Validation of a two‐ to three‐dimensional registration algorithm for aligning preoperative CT images and intraoperative fluoroscopy images
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present a validation of an intensity based two‐ to three‐dimensional image registration algorithm. The algorithm can register a CT volume to a single‐plane fluoroscopy image. Four routinely acquired clinical data sets from patients who underwent endovascular treatment for an abdominal aortic aneurysm were used. Each data set was comprised of two intraoperative fluoroscopy images and a preoperative CT image. Regions of interest (ROI) were drawn around each vertebra in the CT and fluoroscopy images. Each CT image ROI was individually registered to the corresponding ROI in the fluoroscopy images. A cross validation approach was used to obtain a measure of registration consistency. Spinal movement between the preoperative and intraoperative scene was accounted for by using two fluoroscopy images. The consistency and robustness of the algorithm when using two similarity measures, pattern intensity and gradient difference, was investigated. Both similarity measures produced similar results. The consistency values were rotational errors below 0.74° and in‐plane translational errors below 0.90 mm. These errors approximately relate to a two‐dimensional projection error of 1.3 mm. The failure rate was less than 8.3% for three of the four data sets. However, for one of the data sets a much larger failure rate (28.5%) occurred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Self-citation
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…et al. (2002), Jans et al. (2006), Khamene et al. (2006), Knaan and Joskowicz (2003), Munbodh et al. (2006, 2008, 2009), Nakajima et al. (2002), Penney et al. (1998, 2001, 2007), Roth et al. (1999), Russakoff et al. (2003), Russakoff et al. (2005a,b), Sirois et al. (1999), Rohlfing et al.…”
BackgroundMethodInfluentialMedical imaging at Guy's Hospital, King's College London
Hawkes, D. J., & Hill, D. L. G. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815866 · Cited by 260
Self-citationStandardized evaluation methodology for 2-D-3-D registration
van de Kraats, E. B., Penney, G. P., Tomazevic, D., van Walsum, T., & Niessen, W. J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.853240 · Cited by 211
Self-citationGradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
Livyatan, H., Yaniv, Z., & Joskowicz, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819288 · Cited by 176
A STUDY OF THE ACCURACY OF CYBERKNIFE SPINAL RADIOSURGERY USING SKELETAL STRUCTURE TRACKING
Ho, A. K., Fu, D., Cotrutz, C., Hancock, S. L., Chang, S. D., Gibbs, I. C., Maurer, C. R., & Adler, J. R. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000249248.55923.ec · Cited by 163
Russakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
McLaughlin, R. A., Hipwell, J., Hawkes, D. J., Noble, J. A., Byrne, J. V., & Cox, T. C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852067 · Cited by 63
Self-citationvan der Bom, I. M. J., Klein, S., Staring, M., Homan, R., Bartels, L. W., & Pluim, J. P. W. (2011) · SPIE Proceedings · doi:10.1117/12.877655 · Cited by 55
“with: Dv(i, j) = ∂IF (i, j) ∂i − sv ∂IDRR(i, j) ∂i , (4)”
Fully automated 2D–3D registration and verification
Varnavas, A., Carrell, T., & Penney, G. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.08.005 · Cited by 50
Self-citationEffective Intensity-Based 2D/3D Rigid Registration between Fluoroscopic X-Ray and CT
Knaan, D., & Joskowicz, L. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39899-8_44 · Cited by 43
Evaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
Gendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
(2009) · doi:10.1007/978-3-642-04268-3_46 · Cited by 32
“For the alignment of the CTA with the X-ray data, a rigid intensity-based registration framework is applied [7].”
MethodChen, X., Graham, J., Hutchinson, C., & Muir, L. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2226740 · Cited by 26
Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
van der Bom, M. J., Pluim, J. P. W., Gounis, M. J., van de Kraats, E. B., Sprinkhuizen, S. M., Timmer, J., Homan, R., & Bartels, L. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/010 · Cited by 21
Fully automated initialisation of 2D–3D image registration
Varnavas, A., Carrell, T., & Penney, G. (2013) · 2013 IEEE 10th International Symposium on Biomedical Imaging · doi:10.1109/isbi.2013.6556538 · Cited by 9
“Each DRR is then compared to the fluoroscopy image through the computation of a Gradient Difference Similarity Measure (GDSM) [6].”
MethodInfluentialSelf-citation
Metadata
- Authors
- Penney, G. P., Batchelor, P. G., Hill, D. L. G., Hawkes, D. J., & Weese, J.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 28
- Issue
- 6
- Pages
- 1024-1032
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1996672948
- Cited by
- 112
- References
- 2
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.