CoChat

Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers

Gibbs, Peter T., Wood, Levi B., Asada, H. Harry · 2005 · SPIE Proceedings
Cited by 41

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This paper presents an active noise cancellation technique for recovering wearable biosensor signals corrupted by bodily motion. A finger mounted photoplethysmograph (PPG) ring sensor with a collocated MEMS accelerometer is considered. The system by which finger acceleration disturbs PPG output is identified and a means of modeling this relationship is prescribed using either FIR or Laguerre models. This means of modeling motivates the use of a recursive least squares active noise cancellation technique using the MEMS accelerometer reading as an input for a FIR or Laguerre model. The model parameters are identified and tuned in real time to minimize the power of the recovered PPG signal. Experiments show that the active noise cancellation method can recover pulse information from PPG signals corrupted with up to 2G of acceleration with 85% improvement in mean squared error.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.600781

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 41

Metadata

Authors
Gibbs, P. T., Wood, L. B., & Asada, H. H.
Venue
SPIE Proceedings
Publisher
SPIE
Published
2005-05-17
Volume
5765
Pages
811
ISSN
0277-786X (ISSN-L)
OpenAlex
W2080911522
Cited by
41
References
2
FWCI
1.55
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers. https://app.cochat.ai/papers/10.1117/12.600781
The paper
Gibbs, P. T., Wood, L. B., & Asada, H. H. (2005). Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers. SPIE Proceedings. https://doi.org/10.1117/12.600781

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.