Laser optoacoustic imaging system for detection of breast cancer
Open accessAbstract
We designed, fabricated and tested the laser optoacoustic imaging system for breast cancer detection (LOIS-64), which fuses optical and acoustic imaging techniques in one modality by utilizing pulsed optical illumination and ultrawide-band ultrasonic detection of resulting optoacoustic (OA) signals. The system was designed to image a single breast slice in craniocaudal or mediolateral projection with an arc-shaped array of 64 ultrawide-band acoustic transducers. The system resolution on breast phantoms was at least 0.5 mm. The single-channel sensitivity of 1.66 mVPa was estimated to be sufficient for single-pulse imaging of 6 to 11 mm tumors through the whole imaging slice of the breast. The implemented signal processing using the wavelet transform allowed significant reduction of the low-frequency (LF) acoustic noise, allowed localization of the optoacoustic signals from tumors, and enhanced the contrast and sharpened the boundaries of the optoacoustic images of the tumors. During the preliminary clinical studies on 27 patients, the LOIS-64 was able to visualize 18 out of 20 malignant lesions suspected from mammography and ultrasound images and confirmed by the biopsy performed after the optoacoustic tomography (OAT) procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer Cell Imaging and Photothermal Therapy in the Near-Infrared Region by Using Gold Nanorods
Huang, X., El-Sayed, I. H., Qian, W., & El-Sayed, M. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja057254a · Cited by 5,436
Strang, G., & Nguyen, T. Q. (1996) · Cited by 4,180
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“9 16 OAT of breast cancer takes advantage of the enhanced optical absorption of blood-rich tumors 17,18 and relatively high optical trans-parency of normal tissues 19 in the near-infrared (cid:1) NIR (cid:2) optical range.”
BackgroundPhysical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Acoustic waves : devices, imaging, and analog signal processing
Kino, G. S. (1987) · Prentice Hall eBooks · Cited by 1,277
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Strang, G. (1996) · Wavelets · doi:10.1093/oso/9780195094237.003.0002 · Cited by 1,205
MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Orel, S. G., & Schnall, M. D. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl3113 · Cited by 759
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Veronesi, U., Boyle, P., Goldhirsch, A., Orecchia, R., & Viale, G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)66546-4 · Cited by 542
Role of Angiogenesis in Human Tumor Dormancy: Animal Models of the Angiogenic Switch
Naumov, G. N., Akslen, L. A., & Folkman, J. (2006) · Cell Cycle · doi:10.4161/cc.5.16.3018 · Cited by 500
Hirsch, L. R., Gobin, A. M., Lowery, A. R., Tam, F., Drezek, R. A., Halas, N. J., & West, J. L. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9001-8 · Cited by 497
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461
Cerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Photoacoustic monopole radiation in one, two, and three dimensions
Diebold, G. J., Sun, T., & Khan, M. I. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.3384 · Cited by 353
Oraevsky, A. A., Jacques, S. L., & Tittel, F. K. (1997) · Applied Optics · doi:10.1364/ao.36.000402 · Cited by 298
Self-citationManohar, S., Vaartjes, S. E., van Hespen, J. C. G., Klaase, J. M., van den Engh, F. M., Steenbergen, W., & van Leeuwen, T. G. (2007) · Optics Express · doi:10.1364/oe.15.012277 · Cited by 287
Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors
Esenaliev, R. O., Karabutov, A. A., & Oraevsky, A. A. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796320 · Cited by 239
Self-citationThermoacoustic and Photoacoustic Tomography of Thick Biological Tissues toward Breast Imaging
Ku, G., Fornage, B. D., Jin, X., Xu, M., Hunt, K. K., & Wang, L. V. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400509 · Cited by 170
Detection of ultrawide-band ultrasound pulses in optoacoustic tomography
Андреев, В. Г., Karabutov, A. A., & Oraevsky, A. A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1244756 · Cited by 131
Self-citationGrosenick, D., Wabnitz, H., Moesta, K. T., Mucke, J., Schlag, P. M., & Rinneberg, H. H. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/002 · Cited by 129
Mobley, J., Vo‐Dinh, T., & Tuchin, V. V. (2014) · CRC Press eBooks · doi:10.1201/b17290-8 · Cited by 123
Taroni, P., Torricelli, A. M., Spinelli, L., Pifferi, A., Arpaia, F., Danesini, G. M., & Cubeddu, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/003 · Cited by 116
An overview of the status of imaging screening technology for breast cancer
Smith, J. A., & Andreopoulou, E. (2004) · Annals of Oncology · doi:10.1093/annonc/mdh653 · Cited by 91
Angiogenesis, thrombospondin, and ductal carcinoma in situ of the breast
Rice, A. J., & Quinn, C. M. (2002) · Journal of Clinical Pathology · doi:10.1136/jcp.55.8.569 · Cited by 90
Characterization of female breast lesions from multi-wavelength time-resolved optical mammography
Spinelli, L., Torricelli, A. M., Pifferi, A., Taroni, P., Danesini, G. M., & Cubeddu, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/004 · Cited by 87
New technologies in screening for breast cancer: a systematic review of their accuracy
Irwig, L., Houssami, N., & van Vliet, C. (2004) · British Journal of Cancer · doi:10.1038/sj.bjc.6601836 · Cited by 82
Heritabilities and paradigm shifts
Alatalo, R. V., Mappes, J., & Elgar, M. A. (1997) · Nature · doi:10.1038/385402a0 · Cited by 81
Functional magnetic resonance imaging in oncology for diagnosis and therapy monitoring.
Knopp, M. V., von Tengg‐Kobligk, H., & Choyke, P. L. (2003) · PubMed · Cited by 72
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Kircher, M. F., de la Zerda, A., Jokerst, J. V., Zavaleta, C. L., Kempen, P. J., Mittra, E., Pitter, K., Huang, R., Campos, C., Habte, F., et al. (2012) · Nature Medicine · doi:10.1038/nm.2721 · Cited by 1,064
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Metadata
- Authors
- Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2009
- Volume
- 14
- Issue
- 2
- Pages
- 024007
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2026343913
- Cited by
- 493
- References
- 30
- FWCI
- 26.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.