The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Laser optoacoustic imaging system for detection of breast cancer
Open accessAbstract
We designed, fabricated and tested the laser optoacoustic imaging system for breast cancer detection (LOIS-64), which fuses optical and acoustic imaging techniques in one modality by utilizing pulsed optical illumination and ultrawide-band ultrasonic detection of resulting optoacoustic (OA) signals. The system was designed to image a single breast slice in craniocaudal or mediolateral projection with an arc-shaped array of 64 ultrawide-band acoustic transducers. The system resolution on breast phantoms was at least 0.5 mm. The single-channel sensitivity of 1.66 mVPa was estimated to be sufficient for single-pulse imaging of 6 to 11 mm tumors through the whole imaging slice of the breast. The implemented signal processing using the wavelet transform allowed significant reduction of the low-frequency (LF) acoustic noise, allowed localization of the optoacoustic signals from tumors, and enhanced the contrast and sharpened the boundaries of the optoacoustic images of the tumors. During the preliminary clinical studies on 27 patients, the LOIS-64 was able to visualize 18 out of 20 malignant lesions suspected from mammography and ultrasound images and confirmed by the biopsy performed after the optoacoustic tomography (OAT) procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer Cell Imaging and Photothermal Therapy in the Near-Infrared Region by Using Gold Nanorods
Huang, X., El-Sayed, I. H., Qian, W., & El-Sayed, M. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja057254a · Cited by 5,436
Strang, G., & Nguyen, T. Q. (1996) · Cited by 4,180
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“9 16 OAT of breast cancer takes advantage of the enhanced optical absorption of blood-rich tumors 17,18 and relatively high optical trans-parency of normal tissues 19 in the near-infrared (cid:1) NIR (cid:2) optical range.”
BackgroundPhysical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Acoustic waves : devices, imaging, and analog signal processing
Kino, G. S. (1987) · Prentice Hall eBooks · Cited by 1,277
Universal back-projection algorithm for photoacoustic computed tomography
Xu, M., & Wang, L. V. (2005) · Physical Review E · doi:10.1103/physreve.71.016706 · Cited by 1,243
Strang, G. (1996) · Wavelets · doi:10.1093/oso/9780195094237.003.0002 · Cited by 1,205
MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Orel, S. G., & Schnall, M. D. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl3113 · Cited by 759
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Cited by
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Kircher, M. F., de la Zerda, A., Jokerst, J. V., Zavaleta, C. L., Kempen, P. J., Mittra, E., Pitter, K., Huang, R., Campos, C., Habte, F., et al. (2012) · Nature Medicine · doi:10.1038/nm.2721 · Cited by 1,064
A review of clinical photoacoustic imaging: Current and future trends
Attia, A. B. E., Balasundaram, G., Moothanchery, M., Dinish, U. S., Bi, R., Ntziachristos, V., & Olivo, M. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.100144 · Cited by 878
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Photoacoustic tomography and sensing in biomedicine
Li, C., & Wang, L. V. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/r01 · Cited by 669
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Advances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
In vivo magnetic enrichment and multiplex photoacoustic detection of circulating tumour cells
Galanzha, E. I., Shashkov, E. V., Kelly, T., Kim, J.-W., Yang, L., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.333 · Cited by 575
Molecular imaging: current status and emerging strategies
Pysz, M. A., Gambhir, S. S., & Willmann, J. K. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.03.011 · Cited by 572
Photoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
Nanoparticles as contrast agents for in-vivo bioimaging: current status and future perspectives
Hahn, M. A., Singh, A. K., Sharma, P., Brown, S. C., & Moudgil, B. M. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4207-5 · Cited by 485
Light In and Sound Out: Emerging Translational Strategies for Photoacoustic Imaging
Zackrisson, S., van de Ven, S. M. W. Y., & Gambhir, S. S. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2387 · Cited by 480
Single-breath-hold photoacoustic computed tomography of the breast
Lin, L., Hu, P., Shi, J., Appleton, C. M., Maslov, K., Li, L., Zhang, R., & Wang, L. V. (2018) · Nature Communications · doi:10.1038/s41467-018-04576-z · Cited by 454
Jiang, Y., Upputuri, P. K., Xie, C., Lyu, Y., Zhang, L., Xiong, Q., Pramanik, M., & Pu, K. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02106 · Cited by 395
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Photoacoustic imaging of living mouse brain vasculature using hollow gold nanospheres
Lu, W., Huang, Q., Ku, G., Wen, X., Zhou, M., Guzatov, D., Brecht, P., Su, R., Oraevsky, A., Wang, L. V., et al. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.007 · Cited by 325
Self-citationPhotoacoustics: a historical review
Manohar, S., & Razansky, D. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000586 · Cited by 319
Volumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309
Whole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304
Self-citationPhotoacoustic angiography of the breast
Kruger, R. A., Lam, R. B., Reinecke, D. R., Del Rio, S. P., & Doyle, R. P. (2010) · Medical Physics · doi:10.1118/1.3497677 · Cited by 302
Toi, M., Asao, Y., Matsumoto, Y., Sekiguchi, H., Yoshikawa, A., Takada, M., Kataoka, M., Endo, T., Kawaguchi-Sakita, N., Kawashima, M., et al. (2017) · Scientific Reports · doi:10.1038/srep41970 · Cited by 273
Wendler, T., van Leeuwen, F. W. B., Navab, N., & van Oosterom, M. N. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05445-6 · Cited by 73
Metadata
- Authors
- Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2009
- Volume
- 14
- Issue
- 2
- Pages
- 024007
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2026343913
- Cited by
- 493
- References
- 30
- FWCI
- 26.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.