The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A method for the reconstruction of four‐dimensional synchronized CT scans acquired during free breathing
Abstract
Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity‐modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath‐hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four‐dimensional (4‐D) image set, where tidal lung volume is the additional dimension. An analysis of this 4‐D data leads to methods for digital‐spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4‐D image set is generated by sorting free‐breathing multislice CT scans according to user‐defined tidal‐volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital‐spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
The use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 912
Respiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 636
Measurement of three-dimensional lung tree structures by using computed tomography
Wood, S. A., Zerhouni, E. A., Hoford, J. D., Hoffman, E. A., & Mitzner, W. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.5.1687 · Cited by 162
Dynamic imaging of the upper airway during respiration in normal subjects
Schwab, R. J., Gefter, W. B., Pack, A. I., & Hoffman, E. A. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.4.1504 · Cited by 158
A dynamic analysis of chest wall motions with MRI in healthy young subjects *
Kondo, T., Kobayashi, I., Taguchi, Y., Ohta, Y., & Yanagimachi, N. (2000) · Respirology · doi:10.1046/j.1440-1843.2000.00221.x · Cited by 94
Cited by
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Self-citation4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
Overview of image-guided radiation therapy
Xing, L., Thorndyke, B., Schreibmann, E., Yang, Y., Li, T.-F., Kim, G.-Y., Luxton, G., & Koong, A. (2006) · Medical Dosimetry · doi:10.1016/j.meddos.2005.12.004 · Cited by 468
Acquiring 4D thoracic CT scans using a multislice helical method
Keall, P. J., Starkschall, G., Shukla, H., Forster, K. M., Ortiz, V, Stevens, C. W., Vedam, S. S., George, R., Guerrero, T., & Mohan, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/10/015 · Cited by 399
Rietzel, E., Chen, G. T. Y., Choi, N. C., & Willet, C. G. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.11.037 · Cited by 330
4D MR imaging of respiratory organ motion and its variability
Siebenthal, M. V., Székely, G., Gamper, U., Boesiger, P., Lomax, A., & Cattin, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/001 · Cited by 324
Correlation of lung tumor motion with external surrogate indicators of respiration
Hoisak, J. D. P., Sixel, K. E., Tirona, R., Cheung, P. C. F., & Pignol, J.-P. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.07.681 · Cited by 318
Motion in radiotherapy: particle therapy
Bert, C., & Durante, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/16/r01 · Cited by 315
Yamamoto, T., Langner, U., Loo, B. W., Shen, J., & Keall, P. J. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.06.1937 · Cited by 280
Enhancing Cardiac PET by Motion Correction Techniques
Rubeaux, M., Doris, M. K., Alessio, A., & Slomka, P. J. (2017) · Current Cardiology Reports · doi:10.1007/s11886-017-0825-2 · Cited by 48
Metadata
- Authors
- Low, D. A., Nystrom, M., Kalinin, E., Parikh, P., Dempsey, J. F., Bradley, J. D., Mutic, S., Wahab, S. H., Islam, T., Christensen, G., Politte, D. G., & Whiting, B. R.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2003-05-30
- Volume
- 30
- Issue
- 6
- Pages
- 1254-1263
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2133025770
- Cited by
- 475
- References
- 7
- FWCI
- 32.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.