Cited by 69Advancements in Photolithography TechniquesAdvanced optical system designAdvanced X-ray Imaging Techniques

EUV lithography optics for sub-9nm resolution

Kneer, Bernhard, Migura, Sascha, Kaiser, Winfried, Neumann, Jens Timo, van Schoot, Jan·2015·SPIE Proceedings

Abstract

EUV lithography for resolution below 9 nm requires the numerical aperture of the projection optics to be significantly larger than 0.45. A configuration of 4x magnification, full field size and 6’’ reticle is not feasible anymore. The increased chief ray angle and higher NA at reticle lead to non-acceptable shadowing effects, which can only be controlled by increasing the magnification, hence reducing the system productivity. We demonstrate that the best compromise in imaging, productivity and field split is a so-called anamorphic magnification and a half field of 26 x 16.5 mm². We discuss the optical solutions for anamorphic high-NA lithography.

Integrity signals

Registry

Crossref · 10.1117/12.2175488

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Next-generation EUV scanners with an NA of 0.55 (high-NA) will be used for research and development in 2024-2025 and in high-volume manufacturing in 2025-2026.

    “the next generation of EUV scanners with an NA of 0.55, referred to as high-NA systems, will be used for research and development in 2024-2025 and in HVM in 2025-2026 35-37 .”

    From Extreme ultraviolet lithography (2024) · cites this paper as [35]

  • Modern EUV scanners used in high-volume manufacturing have an NA of 0.33.

    “Modern EUV scanners used in HVM have an NA of 0.33”

    From Extreme ultraviolet lithography (2024) · cites this paper as [35]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kneer, B., Migura, S., Kaiser, W., Neumann, J. T., & van Schoot, J.
Venue
SPIE Proceedings
Publisher
SPIE
Published
2015-03-16
Volume
9422
Pages
94221G
ISSN
0277-786X (ISSN-L)
OpenAlex
W2011236388
Cited by
69
References
3
Citations by year
2026: 1 · 2025: 5 · 2024: 9 · 2023: 4 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 9 · 2016: 11 · 2015: 14
FWCI
15.69
Type
conference paper
Language
en
Open access
closed
Locations
Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
Funders
Bundesministerium für Bildung und Forschung
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Photolithography Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced optical system design
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
Keywords
EUV lithography, high numerical aperture, projection optics, shadowing, magnification, reticle

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review