General equation for the differential pathlength factor of the frontal human head depending on wavelength and age
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Continuous-wave near-infrared spectroscopy and near-infrared imaging enable the measurement of relative concentration changes in oxy- and deoxyhemoglobin and thus hemodynamics and oxygenation. The accuracy of determined changes depends mainly on the modeling of the light transport through the probed tissue. Due to the highly scattering nature of tissue, the light path is longer than the source-detector separation (d). This is incorporated in modeling by multiplying d by a differential pathlength factor (DPF) which depends on several factors such as wavelength, age of the subject, and type of tissue. In the present work, we derive a general DPF equation for the frontal human head, incorporating dependency on wavelength and age, based on published data. We validated the equation using different data sets of experimentally determined DPFs from six independent studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
A method for the solution of certain non-linear problems in least squares
Levenberg, K. (1944) · Quarterly of Applied Mathematics · doi:10.1090/qam/10666 · Cited by 12,359
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Self-citationCEREBRAL BLOOD FLOW, BLOOD VOLUME AND OXYGEN UTILIZATION: NORMAL VALUES AND EFFECT OF AGE
LEENDERS, K. L., PERANI, D., LAMMERTSMA, A. A., HEATHER, J. D., BUCKINGHAM, P., JONES, T., HEALY, M. J. R., GIBBS, J. M., WISE, R. J. S., HATAZAWA, J., et al. (1990) · Brain · doi:10.1093/brain/113.1.27 · Cited by 1,093
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Age-related changes in grey and white matter structure throughout adulthood
Giorgio, A., Santelli, L., Tomassini, V., Bosnell, R., Smith, S., De Stefano, N., & Johansen-Berg, H. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.004 · Cited by 532
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
Boas, D. A., Gaudette, T., Strangman, G., Cheng, X., Marota, J. J. A., & Mandeville, J. B. (2001) · NeuroImage · doi:10.1006/nimg.2000.0674 · Cited by 459
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002915 · Cited by 364
Fukui, Y., Ajichi, Y., & Okada, E. (2003) · Applied Optics · doi:10.1364/ao.42.002881 · Cited by 286
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277 · cited 1×
“From the mathematical point of view, the dependence of d on the DPF is negligible when the inequality d ffiffiffiffiffiffiffiffiffiffiffi 3μaμ 0 s p ≫ 1 holds.(8) Since Eq.”
BackgroundOkada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
IN VIVO and POST MORTEM MEASUREMENTS OF THE ATTENUATION SPECTRA OF LIGHT IN MAMMALIAN TISSUES
Wilson, B. C., Jeeves, W. P., & Lowe, D. M. (1985) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1985.tb01554.x · Cited by 229
Murphy, D. G. M., DeCarli, C., Schapiro, M. B., Rapoport, S. I., & Horwitz, B. (1992) · Archives of Neurology · doi:10.1001/archneur.1992.00530320063013 · Cited by 214
Spectral dependence of temporal point spread functions in human tissues
Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T. (1993) · Applied Optics · doi:10.1364/ao.32.000418 · Cited by 195
Intracranial volume change in childhood
Sgouros, S., Goldin, J. H., Hockley, A. D., Wake, M. J. C., & Natarajan, K. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.91.4.0610 · Cited by 193
An investigation of light transport through scattering bodies with non-scattering regions
Firbank, M., Arridge, S. R., Schweiger, M., & Delpy, D. T. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/4/012 · Cited by 189
Age changes in bone mineralization, cortical thickness, and Haversian canal area
Thompson, D. D. (1980) · Calcified Tissue International · doi:10.1007/bf02407161 · Cited by 168
Cooper, C. E., Elwell, C. E., Meek, J. H., Matcher, S. J., Wyatt, J. S., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199601000-00005 · Cited by 155
Zhao, H., Tanikawa, Y., Gao, F., Onodera, Y., Sassaroli, A., Tanaka, K., & Yamada, Y. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/306 · Cited by 152
Uludaǧ, K., Kohl‐Bareis, M., Steinbrink, J. M., Obrig, H., & Villringer, A. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1427048 · Cited by 139
Kohl‐Bareis, M., Nolte, C. H., Heekeren, H. R., Horst, S., Scholz, U., Obrig, H., & Villringer, A. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/6/028 · Cited by 131
Effect of temperature on the optical properties of ex vivo human dermis and subdermis
Laufer, J., Simpson, R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/004 · Cited by 99
Two Robust Alternatives to Least-Squares Regression
Hill, R. W., & Holland, P. W. (1977) · Journal of the American Statistical Association · doi:10.1080/01621459.1977.10479965 · Cited by 82
Franceschini, M. A., Gratton, E., & Fantini, S. (1999) · Optics Letters · doi:10.1364/ol.24.000829 · Cited by 66
The Effect of Optode Positioning on Optical Pathlength in Near Infrared Spectroscopy of Brain
van der Zee, P., Arridge, S., Cope, M., & Delpy, D. T. (1990) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-8181-5_11 · Cited by 62
A quantitative measure of myelination development in infants, using MR images
Carmody, D. P., DUNN, S. M., Boddie-Willis, A. S., DeMarco, J. K., & Lewis, M. (2004) · Neuroradiology · doi:10.1007/s00234-004-1241-z · Cited by 61
Oxygen Transport to Tissue XII
Piiper, J., Goldstick, T. K., & Meyer, M. (1990) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-8181-5 · Cited by 59
Kohl‐Bareis, M., Lindauer, U., Dirnagl, U., & Villringer, A. (1998) · Optics Letters · doi:10.1364/ol.23.000555 · Cited by 54
Okada, E., Schweiger, M. J., Arridge, S., Firbank, M., & Delpy, D. T. (1996) · Applied Optics · doi:10.1364/ao.35.003362 · Cited by 52
Continuous correction of differential path length factor in near-infrared spectroscopy
Talukdar, T., Diamond, S. G., & Moore, J. H. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.5.056001 · Cited by 37
Liebert, A., Wabnitz, H., & Elster, C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.057005 · Cited by 35
Probabilistic MRI Brain Anatomical Atlases Based on 1,000 Chinese Subjects
Wang, X., Chen, N., ZhenTao, Z., Xue, R., Luo, J., Zhuo, Y., Shen, D. G., & Li, K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0050939 · Cited by 26
Changes in diffusion path length with old age in diffuse optical tomography
Bonnéry, C., Desjardins, M., Pouliot, P., Lesage, F., Leclerc, P.-O., Hoge, R. D., & Bherer, L. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056002 · Cited by 24
Cited by
Best practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Self-citationReindl, V., Gerloff, C., Scharke, W., & Konrad, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.060 · Cited by 411
“The differential pathlength factor was calculated with dependence on wavelength and the participants' individual age (Scholkmann and Wolf, 2013).”
Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin
Kim, J., Salvatore, G. A., Araki, H., Chiarelli, A. M., Xie, Z., Banks, A., Sheng, X., Liu, Y., Lee, J. W., Jang, K.-I., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600418 · Cited by 403
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Self-citation
Metadata
- Authors
- Scholkmann, F., & Wolf, M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-10-11
- Volume
- 18
- Issue
- 10
- Pages
- 105004
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2168226253
- Cited by
- 450
- References
- 40
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.