myocardial Infarction
Kubo, T., Imanishi, T., Takarada, S., Kuroi, A., Ueno, S., Yamano, T., Tanimoto, T., Matsuo, Y., Masho, T., Kitabata, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.082 · Cited by 867
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Comprehensive volumetric optical microscopy in vivo
Yun, S. H., Tearney, G. J., Vakoc, B. J., Shishkov, M., Oh, W. Y., Desjardins, A. E., Suter, M. J., Chan, R. C., Evans, J. A., Jang, I.-K., et al. (2006) · Nature Medicine · doi:10.1038/nm1450 · Cited by 438
Measurement of optical properties of biological tissues by low-coherence reflectometry
Schmitt, J. M., Knüttel, A., & Bonner, R. F. (1993) · Applied Optics · doi:10.1364/ao.32.006032 · Cited by 355
Self-citationMeasurement of the thickness of the fibrous cap by optical coherence tomography
Kume, T., Akasaka, T., Kawamoto, T., Okura, H., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.030 · Cited by 273
Nadkarni, S. K., Pierce, M. C., Park, B. H., de Boer, J. F., Whittaker, P., Bouma, B. E., Bressner, J. E., Halpern, E., Houser, S. L., & Tearney, G. J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.11.040 · Cited by 223
Anisotropy in the absorption and scattering spectra of chicken breast tissue
Marquez, G., Wang, L. V., Lin, S.-P., Schwartz, J. A., & Thomsen, S. L. (1998) · Applied Optics · doi:10.1364/ao.37.000798 · Cited by 215
Levitz, D., Thrane, L., Frosz, M. H., Andersen, P. E., Andersen, C. B., Andersson-Engels, S., Valanciunaite, J., Swartling, J., & Hansen, P. R. (2004) · Optics Express · doi:10.1364/opex.12.000249 · Cited by 191
van der Meer, F. J., Faber, D. J., Sassoon, D. M. B., Aalders, M. C. G., Pasterkamp, G., & van Leeuwen, T. G. J. M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.854297 · Cited by 160
Giattina, S. D., Courtney, B. K., Herz, P. R., Harman, M., Shortkroff, S., Stamper, D. L., Liu, B., Fujimoto, J. G., & Brezinski, M. E. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.11.036 · Cited by 153
Precision of measurement of tissue optical properties with optical coherence tomography
Kholodnykh, A. I., Petrova, I. Y., Larin, K. V., Motamedi, M., & Esenaliev, R. O. (2003) · Applied Optics · doi:10.1364/ao.42.003027 · Cited by 106
Liu, B., & Brezinski, M. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2753410 · Cited by 105
Quantitative optical coherence tomography of arterial wall components
van der Meer, F. J., Faber, D. J., Perrée, J., Pasterkamp, G., Sassoon, D. M. B., & van Leeuwen, T. G. J. M. (2005) · Lasers in Medical Science · doi:10.1007/s10103-005-0336-z · Cited by 57
Cited by
Vermeer, K. A., Mo, J., Weda, J. J. A., Lemij, H. G., & de Boer, J. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000322 · Cited by 373
Chang, S., & Bowden, A. K. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.9.090901 · Cited by 99
Metadata
- Authors
- Xu, C., Schmitt, J. M., Carlier, S. G., & Virmani, R.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2008
- Volume
- 13
- Issue
- 3
- Pages
- 034003
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2108345603
- Cited by
- 255
- References
- 19
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.